3. Initial Startup and Configuration
8776-A2-GB20-40
February 2001
3-11
Table 3-1, Fixed Rate Payload Rates and DSL Line Rates
, provides the maximum
payload rates achievable for each DSL line rate and the number of time slots
required to achieve that payload rate depending on whether you are using
signaling (time slots 0 and 16) or data only (time slot 0).
Resetting AutoRate
The Reset AutoRate function on the Control menu causes the unit to repeat the
AutoRate sequence. The unit attempts to establish the DSL link at the highest rate
(or the value of DSL Line Rate, which represents the AutoRate ceiling when
AutoRate is enabled). If the link fails, the next lower rate is tried until the link is
established.
To access the Reset AutoRate screen, follow this menu selection sequence:
Main Menu
→
Control
→
Reset AutoRate
Table 3-1.
Fixed Rate Payload Rates and DSL Line Rates
Voice Mode
(G.703-to-G.703)
Data Mode
(G.703-to-G.703)
Data Mode
(G.703-to-EIA-530-A)
DSL Line
Rate (kbps)
Maximum
Payload
Rate (kbps)
Time
Slots
Maximum
Payload
Rate (kbps)
Time
Slots
Maximum
Payload
Rate (kbps)
Time
Slots
2064
1920 30
1984
31
1984
31
1552
1408 22
1472
23
1536
24
1040
896
14
960
15
1024
16
784
640
10
704
11
768
12
528
384
6
448
7
512
8
400
256
4
320
5
384
6
Содержание Hotwire 8776
Страница 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8776 A2 GB20 40...
Страница 52: ...4 Monitoring the Unit 4 16 February 2001 8776 A2 GB20 40...
Страница 62: ...5 Testing 5 10 February 2001 8776 A2 GB20 40...
Страница 68: ...6 Messages and Troubleshooting 6 6 February 2001 8776 A2 GB20 40...
Страница 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8776 A2 GB20 40...
Страница 102: ...D Technical Specifications D 2 February 2001 8776 A2 GB20 40...
Страница 112: ...Index IN 6 February 2001 8776 A2 GB20 40...