MIM4-A2-GZ42-00

June 2005

5

Procedure

1. If a ferrite choke is supplied with your MIM:

— Open the ferrite choke.

— Make a loop at the end of your cable and close it in the ferrite choke. 

Position the choke as close as possible to the RJ48C connector.

— Snap shut the ferrite choke.

2. Plug your E1 cable into one of the E1 RJ48C ports on the MIM-4E1. Any port 

may be used. 

3. Verify the connection: the E1 link LED on the front of the MIM will flash green 

to indicate the connection is established and operational.

E1 RJ48C Pinouts

If you are using a shielded E1 cable for your network connection, it must be 
grounded through pins 3, 6, 7, and 8.
  

E1 Default Settings

No configuration is necessary for the MIM-4E1 to operate at default settings:

„

Speed: Adaptive. The MIM-4E1 determines timeslot and bandwidth 
configurations via communication with the remote E1 equipment to which it is 
connected. Each E1 connection has the capability of receiving data across all 
31 channels at 1,984 kbps.

„

Frame Type: Cyclic Redundancy Check (CRC)

„

Line Code: High Density Binary 3 (HDB3)

„

Timing: Adaptive. The MIM-4E1 determines clock source via communication 
with the remote E1 equipment to which it is connected.

PIN

CONNECTION

1

Rx  Ring

2

Rx Tip

3

not used

4

Tx Ring

5

Tx Tip

6

not used

7

not used

8

not used

Содержание MIM-4E1

Страница 1: ...cluding any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporation...

Страница 2: ...UT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limitat...

Страница 3: ...rts for the 4929 DSLAM or BSX8000 5 Broadband Services Switch NOTE All MIMs are hot swappable although removal of a MIM disengages the upstream network connection for the DSLAM Procedure 1 Using a fla...

Страница 4: ...er to the E1 Loop Bonding Product to Product Feature Compatibility list Document Number COMP A2 GK43 Procedure 1 If ferrite chokes are supplied with your MIM Open a ferrite choke One or two cables wil...

Страница 5: ...g a shielded E1 cable for your network connection it must be grounded through pins 3 6 7 and 8 E1 Default Settings No configuration is necessary for the MIM 4E1 to operate at default settings Speed Ad...

Страница 6: ...option to disable the Cyclic Redundancy Check function Line Code Line code is the E1 mode of transmission The two line code options outlined below both fall within the International Telecommunication...

Страница 7: ...ved by Paradyne Corporation Table 1 LEDs LED STATE INDICATION ADDITIONAL INFORMATION Lnk Alm Port 1 Port 4 Flashing Green Connection is established and active Traffic is flowing Solid Green Problemati...

Страница 8: ...istributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locat...

Отзывы: