REMOVABLE COVER 

Effective Ventilation 
1365mm

2

 MINIMUM

 

PARAGON FOCUS RS 

Users Instructions 

 

SECTION ONE 

Important Information Cont. 

 

 

As the PARAGON FOCUS RS is a room sealed appliance (i.e. air for the combustion process is 
taken from outside the room) no purpose built ventilation is requires. 

 

The  PARAGON  FOCUS  RS  is  designed  and  tested  to  meet  the  requirements  of  the  European 
Standard EN 613. 

 

Although the PARAGON FOCUS RS is fitted with a glass front which acts as a dress guard it is 
strongly recommended that a fireguard should be used for the protection of children, the elderly or 
infirm.  Fireguards  should  conform  to  B.  S.  6539  (1984)  (Fireguards  for  use  with  solid  fuel 
appliance).

 

 

The slot located at the top of the PARAGON FOCUS RS are the hot air outlets and as such must 
not be obstructed in any way (particularly by clothes or other combustibles). In addition the base 
of  the  appliance  should  not  be  obstructed  by  such  items  as  this  may  adversely  affect  the 
performance of the appliance.

 

 

Care  should  be  taken  to  prevent  any  damage  being  caused  to  surrounding  soft  furnishings  or 
decoration. Many wall coverings may become discoloured if placed too close to the appliance, it is 
strongly  recommended that  any proposed wall covering intended for use immediately above the 
appliance should be tested in the hottest position (immediately above) first. Run the fire on high 
over a few days

 

 

The  first  time  you  light  your  new  appliance  a  smell  may  occur  due  to  its  new  condition.  This  is 
quite normal and will soon disappear after a few hours use at maximum setting (open a window 
until the smell disappears).

 

 

The  appliance 

MUST  NOT

  be  used  if  the  glass  panel  is  not  correctly  fitted  or  if  this  panel  is 

cracked or broken. 

 

 

Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all 
the loose coals have been removed.

 

 

 

Prior  to  removing  or  cleaning  the  fuel  bed  components  refer  to  the  ‘Health  and  Safety 

Notice’ located on page 3 of this booklet

 

 

The  appliance  should  be  serviced  annually  by  a  competent  person  i.e.  a 

CORGI  registered 

engineer

 in accordance with these instructions.

 

 

The  glass  or  any  part  of  the  appliance 

MUST  NOT

  be  cleaned  or  wiped  whilst  the  appliance  is 

HOT

, to do so could be dangerous and may damage the paintwork of the appliance.

 

 

The cast fire front or Fascia casing MUST BE positioned in front of the fire whilst it is burning. 

 

A where a fire front (fret) is used with this appliance it must conform to the following: 

 

It must be made from non-combustible material. 

 

Its general construction should enable it to stand firmly across the full width of the burner. 

 

The  design  of  the fire  front  (fret) 
must  have  a  removable  ashtray 
cover (lower section). 

 

The ash tray cover must have cut 
outs and or holes which provide 
ventilation to the underside of the 
burner. 

 

The  effective  area  of  ventilation 
through  the  ash  tray  cover  must 
be  greater  than  1365mm

2

  (2.12 

sq. ins.) 

 
 

Содержание Focus RS

Страница 1: ...INSET LIVE FUEL EFFECT GAS FIRE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in...

Страница 2: ...SECTION NINE Preparing the Appliance for Installation 15 SECTION TEN Install the appliance 16 Installing the Appliance into a Cavity Wall 16 Installing the Appliance into a Deep Rebated Surround or Du...

Страница 3: ...s are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste The PARAGON FOCUS RS is an inset room sealed decorative fuel effect gas applia...

Страница 4: ...first Run the fire on high over a few days The first time you light your new appliance a smell may occur due to its new condition This is quite normal and will soon disappear after a few hours use at...

Страница 5: ...THREE Operation Do not use this appliance without the glass panel fitted or if this panel is cracked or broken WARNING If the burner or pilot is extinguished for any reason do not attempt to re light...

Страница 6: ...Supermarkets Remove the glass panel as follows Remove ash pan cover and fret Remove decorative trim held in place with four magnets Slacken but do not remove the 4 nuts securing the bottom glass clam...

