background image

COMSPHERE

3600 SERIES

DATA SERVICE UNITS

MODELS 3610 AND 3611

TIME DIVISION MULTIPLEXER,

MULTICHANNEL MULTIPOINT, AND

DIGITAL BRIDGE OPTIONS

APPLICATIONS GUIDE

Document No. 3610-A2-GB41-70

July 1999

Содержание COMSPHERE 3610

Страница 1: ...COMSPHERE 3600 SERIES DATA SERVICE UNITS MODELS 3610 AND 3611 TIME DIVISION MULTIPLEXER MULTICHANNEL MULTIPOINT AND DIGITAL BRIDGE OPTIONS APPLICATIONS GUIDE Document No 3610 A2 GB41 70 July 1999...

Страница 2: ...em to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please inc...

Страница 3: ...ervice personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of...

Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB41 70 Notices...

Страница 5: ...Warranty and Support 1 9 2 Model 3610 Installation Overview 2 1 Hardware Straps 2 2 Changing Hardware Settings 2 4 Electrical Connection 2 8 Network Diagnostic Connection 2 10 Software Configuration...

Страница 6: ...on Overview 4 2 Network Terminology 4 2 Modes Of Operation 4 4 Time Division Multiplexing 4 5 Multichannel Multipoint 4 21 Digital Bridge 4 35 NMS Control 4 52 SNA Diagnostic Interface 4 53 5 DSU Oper...

Страница 7: ...ture and Signal Flow 4 7 4 4 Single Port Point to Point Circuit with Nondisruptive Diagnostics 4 8 4 5 Multipoint Async Compatible Network 4 9 4 6 Point to Point Multiplexing 4 10 4 7 TDM with Extende...

Страница 8: ...ing in a Point to Point Circuit 4 58 4 47 Digital Sharing in a Multipoint Circuit 4 59 4 48 Digital Sharing in a TDM Circuit LPDA 2 Monitoring 4 60 4 49 Digital Sharing in an MCMP Circuit LPDA 2 Monit...

Страница 9: ...All Drops D 16 D 9 Extended Bridge Configuration Automatic Partial Backup Active Dial Backup Active for Two Drops D 17 D 10 NMS Controlled Full Backup Configuration Dial Backup Not Active D 20 D 11 NM...

Страница 10: ...figuration Options 5 36 5 10 Complete List of MUX Port Configuration Options 5 38 5 11 Poll List Menu Options 5 40 5 12 Directory Entry and Password Characters 5 42 5 13 Control Branch Menu Options 5...

Страница 11: ...nfiguration or if your application uses DBM Vs DBM Ss or DBM Ds It also provides a NetViewt commands reference for your convenience How to Use this Guide Chapter 1 gives a general overview of the feat...

Страница 12: ...r Unit Installation Guide 3610 A2 GB42 COMSPHERE 3600 Series Data Services Units Models 3610 and 3611 Secondary Channel Applications Supplement 6700 A2 GB41 COMSPHERE 6700 Series Network Management Sy...

Страница 13: ...e The time division multiplexing multichannel multipoint digital bridge and multipoint backup capabilities are discussed in this applications guide LPDA 2 interoperability as it applies to application...

Страница 14: ...ithout the TDM or MCMP option are also available with the TDM or MCMP option Control of a TDM MCMP digital bridge session can be performed from the DCP from an Async Asynchronous Terminal or from a CO...

Страница 15: ...r both the inbound toward the control DSU and outbound from the tributary DSU directions Digital bridge The TDM can be configured to perform a digital bridge function The digital bridge capability can...

Страница 16: ...annels The channel speed choices are the same as those for synchronous operation The word size can range from 6 to 10 bits and one or two stop bits can be specified Asynchronous data rates of 150 300...

Страница 17: ...e performed if the DSU s rate is not equal to the DBM s rate Security The V 32 DBM or DBM V the 4 wire Switched 56 DBM or DBM S or the 2 wire Switched 56 DBM or DBM D provide four levels of call setup...

Страница 18: ...ingle multiport interface connector mounted directly onto the rear of the TDM or MCMP circuit card The EIA 232 D V 24 or V 35 interface connector at the rear of the DSU is Port 1 the TDM or MCMP multi...

