Paragon Fires Focus RS Скачать руководство пользователя страница 3

LT4548 (10:09/10) 

3

 

PARAGON FOCUS RS 

 Users Instructions

 

 

SECTION ONE 

Important Information 

 

Consumer Protection Information 

As  manufacturers  and  suppliers  of  heating  products,  we  take  every  care,  as  far  as  is  reasonably 
practicable,  that  these  products  are  so  designed  and  constructed  as  to  meet  the  general  safety 
requirement  when  properly  used  and  installed.  To  this  end,  our  products  are  thoroughly  tested  and 
examined before despatch. 
 

IMPORTANT  NOTICE:

  Any  alteration  that  is  not  approved  by  the  appliance  manufacturer  could 

invalidate  the  approval  of  the  appliance,  operation  of  the  warranty  and  could  affect  your  statutory 
rights.

 

 

Health and Safety Notice 

Important 

This  appliance  could  contain  some  of  the  materials,  indicated  below,  that  could  be  interpreted  as 
being  injurious  to  health  and  safety.  It  is  the  users  /  installers  responsibility  to  ensure  that  the 
necessary  personal  protective  clothing  is  worn  when  handling  these  materials,  see  below  for 
information. 

Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn - 

may 

be harmful if inhaled, may be irritating to skin, eyes, nose and throat.  

When handling

 

avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks 

and  eye  protection.  After  handling  wash  hands  and  other  exposed  parts.  If  a  vacuum  is  used  for 
cleaning  the  coals  or  cleaning  after  servicing  /  installation  it  is  recommended  that  it  be  of  the  type 
fitted with a HEPA filter. 

Disposal  of  refractory/ceramic  materials

To  keep  dust  to  a  minimum  these  materials 

should be securely wrapped in polythene and be clearly labelled ‘RCF waste’. These materials are 
not classified as ‘hazardous waste’ and should be disposed of at a site licensed for the disposal of 
industrial waste.

 

 

The PARAGON FOCUS RS is an inset room sealed decorative fuel-effect gas appliance. 

 

The PARAGON FOCUS RS is available in 

Natural Gas (G20 @ 20 mbar) or LPG ( G31 @ 37 

mbar Only).

 The marking (

G20

 for natural gas) or (G31 for Propane Gas Only) 

on the packaging 

and  the  data  badge  specify  the  gas  for  which  the  appliance  has  been  factory  set. 

Note:  These 

appliances should only be used on the appropriate gas specified. They are not suitable for 
conversion from one gas to the other.

 

 

The PARAGON FOCUS RS 

must not

 be installed into a natural draught flue or chimney. 

 

Failure to install appliance correctly could lead to prosecution. 
In  GB  (Great  Britain),  the  appliance  must  be  installed  and  serviced  by  a  competent  person  i.e. 
CORGI-registered,  in  accordance  with  the  GAS  SAFETY  (INSTALLATION  AND  USE) 
REGULATIONS,  The  Building  Regulations  (or  The  Building  Regulations  (Scotland)  or  The 
Building Regulations (Northern Ireland)) and The Current I.E.E. Wiring Regulations, if appropriate.  
In IE (Ireland), the appliance must be installed and serviced by a competent person and installed 
in  accordance  with  the  current  edition  of  I.S.813  Domestic  Gas  Installation,  the  current  Building 
Regulations and the current ETCI rules for electrical installation, if appropriate.   

  The PARAGON FOCUS RS does not require a chimney, but 

must be

 installed against an outside 

wall. 

 

It is important that the flue terminal is regularly checked and kept clear at all times. 

 

If  the  terminal  is  accessible  to  people  (i.e.  less  than  2m  above  a  walkway,  balcony  etc.)  the 
terminal guard must be fitted to prevent access to the flue outlet, which becomes hot when the fire 
is in use.

 

 

All combustible material must be removed from behind the fire and fire trim. 

Содержание Focus RS

Страница 1: ...INSET LIVE FUEL EFFECT GAS FIRE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in...

Страница 2: ...SECTION NINE Preparing the Appliance for Installation 15 SECTION TEN Install the appliance 16 Installing the Appliance into a Cavity Wall 16 Installing the Appliance into a Deep Rebated Surround or Du...

Страница 3: ...s are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste The PARAGON FOCUS RS is an inset room sealed decorative fuel effect gas applia...

Страница 4: ...first Run the fire on high over a few days The first time you light your new appliance a smell may occur due to its new condition This is quite normal and will soon disappear after a few hours use at...

