Monitoring the Unit
5-5
7970-A2-GB20-00
August 1999
Self-Test Results Messages
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 5-2.
Self-Test Results Messages
Message
What Message Indicates
What To Do
Passed
No errors were detected.
CPU Failed
The CPU failed internal testing.
1. Reset the unit and
try again
Device Failed
One or more of the unit’s integrated circuit
chips failed device-level testing.
try again.
2. Call your service
representative for
DSX-1 Failed
Sync Port Failed
G.703 Failed
The unit failed to loop data on the DTE
interface circuit.
re resentative for
assistance.
Memory Failed
The unit failed memory verification.
FPGA Failed
A failure in the FPGA was detected.
DataPath Failed
The unit failed to loop data between the
DSX-1 Port and the DSL loop.
Failure
xxxxxxxx
An internal failure occurred.
(xxxxxxxx
represents an 8-digit hexadecimal failure
code for use by service personnel.)
Record the failure code
and contact your
service representative.
Содержание Hotwire 7974
Страница 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 44: ...Initial Startup and Configuration 3 16 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Страница 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999...