Страница 19: ...RK DIAGNOSTIC INTERFACE DBM INTERFACE DDS INTERFACE LOW VOLTAGE AC POWER IN COMSPHERE 3610 PORT 5 PORT 6 PORT 2 PORT 3 PORT 4 ADDITIONAL EIA 232 INTERFACES PORT NUMBERS 2 6 STATUS INDICATORS TABLE TOP...

Страница 20: ...COMSPHERE 3600 Series Data Service Units 1 8 July 1999 3610 A2 GB41 70 Figure 1 2 Model 3611 DSU with TDM or MCMP...

Страница 21: ...h AT T MCIr and US SPRINTr using dedicated 4 wire access DBM D A DBM D provides the capability to utilize the 2 wire switched 56 kbps digital service to back up a failed multipoint DDS circuit via a d...

Страница 22: ...COMSPHERE 3600 Series Data Service Units 1 10 July 1999 3610 A2 GB41 70...

Страница 23: ...nector Order a V 35 adapter cable feature number 3000 F1 510 for each TDM or MCMP port that you intend to operate as a V 35 interface All ports are configured for EIA 232 operation before leaving the...

Страница 24: ...ormation order the COMSPHERE 3600 Series Data Units Models 3610 and 3611 Dial Backup Module and SNA Diagnostic Interface Options Applications Guide Hardware Straps HANDLING PRECAUTIONS FOR STATIC SENS...

Страница 25: ...Model 3610 Installation 2 3 3610 A2 GB41 70 July 1999 Figure 2 1 Model 3610 TDM Flex or MCMP Flex Switch Locations Figure 2 2 Model 3610 TDM DSD or MCMP DSD Circuit Card Switch Locations...

Страница 26: ...d make sure that the unit is disconnected from its power source before changing the Flex interface switch position Procedure 1 With the unit upside down use a small flat head screwdriver to release th...

Страница 27: ...lat cable by gently working the cable not the connector free of its connector Be careful not to bend any of the cable pins 5 Disconnect the TDM MCMP flat cable 6 Unscrew the three screws that hold the...

Страница 28: ...but only Strap 1 is used S1 is not installed on 2 port versions of the TDM Flex or MCMP Flex 3 Insert a small pointed tool into position 1 of Switch S1 and carefully flip the switch in the direction o...

Страница 29: ...hat from the rear the option card reads THIS SIDE FACES REAR FOR V 35 3 Reinstall the DSU circuit card securing it to the base with the three screws refer to Figure 2 4 4 Reconnect the LCD keypad and...

Страница 30: ...to the ac outlet The unit performs a power up routine CAUTION Only use the power transformer designed for the Model 3610 DSU Using other transformers may result in personal injury or damage to the equ...

Страница 31: ...ACE PORT 1 EIA 232 D V 24 INTERFACE PORT 1 PORT 2 PORT 3 PORT 4 LOW VOLTAGE AC POWER IN DBM INTERFACE DDS INTERFACE NETWORK DIAGNOSTIC INTERFACE PORT 5 PORT 6 NOTE ADDITIONAL EIA 232 INTERFACES PORT N...

Страница 32: ...611 Operator s Guide Network Diagnostic Connection The DSU may be set up for a diagnostic interface with the NMS using a 3600 Hubbing Device For further information about installing a hubbing device o...

Страница 33: ...TDM or MCMP can be configured from an NMS provided the Position configuration option Diagnostic General is set to Trib from the DCP and the DSU is connected to a control DSU that is connected to the N...

Страница 34: ...l Backup mode to ensure that both DSUs have been configured correctly 3 Perform a Digital Test on both the DBM and the PSTN or switched 56 kbps circuit For a DSU equipped with both DBM and TDM or MCMP...

Страница 35: ...2 port TDM Flex or MCMP Flex is not supported If installing a 6 port TDM Flex or MCMP Flex and your DSU has a wall mount ac transformer a table top transformer must be ordered part number 654 0099 01...

Страница 36: ...led BACKUP and CC DC respectively if installed 4 Disconnect the EIA 232 D V 24 or V 35 interface cable from the DSU 5 If a TDM or MCMP is being replaced disconnect the additional port interface cable...

