www.charltonandjenrick.co.uk
13
LT5674 (ISS 5)
SECTION SIX Appliance Data (installation instructions)
Wall Cut-out dimensions:
Height
553mm
Width
445mm
Overall dimensions:
Height
601mm
Width
501mm
Forward Projection:90mm, (From fireplace opening Including typical fret.)
Weight:
38.5kg (Boxed excluding fret)
37kg (Unboxed excluding fret)
Flue Length and duct length:
100mm (minimum) to l metre (maximum)
Standard length supplied with fire-……………………400mm (200mm after cutting).
Additional 400mm & 1m tubes supplied as optional extras. (No bends should be fitted in the flue pipe)
Pressure Test Point Location:
Gas inlet elbow
Gas Connection:
8.0mm O/D, tube.
Data Badge Location:
On the base of appliance behind decorative fret.
NOTE: The efficiency of this appliance has been measured as specified in BS EN613-2001 and the result is 75.93%
natural gas The gross calorific value of the fuel has been used for this efficiency calculation. GasTec have certified the
test data from which it has been calculated. The efficiency value may be used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of dwellings.
MODEL
Natural Gas(G20) Version
Category of appliance
CII
NO
X
Class
3
Efficiency Class
1
Gas Category
I2H
Gas Type
G20 Natural Gas
Gas Pr/- 1.0mbar
20 mbar
Gas Input (Max)
5.2 kW Gross
(Min)
2.4 kW Gross
Injectors size
360