Terminal Description
506/507/508 - HA389427
Power Terminals
The product may be connected phase - to - phase provided the resultant
voltage does not exceed the maximum supply voltage specified.
Terminal Function
Description
Notes
L1 (L)
AC Input Live
AC Supply Terminal Line 1
or Live
L2 (N)
AC Input Neutral
AC Supply Terminal Line 2
or Neutral
F+
Field Positive
Field Output Positive
F-
Field Negative
Field Output Negative
A-
Armature Negative
Armature Output Negative
A+
Armature Positive
Armature Output Positive
Grd
Protective Earth (Ground) Drive Module Protective
Earth (Ground)
Grd
Protective Earth (Ground) Motor Protective Earth
(Ground)
Auxiliary Terminals
* The power must be supplied from an independent power supply
which is not earth (ground) referenced.
Terminal Function
Description
Notes
A1
Auxiliary Supply
Auxiliary Relay Supply +16V at 10mA
A2
0V - Signal Common Signal Reference
Must not be earthed
(grounded)
A3
Zero Speed
Zero Speed Output
24V at 50mA open
Collector *
A4
Health
Health Output
24V at 50mA open
Collector *
A5
Zero Speed Level
Zero Speed Output
Level Trim
For other levels see
Table 3.1
A6
Auxiliary Setpoint
Auxiliary Direct Speed
Setpoint
+10V @ 100K Full
Speed Input
Содержание 506 Series
Страница 8: ...Contents Contents Page ...
Страница 10: ...1 2 Product Overview 506 507 508 HA389427 WWW SDS LTD UK 0117 9381800 ...
Страница 12: ...2 2 Overview of the 506 507 508 506 507 508 HA389427 ...
Страница 16: ...3 4 Terminal Description 506 507 508 HA389427 ...
Страница 29: ...4 14 Installing the 506 507 508 506 507 508 HA389427 ...
Страница 31: ...5 2 Routine Maintenance and Repair 506 507 508 HA389427 ...