Страница 37: ...clean ESD anti static workpad 5 Write the serial number from the existing base onto the new TDM or MCMP expanded base using indelible ink see Figure 2 3 Discard the existing base and rear panel Insta...

Страница 38: ...plug of the table top ac transformer into the ac outlet If installing a 6 port TDM Flex or MCMP Flex and the DSU has a wall mount ac transformer the wall mount ac transformer must be replaced with a...

Страница 39: ...point to point circuit with diagnostic protocol set to ADp When a TDM or MCMP is installed Port 1 of the DSU is configured to operate at 9 6 kbps with the TDM or MCMP capability enabled all other por...

Страница 40: ...nnector module is a 25 pin connector that provides the EIA 232 DTE interface All port connectors are individual with this type of unit and a separate crossover cable is required for each connector tha...

Страница 41: ...est Mode Indication jumper is enabled the V 35 lead NN and Pin 25 on the EIA 232 D V 24 interface go to ON EIA level condition during a Test mode This is the default setting on a DBM V DBM S or DBM D...

Страница 42: ...Multipoint and Digital Bridge Options User s Guide Supplement or Configuration Options Chapter 6 of the COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Operator s Guide For a listing of...

Страница 43: ...o verify network operation Procedure 1 Request a device Identity ID from the Status branch report from each tributary to ensure that the DSU is addressed properly 2 Perform a Digital Test on the DDS c...

Страница 44: ...iguration Options Opts submenus Adding a TDM or MCMP to an Installed Model 3611 DSU This section describes the installation procedure for adding the TDM or MCMP option onto the Model 3611 DSU and then...

Страница 45: ...ing standoff posts to the DSU with the two Phillips head screws and flat washers Tighten the screws until the standoff posts fit snugly against the circuit card do not overtighten 7 Install the black...

Страница 46: ...iguration for a tributary or FacC for a control 2 Confirm the installed hardware options DBM TDM or MCMP 3 Re execute the Device Test from the SDCP Press the key to return to the top level menu then s...

Страница 47: ...Model 3611 Installation 3 9 3610 A2 GB41 70 July 1999 Figure 3 3 Non Modular TDM or MCMP Installation...

Страница 48: ...00 Series Carrier you can remove the modular DSU with a TDM or MCMP without disconnecting the DTE cables at the rear of the carrier Each port on the connector module is a DB25 connector which provides...

Страница 49: ...ll out and down on the latch at the bottom of the modular DSU s faceplate until the circuit card starts to come out of its slot in the carrier Pull the circuit card free of the carrier and set the DSU...

Страница 50: ...ar TDM or MCMP Make sure that the double ended pin headers are properly aligned Then snap the snaplock posts into the modular TDM or MCMP 6 Use the remaining four Phillips head screws and flat washers...

Страница 51: ...U TDM or DSU MCMP unit free of the carrier and lay it on a clean ESD workpad 4 On the TDM or MCMP side of the unit remove the screws securing the standoff posts to the TDM or MCMP circuit card For a n...

Страница 52: ...COMSPHERE 3600 Series Data Service Units 3 14 July 1999 3610 A2 GB41 70...

Страница 53: ...ultichannel Multipoint 4 21 Line and Channel Speeds 4 23 MCMP Overhead Composition 4 23 Management Channel 4 23 In Band Secondary Channel Transport 4 23 Number of Tributaries 4 23 MCMP Architecture 4...

Страница 54: ...An MCMP can be configured to provide point to point time division multiplexing multichannel multipoint multiplexing or digital bridge capability Network Terminology Data transmission between 3600 Seri...

Страница 55: ...The FEP a communications computer associated with a host computer is the data terminal equipment DTE at the control DSU A 3600 Series DSU can be configured as a control or as a tributary in multipoint...

Страница 56: ...no TDM or MCMP circuit card attached to the DSU TDM Mode In TDM mode data paths are established between the DSU and TDM to increase the port capacity of the DSU to six ports All six ports can be confi...

Страница 57: ...h TDM or MCMP operating in TDM mode can provide the equivalent of up to six point to point circuits via a single DDS line Figure 4 2 This single DDS line is able to carry six separate channels by inte...

Страница 58: ...proper operation the receiving TDM must be in synchronization with the transmitting TDM To ensure synchronization the transmitting TDM adds an extra bit to each TDM frame called a framing bit to crea...

