![Paradyne Hotwire 7975 Скачать руководство пользователя страница 99](http://html2.mh-extra.com/html/paradyne/hotwire-7975/hotwire-7975_user-manual_3639330099.webp)
B-1
7975-A2-GB20-40
December 1998
Standards Compliance for
SNMP Traps
B
SNMP Traps
This section describes the unit’s compliance with SNMP standards and any
special operational features for the SNMP traps supported. The unit supports the
following traps:
H
warmStart
H
authenticationFailure
H
linkUp
H
linkDown
warmStart
SNMP Trap
Description
Possible Cause
warmStart
The unit has reinitialized
itself.
The trap is sent after the
unit resets and stabilizes.
There are no
variable-bindings.
H
Reset command.
H
Power disruption.
authenticationFailure
SNMP Trap
Description
Possible Cause
authenticationFailure
Failed attempts to access
the unit.
There are no
variable-bindings.
Three unsuccessful attempts
were made to enter a correct
login/password combination.