Microfilter for 

Technical Gases 

 

TGA 104–118, 

16–50 bar 

TGH 104–118, 

 100–450 bar 

TGS 214–232, 

16–100 bar 

TGE 308–326, 

16–100 bar

   

 

 

 

 

 

 

 

 

 

Operating Instructions 

 

 

 

 

 

 

 

Revision 01—2016/ EN 

398H271902 

 

 

Содержание PURGAS TGA1 Series

Страница 1: ...Microfilter for Technical Gases TGA 104 118 16 50 bar TGH 104 118 100 450 bar TGS 214 232 16 100 bar TGE 308 326 16 100 bar Operating Instructions Revision 01 2016 EN 398H271902...

Страница 2: ...N_01 2016 Type Label Attach type label here Heed the data on the type label and keep it readable at all times Note The operator is responsible if an acceptance of the overall system as per ATEX should...

Страница 3: ...your own safety 6 Assembly Drawings 9 Storing filters and filter elements 13 Filter installation 14 Maintenance intervals and work 16 Correcting faults 22 Technical information 23 Spare parts and opt...

Страница 4: ...omic operation of filter series TGA1 TGH1 TGS2 and TGE3 for technical gases Layout conventions Work steps that you have to carry out in the sequence stated are marked by black triangles Lists are mark...

Страница 5: ...es The staff have basic experience in handling pneumatic devices Notes on handling operating instructions These operating instructions must be continuously available at the site where the filter is us...

Страница 6: ...e 2 only ATEX compliant filters are conductive The operator must make sure conductivity is maintained under all circumstances He must also make sure that the conductivity is not impaired by any attach...

Страница 7: ...up the filter s surfaces Do not touch hot surfaces Wait until the surfaces have cooled down before starting work on the filter Safety notes on specific operating phases Notes on critical gases All ex...

Страница 8: ...den pressure fluctuations on pressure build up and de pressurization If the pressure builds up or drops too quickly this may cause damage to the filter When using accessories with an external power su...

Страница 9: ...Filter element O ring 4 Housing O ring 5 Threaded rod 6 Filter element 7 Lower housing 8 16 bar Manual drain HV01 TG 25 50 bar Manual drain EV05 TG 16 bar ATEX Manual drain EV05 TG Optional A Differe...

Страница 10: ...1 Locking screw 2 O ring 3 Upper housing 4 Threaded rod 5 Filter element O ring 6 Filter element 7 Housing O ring 8 Lower housing 9 Double nipple 10 Manual drain EV05 TG Optional A Differential press...

Страница 11: ...2 Flat seal housing 3 Filter element 4 Manual drain EV05 TG through EV08 TG 5 Lower housing Optional A Differential pressure gauge HZD80 50RTGF with connection pipes B Earthing lug and connection bore...

Страница 12: ...king screw 2 Upper housing 3 Filter element 4 Housing O ring 5 Lower housing 6 Lock ring 7 Double nipple 8 Manual drain EV05 TG Optional A Differential pressure gauge HZD80 50RTGS with connection pipe...

Страница 13: ...of dust or the filter must be packed dustproof The storage space must feature an ambient temperature of at least 1 C Caution When you want to store the filter for a longer period e g several months yo...

Страница 14: ...he permissible gas temperature must be available This safety device must prevent that limit values are exceeded A suitable pressure relief device and a condensate drain must be installed for the filte...

Страница 15: ...application When installing differential pressure gauge HZDE80 Establish electrical connection Re pressurize pipe section and check for leaks When installing a filter with TKM or TKA cartridge Beware...

Страница 16: ...he pipe section in question with inert gas have the notes on hazardous substances for the used gas ready take appropriate protection measures verify the absence of an explosive atmosphere Maintenance...

Страница 17: ...t regular intervals and properly dispose of it Clean filter ATEX compliant filters Dust that has collected on the filter can pose a potential risk It is therefore vital to regularly clean the filter T...

Страница 18: ...en ended spanner to the square at the housing bottom Use a similarly suitable tool e g a strap wrench if an open ended spanner cannot be used Apply the tool clearly below the thread TGA and TGH filter...

Страница 19: ...s as described in section Preparations on page 17 Unscrew and remove the nuts on the lower housing Remove the lower housing or swing it aside Remove flat seal Unscrew and remove the filter element Ins...

Страница 20: ...Ensure conductivity test and document it Check the housing for tightness Replacing the cartridge of TGA and TGH filters Note on intervals The operating conditions of cartridges with their respective...

Страница 21: ...ibed in section Preparations on page 17 Open the filter at regular intervals e g every 6 months Check whether the threads are still sufficiently greased and well running Apply a thin coat of grease on...

Страница 22: ...ves if necessary cancel the EX zone first Start work only then All gases Block gas supply to the filter Depressurise the filter housing Make sure the pressure has been positively relieved Allow filter...

Страница 23: ...GA 112 G 1 130 406 43 235 4 5 4 1 4 1 TB 20_ TGA 114 G 1 1 2 130 506 43 335 5 0 4 9 4 9 TB 30_ TGA 116 G 1 1 2 130 706 43 525 6 4 5 0 5 0 TB 50_ TGA 118 G 2 164 751 48 520 9 6 6 6 6 6 TC 50_ TGH 104 1...

Страница 24: ...ns mm Weight kg Element A B C D TGE 308 depending on the medium upon request G 3 4 151 300 55 85 3 0 TE 09_ TGE 314 G 1 1 2 198 400 75 140 4 2 TE 13_ TGE 316 G 2 233 570 80 280 7 1 TE 14_ TGE 320 G 2...

Страница 25: ...F elements Filtration degree depends on the element type c for TGA1 and TGH1 series only Spare parts and options Spare part ordering Please specify the correct order code see the filter designation on...

Страница 26: ...A 116 TGA 118 16 bar TGA 110 TGA 118 16 bar 50 bar TGA 112 TGA 118 25 bar TGH 110 TGH 118 100 bar 450 bar TGA 110 TGA 118 50 bar TGH 104 TGH 108 250 bar 350 bar TGH 110 TGH 118 100 bar 450 bar TGE 314...

Страница 27: ...ent directive 2014 34 EU is not required Production is subject to the ZANDER Management System and was subjected to a conformity assessment as per Appendix III module B The modules as per Art 4 No 3 a...

Страница 28: ...any GmbH Co KG Gas Separation and Filtration Division EMEA Im Teelbruch 118 D 45219 Essen Internet www parker com hzd E Mail zander parker com Telefon 0049 0 2054 934 0 Fax 0049 0 2054 934 164 A Divis...