Страница 59: ...a physical EIA 232 D V 24 or V 35 interface Ports 2 through 6 comply with a subset of EIA 232 interface recommendations The circuit leads supported on Ports 1 through 6 are discussed in Appendix C NOT...

Страница 60: ...3611 Operator s Guide for the maximum diagnostic rate that can be run for various asynchronous to synchronous configurations Note that in this table None indicates that no excess bandwidth is availab...

Страница 61: ...control DSU s software version is 6 xx otherwise the units should be returned to the factory to be upgraded Contact your authorized service representative to arrange for your upgrade Figure 4 5 shows...

Страница 62: ...s Figure 4 6 shows a typical TDM application In point to point multiplexing the DTEs at Port 1 communicate with one another the DTEs at Port 2 communicate with one another and so on The TDM point to p...

Страница 63: ...tend diagnostic control to other Paradyne devices at the remote location Digital Sharing Digital sharing is a TDM or MCMP feature that allows up to six ports to share the same channel Typically this i...

Страница 64: ...COMSPHERE 3600 Series Data Service Units 4 12 July 1999 3610 A2 GB41 70 Figure 4 8 Digital Sharing...

Страница 65: ...configured as a digital sharing group For example two digital sharing groups can be multiplexed with the remaining port forming three channels as shown in Figure 4 9 The three channels are designated...

Страница 66: ...configuration option to DTE and its TxCarrSel configuration option to Cntrl Set the control DSU s port RxCarrSel configuration option to Cntrl In addition at the control DSU FEP port sharing can be co...

Страница 67: ...Principles of Operation 4 15 3610 A2 GB41 70 July 1999 Figure 4 10 FEP Port Sharing...

Страница 68: ...he DDS network is out of service the network management system can initiate dial backup or if configured for automatic dial backup the control or tributary DSU can initiate dial backup Once the link i...

Страница 69: ...ous ports must be configured for underspeed One possible configuration is to allow one port to remain at 9600 bps reconfigure one port to 4800 bps running at underspeed and reconfigure all other ports...

Страница 70: ...ed of the extended circuit must be reduced then the speed of the extended modems must be reduced accordingly The speed selection feature of the TDM circuit card will provide this function to modems su...

Страница 71: ...s or less Figure 4 14 The Switched 56 DBM provides full backup of point to point single port and TDM circuits operating at 56 kbps If the DDS circuit is operating at less than 56 kbps rate adaption is...

Страница 72: ...DBM when in Dial Backup mode The DBM S should be commanded to dial the remote DBM using the Dial command and to activate the data over the backup line using the switch to Dial Dial command The DSU sho...

Страница 73: ...tions over a single 56 kbps standard multipoint digital facility The MCMP capability provides up to six user selectable full duplex channels plus a channel for diagnostic transport Any of the user sel...

Страница 74: ...BB and Channel C is assigned to Port 3 allowing the security systems connected to this port to access application CC Figure 4 17 shows how the three independent applications can be combined via the MC...

Страница 75: ...out disrupting user transmitted data When the MCMP capability is activated for the first time the control DSU with MCMP determines the roundtrip delay parameters that are critical to MCMP operation MC...

Страница 76: ...een the MCMP and the DSU and emerges as a physical interface either EIA 232 D V 24 or V 35 on the DSU The DTE cabling for the MCMP capability is the same cabling used for the TDM capability For non mo...

Страница 77: ...r Stop Bits During MCMP operation the Channel Speed and Asynchronous configuration values at the control DSU are downloaded to the tributaries on the control DSU s poll list every 10 seconds The downl...

Страница 78: ...digital sharing at the same time Up to three digital sharing groups can be formed at each tributary site A digital sharing group is formed by assigning the same channel to each port in the group All p...

Страница 79: ...to the MUX Configuration Options section of Chapter 5 Figure 4 20 shows an MCMP application using three channels where a digital sharing group has been formed at each of the tributary locations Notic...

Страница 80: ...ed for extended bridge EBrdg mode is used to bridge the aggregate data stream to the DBMs If the control DSU MCMP is enabled for Aggregate Switching aggregate data data framing and diagnostics is rout...

Страница 81: ...t Because the backup is performed in TDM mode both TDM and MCMP configuration options must be set Therefore Port 1 at the control DSU should be mapped to Port 1 at the tributary DSU For Case 1 only tw...