Страница 5: ...THREE Operation Do not use this appliance without the glass panel fitted or if this panel is cracked or broken WARNING If the burner or pilot is extinguished for any reason do not attempt to re light...

Страница 6: ...Supermarkets Remove the glass panel as follows Remove ash pan cover and fret Remove decorative trim held in place with four magnets Slacken but do not remove the 4 nuts securing the bottom glass clam...

Страница 7: ...BED PARTS SHOULD BE ADDED to the appliance If any Fuel Bed Parts are broken then they must be replaced before the appliance is used Note There are three possible fuel bed arrangements COAL PEBBLE or...

Страница 8: ...as shown in the picture Position two A coals and three B coals as shown in the picture Finally position one A coal and two B coals as shown in the picture That completes the coal bed assembly Go to se...

Страница 9: ...their underside 2B 4off 3B 1off 4B 2off 2G 2off 4G 3off The Rear Matrix is located so that it fits behind the burned ensure it is not placed over the burner The Front Matrix is located as shown in fro...

Страница 10: ...anel and other associated parts are fitted before lighting the appliance The Driftwood set as shown consists of Rear Matrix Front Matrix Nine Individual Driftwood parts Marked on their underside D1 1o...

Страница 11: ...d shapes shown with the marking placed below or to the rear of the shape That completes the pebbles bed assembly Go to section eleven to complete the appliance assembly Ensure the glass panel and othe...

Страница 12: ...u may experience outing from cold In this case it may be necessary to remove the restrictor plate Please ensure that the flue pipe has been adequately sealed before undertaking removal of this plate M...

Страница 13: ...ISH STANDARDS B S 5871 PART 2 B S 5440 PART 1 B S 6891 B S 1945 Note This appliance must be installed to current versions of the above standards and include any relevant amendments THE BUILDING REGULA...

Страница 14: ...scribed in Section 10 GENERAL REQUIREMENTS The flue and air duct length must be between 100mm to 1metre The fire is supplied with a standard pipe length of 400mm to be cut in half to make a flue and a...

Страница 15: ...00 mm provided fire is central to the surround and sides do not project more than 150 mm When vertical side forward projection is increased by 12 5 mm add 50 mm to inside width of surround Check with...

Страница 16: ...zontal line at a height of 555mm above the hearth line joining the two outside lines together Mark the position for a lintel above the top horizontal line Mark two short horizontal lines so they cross...

Страница 17: ...t it seals to both the flue pipe and the air duct use flue seal or fire cement to ensure air tight seal Drill through the four holes in the outer wall terminal plate and fix back to the wall using plu...

Страница 18: ...ing account of the relative gas regulations appertaining to a gas pipe in a cavity Permanently fix the deep rebated surround in position and pack the void behind the fascia panel of the deep rebated s...

Страница 19: ...diameter must be fitted to these clearance holes To ensure that any condensation formed on the duct pipes does not drip on to the inner wall a length of galvanised wire must wrapped around each flue p...

Страница 20: ...e point at which the sleeved installation pipe enters the fire The Gas Safety Installation and Use Regulations Certificate of exemption number 1 of 1996 Where the pipe enters the fire the outer sleeve...

Страница 21: ...able fire fret up to the appliance conforming to the requirements referred to in section one of this manual SECTION THIRTEEN Instruct and Advise the Customer Demonstrate the lighting and extinguishing...

Страница 22: ...he left hand side 4 Disconnect the injector pipe from the left hand side of the gas control 5 Disconnect the pilot pipe from the underside of the pilot burner 9 Pull off the connection to the spark el...

Страница 23: ...s and re commission Replacement of the Pilot Injector 1 Undo the pilot tube nut at the pilot bracket 2 Pull the pipe gently back taking care not to damage 3 Remove the pilot injector from inside the p...

Страница 24: ...ust be installed by a CORGI registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a CORGI registered person 4 The servic...

Страница 25: ..._______________ ___________________________________________ Date of Purchase Service Log The following information must be complete and supported by receipts as part of the conditions of the extended...

Страница 26: ...LT4548 10 09 10 26...

Страница 27: ...AILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model PARAGON FOCUS RS Serial No Date of Purchase This information can be fou...

Страница 28: ...ssembly Air Test Completed Microswitch Check Warning Label Fire Guard Front Matrix 4607 Rear Matrix 4604 Pebble Set 4611 Installation Seal 2090 Restrictor Elbow 2189 Magnets 4 x 3048 Glass Panel Canop...

Отзывы: