background image

LT5245 (2:02/09)

 

 

 

Paragon Symphony CF 

Users Instructions 

 

SECTION ONE 

Introduction Continued

 

 

The PARAGON SYMPHONY CF is battery operated; therefore no mains electrical supply is required. 
Power to the appliance is provided by 6 high power alkaline 1.5V batteries (AA size) (a spare set of 6 
AA batteries is supplied with the appliance); these batteries can be changed to Nickel Metal Hydride 
rechargeable batteries providing they have a minimum capacity of 2200 mAh. A set of 6 high power 
alkaline 1.5V batteries (AA size) would give in the order of 200 -380 operations while 6 rechargeable 
batteries  when  fully  charged  would  give  approximately  200-300  operations.  These  figures  are  only 
given  for  guidance  and  may  vary  depending  on  how  the  appliance  is  used  and  the  battery 
manufacturer and quality.   
 
A special long life lithium battery is available as an optional extra and would be expected to give in 
excess  of  12  months  normal  use  (a  minimum  of  1000  operations),  however  it  is  not  subject  to  the 
guarantee. For more information call the telephone number located on the back of this booklet. 
Using the standby facility when the appliance is switched off for short periods can extend battery life. 
The standby facility switches off the mains gas supply to the appliance but the pilot remains alight.  
 
An audible double bleep warning indicates that the appliance batteries need changing or charging (if 
rechargeable batteries have been used).  

Important:  Batteries  should  be  changed  or  recharged  as  soon  as  possible  as  the  appliance 
will not light if the battery power gets to low.  

 
IMPORTANT INFORMATION 

• 

The appliance is for use on Natural Gas (G20 @ 20mbar) only.  

• 

The chimney or flue (unless new or previously used with a gas appliance) shall be swept before 
installation if it has been used for solid fuel. 

• 

The fire front (fret) or fascia supplied must be used with this appliance.  

• 

Failure to install appliance correctly could lead to prosecution. 
In GB (Great Britain), the appliance must be installed by a competent person i.e. CORGI-
registered, in accordance with the GAS SAFETY (INSTALLATION AND USE) REGULATIONS, 
The Building Regulations (or The Building Regulations (Scotland) or The Building Regulations 
(Northern Ireland)) and The Current I.E.E. Wiring Regulations, if appropriate.  
In IE (Ireland), the appliance must be installed by a competent person and installed in accordance 
with the current edition of I.S.813 Domestic Gas Installation, the current Building Regulations and 
the current ETCI rules for electrical installation, if appropriate.   

• 

The  glass  front  of  this  fire  acts  as  a  dress  guard,  conforming  to  BS  1945  (1997)  however;  a 
fireguard  conforming  to  BS6539  (1997)  must  be  used  to  protect  young  children,  the  elderly  or 
infirm.   

• 

The  appliance  MUST NOT be  used  with  the  glass  safety  screen  removed or  if  it  is damaged  or 
cracked. 

• 

During  initial  firing,  an  odour  may  be  evident.  This  is  the  starch  binder  used  during  the 
manufacture of the fibre components of the fire, and there are 

no harmful

 effects produced. 

• 

During the normal operation of the fire some black staining may appear on some parts of the fuel 
bed.  This  is  quite  normal  and  adds  to  the  appearance  of  the  appliance.  However,  if  excessive 
black  staining  does  occur  it  may  be  due  to  the  fuel  bed  being  incorrectly  laid.  This  should  be 
checked prior to contacting a service engineer. 

 

Содержание SYMPHONY CF

Страница 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IRELAND only A QUALITY PRODUCT FROM PARAGON FIRES PARAGON FIRES TELFORD SHROPSHIRE TF7 4QJ ...

Страница 2: ... Fuel Bed Layout 9 SECTION FIVE General Points 12 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 12 SECTION SEVEN Regulations and Warnings 13 SECTION EIGHT Siting the Appliance Flue Class1 14 SECTION NINE To Install Appliance Checking the Flue and Fire Opening 14 Gas Supply Routing 15 Glass Removal 15 Connecting to the Gas Supply 15 SECTION TEN Checking Fire Operation Check Gas soundness 16 ...

Страница 3: ...als or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial w...

Страница 4: ...gets to low IMPORTANT INFORMATION The appliance is for use on Natural Gas G20 20mbar only The chimney or flue unless new or previously used with a gas appliance shall be swept before installation if it has been used for solid fuel The fire front fret or fascia supplied must be used with this appliance Failure to install appliance correctly could lead to prosecution In GB Great Britain the applianc...

Страница 5: ...e pilot is alight the appliance will automatically go to the high setting approximately 20 25sec b If the ignitor stops sparking and the pilot fails to light press the button before repeating this procedure c The appliance can be adjusted up or down by pressing the appropriate button low setting or high setting These buttons have a duel function If they are pressed until a bleep is heard and then ...

Страница 6: ...2200mAh A long life lithium battery is available as an optional extra call the number shown on the last page of these instructions for further information a Lift off fret and ash pan b The battery power pack or holder is located at the left hand side of the burner carefully slide the battery holder forward and replace the six high power alkaline AA batteries as a complete set or recharge as approp...

