Monitoring the Unit
5-8
7970-A2-GB20-00
August 1999
Network Error Statistics are collected for:
H
ES (Errored Seconds): Seconds during which one or more CRC error
events occurred.
H
SES (Severely Errored Seconds): Seconds during which more than
320 cyclic redundancy check (CRC) error events or at least one Out of Frame
(OOF) event occurred.
H
FEBE (Far-End Block Errors): Errors reported by the remote equipment.
H
Complete: Whether the interval register contains data for a complete
900-second interval.
Use the virtual function keys to page through the intervals and clear statistics.
This Field . . .
Contains . . .
Current Interval
Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Error Events
Counter
A running total of CRC errors. Range 0–65535. This counter
resets when the near-end data is cleared.
Current Int
Performance data for the current 15-minute interval.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of
xx is from 01 to 96.
Worst Interval
The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.
Near and Far Tot
A 24-hour running total of the near- and far-end performance
statistics.
Содержание Hotwire 7974
Страница 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 44: ...Initial Startup and Configuration 3 16 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999...