background image

2

IMPORTANT NOTES

The Ultra UV2 replacement tank is assembled with pressure switch, mounting plate, quartz tube, main 
seal, compression washer & sealing nut. All replacement tanks are pressure tested at the factory.
The Ultra UV2 tank also includes ballast input wires for several build configurations. 
Not all wires included in kit will be used.

On 230V units the existing conduit & power supply wires may be too short and need to be 
replaced.

INSTALL THE REPLACEMENT TANK
1.  Remove the three bonnet screws & lift bonnet 

from old tank. The bonnet, screws, and 
washers will be used for the new tank.

2.  Disconnect the grounding wire from the 

bonding lug.

3.  Loosen the plumbing unions (two unions for 

1-lamp & 2-lamp builds, and four unions for 
3-lamp builds).

4.  Remove the old Ultra UV2 unit from the 

mounting location and set carefully aside.

NOTE: If in operating condition, the ballast & 
lamps from the old unit will be re-installed.

5.  Us ing ABS cement, install the supplied 

blanking plugs & unions to the new 
replacement tank. 
• Be sure to match the placement of fittings 
on the old tank. 
• Note the orientation of the incoming 
electrical supply.

6.  Place the new replacement tank at the 

mounting location.

7.  Tighten the unions securely (do not over-

tighten).

8.  Reconnect the grounding wire to the bonding lug.

Allow the ABS cement to cure 
for a minimum of one hour. 

 CAUTION

Do not stand over the unit when 

it is under pressure or when the 

pump is on.

 CAUTION

9.  Turn on power to the pool pump and verify no 

leaks are found at the new tank.

Turn off power to the pool 
pump before proceeding

 DANGER

Turn off the power supply to the old Ultra UV2 unit. Turn off power to the pool pump. 
Disconnect the input power to the installed Ultra UV2:
• For 120v units unplug the supply cord from the GFCI.
• For 230v units disconnect the incoming power wires & conduit.

 DANGER

Bonding Lug

Do not touch the glass part 
of the lamp or quartz tube 
with bare hands as body oils 

will create hot spots & greatly shorten lamp life. 
Always wear gloves.

NOTICE

Содержание Ultra UV2

Страница 1: ...ALLATION GUIDE IN ITS ENTIRETY AND HEED ALL SAFETY INFORMATION Failure to follow these instructions and warnings can result in DEATH OR SERIOUS INJURY DANGER CAUTION indicates a hazardous situation wh...

Страница 2: ...be re installed 5 Us ing ABS cement install the supplied blanking plugs unions to the new replacement tank Be sure to match the placement of fittings on the old tank Note the orientation of the incomi...

Страница 3: ...Remove metal disk from the old quartz tube and place it gently into the new quartz tube Note Dropping metal disk into quartz tube may cause damage 6 Install the lamps into the quartz tube in the new...

Страница 4: ...and pull gently until wire is disconnected 2 Remove ballast s from the old tank and install onto the integrated brackets on the new tank with the wire input side facing the pressure switch 3 Disconne...

Страница 5: ...wires behind terminal block 4 Using one of the green ground wires D connect it to the right ground post Make sure the flat washer is underneath the ring terminal of the green wire 5 Connect all the c...

Страница 6: ...wires at the junction of the conduit connector Reinstall the grommet to the mounting plate 3 Cut the ground wire to length and attach an 18 22 AWG ring terminal Remove the nut from the left ground po...

Страница 7: ...s Y connector quartz tube quartz tube o ring compression washer 2 union kit 6 blanking plugs 2 005 422 3000 00 Ultra UV Tank Replacement 120V Includes Wires Y connector quartz tube quartz tube o ring...

Страница 8: ...8...