5. Testing
5-6
February 2001
8776-A2-GB20-40
Remote Send Line Loopback
The local unit initiates this test by sending a line loopback Up or Down command
to the remote unit for 10 seconds. When the remote unit detects the loopback Up
command, it puts itself in line loopback and lights the front panel Test LED. The
remote unit remains in loopback until it receives a loopback Down command or the
remote unit's test timeout value is exceeded.
The Send Line Loopback tests both units. External equipment can be used to
verify the link.
Procedure
To run a Remote Send Line Loopback:
1. Position the cursor at the Up or Down selection next to Send Line Loopback on
the Network & G.703 Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to Up or Down selection.
4. Press Enter.
The local unit stops sending the loopback command automatically after
10 seconds. You cannot stop the Remote Send Line Loopback test manually.
The Remote Send Line Loopback cannot be started when any other loopback or a
Send and Monitor 511 test is active on the network interface.
CAP
G.703
Port
CAP
E1
LIU
Framer
Framer
Transceiver
98-16001
CAP
CAP
E1
LIU
Framer
Framer
Transceiver
AIS
Local
Remote
Содержание Hotwire 8776
Страница 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8776 A2 GB20 40...
Страница 52: ...4 Monitoring the Unit 4 16 February 2001 8776 A2 GB20 40...
Страница 62: ...5 Testing 5 10 February 2001 8776 A2 GB20 40...
Страница 68: ...6 Messages and Troubleshooting 6 6 February 2001 8776 A2 GB20 40...
Страница 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8776 A2 GB20 40...
Страница 102: ...D Technical Specifications D 2 February 2001 8776 A2 GB20 40...
Страница 112: ...Index IN 6 February 2001 8776 A2 GB20 40...