background image

MIM4-A2-GZ42-00

June 2005

7

LED Indicators

Regulatory Notices

UNITED STATES – EMI NOTICE:

!

This equipment has been tested and found to comply with the limits for a 
Class A digital device, pursuant to Part 15 of the FCC rules. These limits 
are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the 
requirements that no modifications will be made to the equipment 
unless the changes or modifications are expressly approved by 
Paradyne Corporation.

Table 1. LEDs

LED

STATE

INDICATION

ADDITIONAL 
INFORMATION

Lnk/Alm

(Port 1 – Port 4)

Flashing Green*

Connection is established 
and active.

Traffic is flowing.

Solid Green

Problematic connection.

A connection exists but no data 
is being passed.

No Illumination

Red Alarm. The incoming 
connection to the MIM has 
been lost; no data is being 
received.

If the outgoing connection from 
the MIM has also been lost 
then the remote E1 equipment 
to which the MIM is connected 
will be in Red Alarm as well.

Solid Amber

Yellow Alarm. The outgoing 
connection from the MIM 
has been lost; no data is 
being transmitted.

The remote E1 equipment has 
lost its incoming connection 
and is in Red Alarm.

Pulsing Amber

Blue Alarm. An indirect 
connection has been lost; 
the MIM may no longer be 
receiving data from the 
remote E1 equipment.

The remote E1 equipment has 
lost a connection with an 
intermediate device and is in 
Red or Yellow Alarm.

Act

(Port 1 – Port 4)

Flashing Green

Transmitting data.

Flashing Amber

Receiving data.

*

A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, 
less constant rate.

!

Содержание MIM-4E1

Страница 1: ...cluding any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporation...

Страница 2: ...UT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limitat...

Страница 3: ...rts for the 4929 DSLAM or BSX8000 5 Broadband Services Switch NOTE All MIMs are hot swappable although removal of a MIM disengages the upstream network connection for the DSLAM Procedure 1 Using a fla...

Страница 4: ...er to the E1 Loop Bonding Product to Product Feature Compatibility list Document Number COMP A2 GK43 Procedure 1 If ferrite chokes are supplied with your MIM Open a ferrite choke One or two cables wil...

Страница 5: ...g a shielded E1 cable for your network connection it must be grounded through pins 3 6 7 and 8 E1 Default Settings No configuration is necessary for the MIM 4E1 to operate at default settings Speed Ad...

Страница 6: ...option to disable the Cyclic Redundancy Check function Line Code Line code is the E1 mode of transmission The two line code options outlined below both fall within the International Telecommunication...

Страница 7: ...ved by Paradyne Corporation Table 1 LEDs LED STATE INDICATION ADDITIONAL INFORMATION Lnk Alm Port 1 Port 4 Flashing Green Connection is established and active Traffic is flowing Solid Green Problemati...

Страница 8: ...istributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locat...