SECTION EIGHT Siting the Appliance (installation instructions)
(When installing in a timber framed dwelling reference must be made to the specific installation requirements stated
in Section 10 Installing the Appliance in Timber Framed Dwelling).
THERE ARE TWO TYPES OF INSTALLATION (into conventional masonry walls): -
The appliance body can be recessed back into the brickwork cavity so that the appliance is flush fitting with
the wall or fireplace back panel, see Installation Instructions,
OR
With a dummy chimneybreast constructed forward into the room to take up the 180mm depth of the firebox.
This depth can be reduced if a deep rebated surround is also used the rebate depth can be deducted from the
dummy breast depth Any surround used must meet the specification stated later in this section. Prior to
installing the appliance all combustible materials must be removed from the rear faces as described in Section
10.
*Please note - Appropriate measures should be taken when installing into a working flue system i.e. out through
an existing chimney *
GENERAL REQUIREMENTS
The flue and air duct length
must be between 100mm to
1metre. The fire is supplied with
a standard pipe length of
400mm (to be cut in half to
make a flue and air duct length
of 200mm) The flue and air duct
must not accommodate any
bends. Other lengths of flue and
air duct are available
The flue outlet must terminate
on a suitable outside wall.
The minimum flue terminal
clearances, which must be
maintained, are as shown
below.
A.
Directly below an openable window or other opening. E.g. air brick
300mm
B.
Below gutters, soil pipes or drain pipes
300mm
C.
Below eaves
300mm
D.
Below balconies or car port roofs
600mm
E.
From vertical drain pipes and soil pipes
75mm
F.
From internal and external corners
300mm
G.
Above ground, roof or balcony level
370mm
H.
From a surface facing the terminal
600mm
I.
From a terminal facing the terminal
1200mm
J.
From an opening in a car port into a dwelling e.g. door, window, etc
1200mm
K.
Vertically from a terminal on the same wall
1500mm
L.
Horizontally from a terminal on the same wall
300mm
Note: These dimensions are taken from the center of the circular flue outlet.