1. Network Management Specification
8000-A2-GB30-30
June 2004
79
8.1.2.1.9
entPhysicalSoftwareRev:
The vendor-specific software revision string for the physical entity. If no specific firmware
programs are associated with the physical component, or this information is unknown to the
agent, then this object will contain a zero-length string. For the BAC units, this object will
always return a zero-length string.
8.1.2.1.10
entPhysicalFirmwareRev
The vendor-specific software revision string for the physical entity.
Valid Object Value(s):
The following table shows the entPhysicalFirmwareRev assigned for the entities.
Splitter card
String containing the Revision Number of the CCA
DSL Port
zero-length-string
T1/E1 port
zero-length-string
OC3 port
zero-length-string
DS3 port
zero-length-string
GigE/100BT port
zero-length-string
Console port
zero-length-string
Ethernet Mgmt port
zero-length-string
Temp Sensor
zero-length-string
Fan
zero-length-string
PowerSupply
zero-length-string
Management Plane PLD
zero-length-string
Uplink PLD
zero-length-string
Table 1-92. entPhysicalFirmwareRev (1 of 2)
Entity
entPhysicalFirmwareRev
Chassis
zero-length-string
Container
zero-length-string
Module
A String with the currently Firmware running in this module.
Uplink Module
A String with the currently Firmware running in this module.
Splitter card
zero-length-string
DSL Port
A String reflecting the DSP revisions
T1/E1 port
zero-length-string
OC3 port
zero-length-string
DS3 port
zero-length-string
Table 1-91. entPhysicalHardwareRev (2 of 2)
Entity
entPhysicalHardwareRev