52
13.
FWF Interval
–
FWF interval time (HH:mm:ss)
14.
PassiveUVoff
–
Time from leaving freshwater production to turning UV off (HH:mm:ss)
15.
UV off delay
–
Time from UV on to diversion valve to tank (HH:mm:ss)
16.
AutoStart Tank
–
Autostart on tank empty (yes or no)
17.
BP Delay
–
Time from feed pump to high pressure pump/ETD (HH:mm:ss)
18.
Salinity Level
–
Salinity error level (ppm)
19.
Min Pressure
–
minimum pressure (Bar or PSI)
20.
Min Pressure Time
–
Min pressure measure time (HH:mm:ss)
21.
Max Pressure
–
Maximum pressure (Bar or PSI)
22.
Sol. Valve Time
–
Solenoid valve time (seconds)
Configuration (Read) Menu
This menu monitors a selected list of configuration parameters, which may be of interest to
the operator (e.g. units are metric or US, FWF time interval, etc.). This menu is appended to
the Display Menu.
1.
Unit
–
units (metric or US)
2.
Low Pressure 1 Inst
–
S1 Lo pressure sensor installed (yes or no)
3.
Low Press 2 Inst
–
S2 Lo pressure sensor installed (yes or no)
4.
Prod Flow Inst
–
Product flow meter installed (yes or no)
5.
Brine Flow Inst
–
Brine flow meter installed (yes or no)
6.
Tank Full Inst
–
Tank level full sensor installed (yes or no)
7.
Tank Empty Inst
–
Tank level empty sensor installed (yes or no)
8.
Time to AutoShut
–
Auto shutdown after X hours in state FWP (HH:mm:ss)
9.
AutoShut Time
–
Auto shutdown after time (yes or no)
10.
AutoShut Tank
–
Auto shutdown on tank full (yes or no)
11.
FWF Duration
–
FWF duration time (HH:mm:ss)
12.
FWF Interval
–
FWF interval time (HH:mm:ss)
13.
AutoStart Tank
–
Autostart on tank empty (yes or no)
14.
Salinity Level
–
Salinity error level (ppm)
15.
Min Pressure
–
minimum pressure (Bar or PSI)
16.
Max Pressure
–
Maximum pressure (Bar or PSI)
17.
Sol. Valve Time
–
Solenoid valve time (seconds)
Fresh Water Flush button
This button initiates the Fresh Water Flush (FWF) cycle. The cycle can be interrupted by
pressing it again to stop operation. Note that this button starts the FWF cycle, regardless of
whether or not you are browsing a menu.
Booster Pump button
Start the booster pump. Press the Start/Stop button to stop operation. Note that this button
starts the booster pump, regardless of whether or not you are browsing a menu.
Содержание AQUA DUO - A455C
Страница 15: ...15 Figure 2 4 Piping and Instrumentation Diagram 2800 3600 GPD...
Страница 16: ...16 Figure 2 5 Piping and Instrumentation Diagram 2800 3600 GPD with Optional 20 Micron Prefilter...
Страница 17: ...17 Figure 2 6 Piping and Instrumentation Diagram 4800 6200 GPD...
Страница 18: ...18 Figure 2 7 Piping and Instrumentation Diagram 4800 6200 GPD with Optional 20 Micron Prefilter...
Страница 33: ...33 Figure 2 28 Hose Tube Connection Instructions Figure 2 29 Tubing Fitting Internals...
Страница 64: ...64 8 DRAWINGS DIAGRAMS...
Страница 65: ...65 1 P ID...
Страница 66: ...66...
Страница 67: ...67...
Страница 68: ...68...
Страница 69: ...69 2 GA Drawing...
Страница 70: ...70...
Страница 71: ...71...
Страница 72: ...72...
Страница 73: ...73...
Страница 74: ...74...
Страница 77: ...77 4 Wiring Diagrams...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80...
Страница 81: ...81...