Note:
It is not possible to completely close the regeneration air setting
valve.
► The required regeneration gas volume is set by turning the regeneration gas
screw in accordance with the following table.
► Count the half and full turns of the setting screw till the required set value is
reached.
► Secure the setting by tightening the lock nut.
► If no other maintenance work is to be carried out: Restart the dryer (see
page 36).
Turns
Output at 100 bar
Output at 350 bar
m³/h
m³/h
0
1.0
1.0
0.5
1.7
3.4
1
2.2
5.7
1.5
2.8
8.1
2
3.3
10.5
2.5
3.9
12.8
3
4.4
15.2
3.5
5.0
17.5
4
5.5
19.9
4.5
6.1
22.3
5
6.7
24.6
5.5
7.2
27.0
6
7.8
29.3
6.5
8.3
31.7
7
8.9
34.1
7.5
9.4
36.4
8
10.0
38.8
8.5
10.5
41.1
9
11.1
43.5
9.5
11.6
45.9
10
12.2
48.2
10.5
12.7
50.6
11
13.3
52.9
11.5
13.8
55.3
12
14.4
57.7
Table: Regeneration gas volume setting (reference values)