(800) 471-8769
13
Copyright 2021 © Paragon Tank Truck Equipment
• A proper maintenance program will keep your P657 blower in top running condition. A newly installed P657 blower
should be checked frequently during the first month of operation.
Use only Paragon Blower Oil.
Check oil levels and
add as needed.
• An oil analysis program is recommended.
- In the absence of an oil analysis program, change oil in both tanks every 500 hours.
Note:
Correct Oil Level is 1/2 to 7/8 full on the sight glass (See Fig. 6-Page 12). Air bubble must be visible at the top
of sight glass.
Daily
1.Check and maintain oil levels, add oil as necessary.
2.Check Air Filter restriction indicator.
Weekly
1.Check and maintain oil levels, add oil as necessary.
2.Check Air Filter restriction indicator.
Monthly
1.Inspect the entire system for leaks.
2.Inspect condition of oil and change if necessary.
Semi-Annually
1.Inspect the PTO components.
2.Use an oil analysis program.
Preventative Maintenance