Paragon P7 Скачать руководство пользователя страница 26

26 

LT6757 ( Iss 1 06/14 )

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание P7

Страница 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IRELAND only Paragon Fires Charlton Jenrick LTD Telford Shropshire TF3 3AR ...

Страница 2: ...yout 8 SECTION FIVE General Points 11 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 12 SECTION SEVEN Regulations and Warnings 13 SECTION EIGHT Siting the Appliance Flue Class1 14 SECTION NINE To Install Appliance Checking the Flue and Fire Opening 15 Gas Supply Routing 15 SECTION TEN Checking Fire Operation Check Gas soundness 17 Checking Product Clearance 18 Advice To Customer 18 MAINTENAN...

Страница 3: ... for cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disp...

Страница 4: ...tent person i e GAS SAFE registered in accordance with the GAS SAFETY INSTALLATION AND USE REGULATIONS The Building Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Do...

Страница 5: ...ted up or down by pressing the appropriate button low setting or high setting These buttons have a duel function If they are pressed until a bleep is heard and then released immediately the appliance will automatically go to the maximum or minimum settings On the other hand if the button is not released gradual adjustment is made until the button is released or until the maximum or minimum setting...

Страница 6: ...ng life lithium battery is available as an optional extra call the number shown on the last page of these instructions for further information a Lift off the outer trim or Inlet Cover b The battery power pack holder is located on the right hand side on the base of the Firebox or within the fireplace frame assembly WARNING batteries will overheat if fitted incorrectly when fitting the batteries ens...

Страница 7: ...ner It is advisable not to blow the debris into the hole as this may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly P7 Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Before you clean any part of the appliance ensures that the appliance is turned off and cold Use only the fuel bed components prov...

Страница 8: ...ions SECTION FOUR Fuel Bed Cleaning and Layout Log Fuel bed Place air tray within burner shelf assembly Place three of the log shapes along the back edge of the air tray assembly as shown Place single layer of large bark chippings as shown ...

Страница 9: ...9 LT6757 Iss 1 06 14 P7 Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place two log shapes as shown Place two log shapes as shown ...

Страница 10: ...10 LT6757 Iss 1 06 14 P7 Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place two log shapes as shown Place two Log shapes as shown ...

Страница 11: ...ducts This can be inspected by removing the Flue Adaptor Assembly from the top of the fire box assembly Remove the log fuel bed shapes Remove the inner fascia and out trim at this stage Four Sided Trim Option Bend down the finger folds LH RH hand side located within glass canopy fixing bracket Very carefully remove the canopy side liners LH and RH Remove the three M4 nuts retaining the glass canop...

Страница 12: ...V AA high power alkaline Appliance Dimension NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 60 2 The gross calorific value of the fuel has been used for this efficiency calculation Gastec have certified the test data from which it has been calculated The efficiency value may be used in the UK Government s Standard Assessment Procedur...

Страница 13: ...nd The appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if appropriate Prior to the installation ensure that the local distribution conditions identification of type of gas and pressure and adjustment of the appliance are...

Страница 14: ...reviously been used with a gas appliance or if it is a new installation Note A brick or stone chimney with a 125 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the opening into the liner Ensure a smooth lead into the flue way and no combustible materials are used A void o...

Страница 15: ...the plasterboard and the wall is sealed with a suitable non combustible material i e plaster or mortar GAS SUPPLY ROUTING Use rigid or semi rigid tube to connect the supply Determine the gas supply pipe route to the appliance before installing the fire Fixing Firebox Assembly Slide the firebox into the fireplace open guiding the gas supply pipe through the hole at the rear LH bottom of the firebox...

Страница 16: ...ixing screws provide Connect battery pack as described in section 2 Operating the appliance Locate the battery pack in the holder positioned within the fireplace frame Inset the inlet Cover within the fireplace frame Operate the handset as described in section one Lay the fuel bed as described in section four Four Sided Trim Option Fit Air tray assembly and lay fuel bed as described in section fou...

Страница 17: ... isolation valve Disconnect the pressure gauge and replace the pressure test point screw Turn on the supply to the appliance and check the pressure test point for soundness with detection fluid Refit the gas connection cover Fit the air tray within the location with the burner shelf LAY FUEL BED Important Refer to the Heath Safety Notice located on page 3 of this booklet before laying or replacing...

Страница 18: ...ire is installed ADVISE CUSTOMER THAT The glass front of this fire acts as a dress guard conforming to BS 1945 1997 and satisfies the heating appliance regulations 1991 however a fireguard conforming to BS6539 1997 must be used to protect young children the elderly or infirm The curing effect of heating the logs and other refractory components will cause an initial odour This is due to the starch ...

Страница 19: ...R TRAY Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Remove gas supply cover Disconnect fire at inlet elbow and Undo the three burner tray fixing screws Pull carefully forward and remove For normal servicing the tray can be cleaned using a vacuum cleaner Whilst the tray is removed va...

Страница 20: ...pression nut on the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the pilot shield oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Follow the burner tray removal sequence Disconnect leads from control unit and remove 2...

Страница 21: ...up to date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registration Form must be correctly filled out and returned 7 The appliance has not been subjected to misuse or accident or been modified or repaired by any person other than the authorised employee or authorised representative of Charlton and Jenrick Ltd 8 The ...

Страница 22: ...te of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date of Fourth annual service Engineer Name Gas Safe Registration No We may introduce modifications to products from time to time and consequently the details given in this booklet are subject to a...

Страница 23: ...23 LT6757 Iss 1 06 14 ...

Страница 24: ...3AR YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model P7 Serial No Date of Purchase This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim WHERE DID YOU PURCHASE THIS PRODUCT Name ________________________________ A...

Страница 25: ...25 LT6757 Iss 1 06 14 ...

Страница 26: ...26 LT6757 Iss 1 06 14 ...

Страница 27: ...27 LT6757 Iss 1 06 14 ...

Страница 28: ...Adaptor Assy 6700 Air Tray 6698 Silicone Sealing Strip 4818 AA Battery 12 Remote Control Hand Set 6598 Additional Fixings A 0411 Battery Holder 4490 7mm Nut Spinner 2 x AAA Battery 5487 Owners Book Data Badge Warning Label 1053 ID Label Packing Labels P7 Log Set 6708 Ceramics 6703 6704 6705 6706 6707 Self Adhesive Clip 3133 Remote Reference Card 6713 Serial Number Inspector ...

Отзывы: