7-2
Technical Specification
506/507/508 - HA389427
Adjustment Range
Parameter
Symbol Value
Units
Armature loss comp.
Maximum speed
Minimum speed
Ramp up time
Ramp down time
IR comp
N max
N min
Ramp
Ramp
0 - 25% of Va
100% ± 25%
0 - 25% of N max
1 - 15 (minimum)
1 - 15 (minimum)
%
s
s
Environmental Requirements
Operating Temperature
0 to +40
o
C (Derate 1.5% / Degree above 40
o
C)
Max. Operating Temperature 50
o
C
Humidity
85% R.H. at 40
o
C (non condensing)
Altitude
Above 1000m derate at 1% / 100m
Atmosphere Non-flammable,
non-corrosive and dust free
Storage Temperature Range -25
o
C to +55
o
C
Transport Temperature Range -25
o
C to +55
o
C
Enclosure
IP2X suitable for cubicle mounting
Installation Category
Overvoltage Category III.
Pollution
Pollution Degree 2.