background image

VIKING   Model VIV600

CAUTION

1. For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3. Your blower motor has a thermal overload which will automati-

cally shut off the motor if it becomes overheated. The motor
will restart when it cools down. If the motor continues to shut
off and restart, have the hood serviced.

4. Please read specification label on product for further informa-

tion and requirements.

Blower Dimensions

22.284 x 10.562 x 10.257

For use with Hood Models: VWH2448, VWH3048, VWH3648, VWH4248, VWH3078, VWH3678,

VWH4278, VIH3608, VIH4208, VBCV3038, VBCV3638, VBCV4238, VICV3698,VICV4298,

DTWN3048, DTWN3648, DTWN4248, DTWL3048, DTWL3648, DTWL4248

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manu-

facturer. If you have questions, contact the manufacturer
or your distributor.

2. Before servicing or cleaning unit, switch power off at ser-

vice panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, se-
curely fasten a prominent warning device, such as a tag,
to the service panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.

4. Sufficient air is needed for proper combustion and ex-

hausting of gases through the flue (chimney) of fuel burn-
ing equipment to prevent backdrafting. Follow the heat-
ing equipment manufacturer’s guidelines and safety stan-
dards such as those published by the National Fire Pro-
tection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. Do not use this unit with any solid-state speed control

device.

8. To reduce the risk of fire, use only steel ductwork.

9. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when

cooking flaming foods.

3. Clean ventilating fans frequently. Grease should not be al-

lowed to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for

the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,

or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi-
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.

3. DO NOT USE WATER, including wet dishcloths or towels

- violent steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher and

you already know how to operate it.

B. The fire is small and contained in the area where it

started.

C. The fire department is being called.

D. You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

Содержание VIV600

Страница 1: ...g Follow the heat ing equipment manufacturer s guidelines and safety stan dards such as those published by the National Fire Pro tection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must ...

Страница 2: ...ve wiring cover Run power cable to installation location remove knockout from rough in plate wiring box and connect cable to wiring box using proper connector Connect black to black white to white and green or bare wire under second ground screw Replace wiring cover Inside top of hood Blower plate Black to Black White to White Green to Green or Bare Wire or under ground screw Wing Nut Barrel Nut K...

Страница 3: ...z toujours la hotte en fonction ON lors de la cuisson à haute température ou lors de la cuisson d aliments à flamber 3 Nettoyez fréquemment les ventilateurs Ne laissez pas la graisse s accumuler sur le ventilateur ou le filtre 4 Utilisez des casseroles de dimension appropriée Utilisez toujours une batterie de cuisine adaptée à la dimension des éléments de surface AVERTISSEMENT OBSERVEZ LES CONSIGN...

Страница 4: ... vers l emplacement de pose Retirez l entrée sectionnable de la plaque de raccordement duboîtierdecâblageetbranchezlecâbleauboîtierdecâblage en utilisant le connecteur approprié Branchez les fils noirs ensemble les fils blancs ensemble et placez le fil vert ou lefildénudésousladeuxièmevisdebornedeterre Replacez le couvercle du boîtier de câblage Intérieur haut de la hotte Plaque du ventilateur Noi...

Отзывы: