Testing
6-4
7970-A2-GB20-00
August 1999
Remote Network Send Line Loopback
The local unit initiates this test by sending a line loopback Up or Down command
to the remote unit for 10 seconds. When the remote unit detects the loopback Up
command, it puts itself in line loopback and lights the front panel test LED. The
remote unit remains in loopback until it receives a loopback Down command or
the remote unit’s test timeout value is exceeded. The send line loopback tests
both units. External equipment can be used to verify the link.
CAP
DSX-1
Port
CAP
T1
LIU
Framer
Framer
Transceiver
98-16109
CAP
CAP
T1
LIU
Framer
Framer
Transceiver
AIS
Local
Remote
"
Procedure
To run a Remote Network Send Line Loopback:
1. Position the cursor at the Up or Down selection next to Send Line Loopback
on the Network & DSX-1, Network, or Network & G.703 Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to Up or Down selection.
4. Press Enter.
The local unit stops sending the loopback command automatically after
10 seconds. You cannot stop the Send Line Loopback test manually.
The Remote Network Send Line Loopback cannot be started when any other
loopback or a Send and Monitor 511 test is active on the network interface.
Содержание Hotwire 7974
Страница 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 44: ...Initial Startup and Configuration 3 16 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999...