Страница 7: ...BED PARTS SHOULD BE ADDED to the appliance If any Fuel Bed Parts are broken then they must be replaced before the appliance is used Note There are three possible fuel bed arrangements COAL PEBBLE or...

Страница 8: ...as shown in the picture Position two A coals and three B coals as shown in the picture Finally position one A coal and two B coals as shown in the picture That completes the coal bed assembly Go to se...

Страница 9: ...their underside 2B 4off 3B 1off 4B 2off 2G 2off 4G 3off The Rear Matrix is located so that it fits behind the burned ensure it is not placed over the burner The Front Matrix is located as shown in fro...

Страница 10: ...anel and other associated parts are fitted before lighting the appliance The Driftwood set as shown consists of Rear Matrix Front Matrix Nine Individual Driftwood parts Marked on their underside D1 1o...

Страница 11: ...d shapes shown with the marking placed below or to the rear of the shape That completes the pebbles bed assembly Go to section eleven to complete the appliance assembly Ensure the glass panel and othe...

Страница 12: ...u may experience outing from cold In this case it may be necessary to remove the restrictor plate Please ensure that the flue pipe has been adequately sealed before undertaking removal of this plate M...

Страница 13: ...ISH STANDARDS B S 5871 PART 2 B S 5440 PART 1 B S 6891 B S 1945 Note This appliance must be installed to current versions of the above standards and include any relevant amendments THE BUILDING REGULA...

Страница 14: ...scribed in Section 10 GENERAL REQUIREMENTS The flue and air duct length must be between 100mm to 1metre The fire is supplied with a standard pipe length of 400mm to be cut in half to make a flue and a...

Страница 15: ...00 mm provided fire is central to the surround and sides do not project more than 150 mm When vertical side forward projection is increased by 12 5 mm add 50 mm to inside width of surround Check with...

Страница 16: ...zontal line at a height of 555mm above the hearth line joining the two outside lines together Mark the position for a lintel above the top horizontal line Mark two short horizontal lines so they cross...

Страница 17: ...t it seals to both the flue pipe and the air duct use flue seal or fire cement to ensure air tight seal Drill through the four holes in the outer wall terminal plate and fix back to the wall using plu...

Страница 18: ...ing account of the relative gas regulations appertaining to a gas pipe in a cavity Permanently fix the deep rebated surround in position and pack the void behind the fascia panel of the deep rebated s...

Страница 19: ...diameter must be fitted to these clearance holes To ensure that any condensation formed on the duct pipes does not drip on to the inner wall a length of galvanised wire must wrapped around each flue p...

Страница 20: ...e point at which the sleeved installation pipe enters the fire The Gas Safety Installation and Use Regulations Certificate of exemption number 1 of 1996 Where the pipe enters the fire the outer sleeve...

Страница 21: ...able fire fret up to the appliance conforming to the requirements referred to in section one of this manual SECTION THIRTEEN Instruct and Advise the Customer Demonstrate the lighting and extinguishing...

Страница 22: ...he left hand side 4 Disconnect the injector pipe from the left hand side of the gas control 5 Disconnect the pilot pipe from the underside of the pilot burner 9 Pull off the connection to the spark el...

Страница 23: ...s and re commission Replacement of the Pilot Injector 1 Undo the pilot tube nut at the pilot bracket 2 Pull the pipe gently back taking care not to damage 3 Remove the pilot injector from inside the p...

Страница 24: ...ust be installed by a CORGI registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a CORGI registered person 4 The servic...

Страница 25: ..._______________ ___________________________________________ Date of Purchase Service Log The following information must be complete and supported by receipts as part of the conditions of the extended...

Страница 26: ...LT4548 10 09 10 26...

Страница 27: ...AILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model PARAGON FOCUS RS Serial No Date of Purchase This information can be fou...

Страница 28: ...ssembly Air Test Completed Microswitch Check Warning Label Fire Guard Front Matrix 4607 Rear Matrix 4604 Pebble Set 4611 Installation Seal 2090 Restrictor Elbow 2189 Magnets 4 x 3048 Glass Panel Canop...

Отзывы: