Configuration Option Tables
A-27
7970-A2-GB20-00
August 1999
Table A-11.
SNMP Traps Options (1 of 2)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Controls the generation of SNMP trap messages.
Enable – SNMP trap messages are sent out to SNMP managers.
Disable – No SNMP trap messages are sent out.
Number of Trap Managers
Possible Settings: 1, 2, 3, 4, 5
Default Setting: 1
Sets the number of SNMP management systems that will receive SNMP traps.
H
This field does not appear if the unit is connected to a DSLAM card running in IP
Conservative mode.
1 to 5 – Number of trap managers. An NMS IP address is required for each manager.
NMS
n IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the Internet Protocol address used to identify each SNMP trap manager.
H
This field does not appear if the unit is connected to a DSLAM card running in IP
Conservative mode.
Address Field – (001.000.000.000 – 223.255.255.255) – Enter an address for each
SNMP trap manager. The range for the first byte is 001 to 223, with the exception of
127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the IP address and sets to all zeros.
NMS
n Destination
Possible Settings: DSL, COM
Default Setting: DSL
Provides the network destination path of each trap manager.
H
This field does not appear if the unit is connected to a DSLAM card running in IP
Conservative mode.
DSL – The DSL port is the network destination path.
COM – The COM port is the network destination path.
General Traps
Possible Settings: Disable, Warm, AuthFail, Both
Default Setting: Both
Determines which SNMP traps are sent to each trap manager.
Disable – No general trap messages are sent.
Warm – Sends trap message for
warmStart events.
AuthFail – Sends trap message for
authenticationFailure events.
Both – Sends both trap messages.
NOTE:
Refer to Appendix B,
Standards Compliance for SNMP Traps
.
Содержание Hotwire 7974
Страница 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 44: ...Initial Startup and Configuration 3 16 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999...