Страница 7: ... this may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary to clean the glass panel of your Symphony CF fire We recommend you use a Ceramic hob cleaner these are available for all leading super markets i e ASDA TESCO SAINSBURY S Etc Brands of hob cleaning we...

Страница 8: ...ts provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on page 3 of this booklet before cleaning or replacing any refractory material The fuel bed components are delicate and they should be handled with great care The loose parts and moulded shapes may be rem...

Страница 9: ... the front edge of the burner Lay a thin layer of vermiculite over the burner top taking special attention to prevent blocking the pilot head assembly Lay a cover of cerrowool over the burner by tease out the fibre until they form a very loose very light network Try to ensure that clumps of fibre are not formed A loose net will allow gas to pass through them and ensure the maximum glow is attained...

Страница 10: ... 2 02 09 Paragon Symphony CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Position log shapes 3 and 4 as shown Position log shapes 5 and 6 as shown Position log shapes 7 and 8 as shown ...

Страница 11: ...ion inside the firebox will occur adding to the realism of the appliance This is normal It is important that The chimney or flue is checked annually to ensure clearance of combustion products The fire front or fascia must be positioned in front of the fire whilst it is burning Any debris from the chimney or flue should be removed The fire should be allowed to cool before it is removed The fire mus...

Страница 12: ...line or 6 x 1 5 V Rechargeable nickel metal hydride with a minimum capacity of 2200mAh A special long life lithium battery 7 2 V is available as an optional extra Appliance Dimensions NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2002 and the result is 80 The gross calorific value of the fuel has been used for this efficiency calculation GasTec have certified the...

Страница 13: ...ccordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if appropriate Prior to the installation ensure that the local distribution conditions identification of type of gas and pressure and adjustment of the appliance are compatible G20 20mbar IMPORTANT NOTE The fire front fret or fascia supplie...

Страница 14: ...duction of natural draught Ensure that the air entrering the appliance below the lower edge of the decorative trim is not restricted If the appliance is fitted above a forward projection hearth the base of the opening must be at least 50mm above the hearth Again this will ensure that the air entering the appliance below the lower edge of the decorative trim is not restricted CHECKING THE FLUE AND ...

Страница 15: ... three fixing the carrier to burner plate Remove the rubber blind grommet from the supply pipe inlet hole at the rear of the outer box and slide the box over the supply pipe and fix to the surround using one of the methods described in the next section Refit the grommet over the pipe and seal around the inlet hole Refit the burner unit and make connection between the supply isolating valve and the...

Страница 16: ... use fuel bed component provided for this appliance In the interest of safety and efficiency of your appliance when replacing the fuel bed it is essential that the existing fuel bed be removed and the new components are replaced correctly as a complete set Lay fuel bed as described under Users Section Warning It is important that the fuel bed components are positioned as shown in these instruction...

Страница 17: ...ER THAT The glass front of this fire acts as a dress guard conforming to BS 1945 1997 and satisfies the heating appliance regulations 1991 however a fireguard conforming to BS6539 1997 must be used to protect young children the elderly or infirm The curing effect of heating the logs and other refractory components will cause an initial odour This is due to the starch used in the manufacturing proc...

Страница 18: ... isolating cock Remove the trim fascia and glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Detach remote control eye from the fixing bracket See Section Nine when repositioning Disconnect fire at inlet elbow and Undo the five burner tray fixing screws Pull carefully forward and remove For normal servicing the tray can be cleaned using a v...

Страница 19: ... of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the pilot shield oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Follow the burner tray removal sequence Disconnect leads from control unit and remove 4 bolts Re assemble in the reverse order Turn on the gas supply check for gas soundness and re commission appliance FLUE ...

Страница 20: ... must be installed by a CORGI registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a CORGI registered person 4 The service log must be correctly filled out and the record of annual services must be up to date and supported by receipts in each case 5 This warranty is not transferable and relates to the original install...

Страница 21: ...______________ ___________________________________________ Date of Purchase Service Log The following information must be complete and supported by receipts as part of the conditions of the extended three year parts warranty and the appliance must be registered by completing and returning the registration document last page of this booklet to Paragon Fires Date of First annual service Engineer Nam...

Страница 22: ...DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHO E o PRODUCT DETAILS Model PARAGON SYMPHONY CF Serial No Date of Purchase This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim WHERE DID YOU PURCHASE THIS PRODUCT Name ___________________________...

Страница 23: ...23 LT5245 2 02 09 ...

Страница 24: ...all 2 bags Grommet 1092 1 X Bag of Vermiculite 4216 Glass Panel Air Tray 5183 Silicone Sealing Strip 4818 Symphony CF Inner Fascia 5230 Symphony CF Trim 5232 Battery 9V PP3 Remote Control Hand Set Battery Holder Battery Insulation Blanket AA Battery 12 Magnet 4 X Segment 3048 Owners Book Data Badge NG Located behind trim Warning Label 1409 ID Label Packing Labels Serial Number Inspector ...

Отзывы: