2. INSTALL BLOWER PLATE
Attach
blower plate
to the studs at the
inside, top of
hood
with (4)
#10-24 nuts
, provided.
Blower plate
7" round
Inside, top
of hood
#10-24 nuts
(2 per side)
3. INSTALL DUCTWORK
Run 7" round steel duct to installation location.
Connect duct to rough-in plate. Use duct tape to make all
joints secure and air tight.
99043129D
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
1. CONNECT WIRING
Remove wiring cover.
Run power cable to installation location, remove knockout
from rough-in plate wiring box and connect cable to wiring
box using proper connector. Connect
black to black
,
white to white
, and
green or bare wire
under second
ground screw. Replace wiring cover.
Inside, top
of hood
Blower plate
Black to Black
White to White
Green to Green
or Bare Wire or
under ground
screw
Wing Nut
Barrel Nut
Keyhole
4. INSTALL BLOWER
Hang blower onto blower plate. Engage (2)
barrel nuts
into small ends of
keyholes
. Tighten barrel nuts and
wing
nut
securely.
Barrel Nut
Blower plate
Outside, top of hood
Duct tape
7" Round duct