Installing the 506/507/508
4-1
506/507/508 - HA389427
5
I
NSTALLING THE
506/507/508
Installation
Speed Control
Figure 4.1 Wiring Diagram Speed Control
MAINS
FILTER
L1
L2/N
GRD
Fuse
6
5
4
3
2
1
10K
I LIMIT
+ 10 V
SETPOINT
RUN
COMMON
TACHO GENERATOR
F +
F -
A -
A +
GRD
FF
F
A
AA
T6
Fuse
*
RUN
neutral
Double/reinforced insolation
potentiometer and run switch
boundary provided by users
* Additional line fuse recommended for applications where live
connections are made rather than live and netral.
'Run' connects to Common to 'Enable' Speed Control.
Current Control
Figure 4.2 Wiring Diagram Current Control
MAINS
FILTER
L1
L2/N
GRD
Fuse
6
5
4
3
2
1
10K
I LIMIT
+ 10 V
SETPOINT
RUN
COMMON
TACHO GENERATOR
F +
F -
A -
A +
GRD
FF
F
A
AA
T6
Fuse
*
RUN
neutral
10K
SPEED SETPOINT
Double/reinforced insolation
boundary provided by users
potentiometers and run switch
•
Optional Speed Setpoint potentiometer to limit overspeed, connect
setpoint direct to +10V if not required.
* Additional line fuse recommended for applications where live
connections are made rather than live and netrual
'Run' connected to +10V to 'Enable' Current Control and
'Override' Stall detection.
Содержание 506 Series
Страница 8: ...Contents Contents Page ...
Страница 10: ...1 2 Product Overview 506 507 508 HA389427 WWW SDS LTD UK 0117 9381800 ...
Страница 12: ...2 2 Overview of the 506 507 508 506 507 508 HA389427 ...
Страница 16: ...3 4 Terminal Description 506 507 508 HA389427 ...
Страница 29: ...4 14 Installing the 506 507 508 506 507 508 HA389427 ...
Страница 31: ...5 2 Routine Maintenance and Repair 506 507 508 HA389427 ...