45
1.
The feed water temperature is higher than 77º F/ 25º C.
2.
The feed water salinity is less than 35,000 PPM TDS (3.5% Total Dissolved Solids).
3.
The RO Membrane Element is new and on the plus 15% side of the specifications.
By monitoring feed water salinity, temperature and resulting system operating pressure, it is
possible to measure and monitor the fouling of the RO Membrane Element over time and use.
As the feed water vane pump becomes worn from normal use, it will lose flow and the ability to
build up pressure.