20
8903/RS RS485 Communications Interface
FB Input and Output Data Types
RS485 Data Types
Data Type
Description
Range
INT16
16-bit signed integer
-32,768 to 32,767
INT32
32-bit signed integer
-2,147,438,648 to 2,147,483,647
UINT16
16-bit unsigned integer
0 to 65,535
UINT32
32-bit unsigned integer
0 to 4,294,967,295
FLOAT
32-bit IEEE-754 floating-
point value
1.19209290e-38 to 3.438
Conversion of DSE Type < > RS485 Type
Each DSE register may have one of the RS485 data types described. This is the format that the
Modbus master will ‘see’. The fieldbus input and output connectors have one of three types:
logic, integer or value. DSE will automatically convert between the fieldbus connector type and
the register type (see
Appendix A: DSE/RS485 Conversion Rules
).
Some recommended RS485 type assignments to fieldbus connectors are given in the table
below.
Fieldbus Connector
RS485 Type
LOGIC UINT16
INTEGER UINT16
UINT32
INT16
INT32
VALUE FLOAT
Data Type
Description
Range
LOGIC
Logic
False (F) and True (T)
INTEGER
32-bit signed integer
-2,147,483,648 to 2,147,483,647
VALUE
32-bit fixed point value
-32768.0 to 32767.9999