Page 26/71
Padlock command 116
J.
Remove the maintenance card from the reader.
K.
Operate the bolts with the square key. Open the maintenance door and hold the bolts in raised position
for a few seconds until the electronic lock actuator gets back in position (the operator hears a spring
noise).
Holding the bolts in raised position with the square key for a few seconds after opening the door is
necessary to avoid some technical issues associated with an incorrect repositioning of the electronic lock
actuator.
6.1.2.2
Closing the maintenance door
A.
Select the
Padlock command
function of the
Maintenance
menu (function
116
).
The terminal displays a message prompting maintenance door closing.
B.
Close the maintenance door and operate the bolts with the square key.
When the terminal detects that the door is closed, it is automatically locked.
If the maintenance menu is activated, select the Cancel function to trigger the locking function and leave
the maintenance menu.
6.2
Opening / closing the maintenance door with a mechanical lock
6.2.1
Preliminary operations
A.
Take:
the maintenance door mechanical key (degraded mode),
the Parkeon door opening tool, to prevent damage to the housing or door paint,
a square key,
a maintenance card with adapted access rights.
6.2.2
Procedure (normal mode)
6.2.2.1
Opening the maintenance door
The electronic lock is equipped with protective flaps to reduce the risk of vandalism.
A.
Insert the tip of the door opening tool (2) in the lock (3).
B.
With the tip of the tool, push the first protective flap to the left (4) and the second flap to the right (5).
C.
When the keyholes are reachable, insert the square key (1) in its slot.