Страница 82: ...ation must be equipped with a DBM and the MCMP Backup configuration option must be set to TDM with only one port assigned bandwidth At the central site an extended bridge and a DBM V for each tributar...

Страница 83: ...dge unit and DBM Vs where it is routed to the tributary DSU s via the PSTN connections All other channels to the tributaries in backup are lost until the alarm is fixed and the MCMP circuit is restore...

Страница 84: ...operating in TDM mode must be available for each tributary to be backed up Using the FEP port sharing feature three channels from the control DSU MCMP can be daisy chained to a set of DSU DBM TDM uni...

Страница 85: ...rl at the control Since the dial backup operation is performed in TDM mode the MCMP channel to port assignment capability is not available Port 1 at the control DBM should map to Port 1 at the tributa...

Страница 86: ...e or Disr To establish a partial backup command the control DBMs to call the remote DBMs using the Dial command followed by the sf command from the 6800 Series NMS or Dial command from the DCP DSU tim...

Страница 87: ...ridge EBrdg when more bridging capability is needed The digital bridge capability allows for multipoint transmission from a local digital bridge Figure 4 28 as opposed to network bridging The DTE conn...

Страница 88: ...SU MCMP units configured as an extended bridge EBrdg can be connected to the central site bridge the controlling bridge Up to four extended bridges can be added to a central site bridge to provide a t...

Страница 89: ...le for each bridge port When the digital bridge is active as shown in Figure 4 30 data from the controlling DTE flows to the aggregate data path of the TDM or MCMP circuit card where it is broadcast t...

Страница 90: ...DSU through a backup connection Full backup to each tributary on multipoint circuits is necessary when the speed of the DDS line and the dial backup modules cannot be matched or when the DDS facility...

Страница 91: ...Principles of Operation 4 39 3610 A2 GB41 70 July 1999 Figure 4 31 Multipoint DDS Circuit in Partial Backup...

Страница 92: ...y DSU Figure 4 32 The term under as used here means that the sequential address begins with the control channel followed by the slash delimiter and the DSU network address followed by the slash delimi...

Страница 93: ...Principles of Operation 4 41 3610 A2 GB41 70 July 1999 Figure 4 33 Tributary Addressing via Backup Connections...

Страница 94: ...nfiguration option Bridge Rate is set to DSU the first port of the digital bridge is included in the digital sharing group Under these conditions the digital bridge is active during normal operation a...

Страница 95: ...from the DDS line Figure 4 35 incoming data from the DDS line is merged with incoming data from tributaries communicating with the bridge via DBM V DBM S or DBM D and backup connections NOTE In multi...

Страница 96: ...ation To go into full backup the bridge may be activated by an 6800 Series NMS Standby Facility sf command or from the DCP Backup Bkup command Figures 4 36 and 4 37 illustrate this The 6700 Series NMS...

Страница 97: ...s and Call Setup security procedures as DBMs at the tributary location The DBM V DBM S or DBM S is addressed just as a DBM is addressed via an NMS or the SDCP Likewise configuration options are set ju...

Страница 98: ...cting DBMs are not required to have the V 13 feature enabled Tributary DSU Considerations In multipoint backup the firmware version of the tributary DSU DBM in a multipoint circuit determines the feat...

Страница 99: ...V pair should have compatible security options If there is a failure in the backbone DDS network the control DSU reports a Facility Alarm FA or Tributary Time out Alarm Time to the NMS The 6700 Series...

Страница 100: ...the DSD capability at a remote location The 3600 Series DSUs with the digital bridge capability TDM or MCMP circuit card operating in Bridge mode can be used to support multipoint LADS operation Table...

Страница 101: ...eater than 19 2 kbps the distance between the DSUs and the digital bridge should not exceed one digital bridge interface cable Digital bridge interface cabling between the digital bridge ports and the...

Страница 102: ...COMSPHERE 3600 Series Data Service Units 4 50 July 1999 3610 A2 GB41 70 Figure 4 38 Bridged LADS Operation...

Страница 103: ...4 39 the Bridge Rate configuration option must be set to DSU Configuration options are set via the DCP as discussed in Chapter 5 the Bridge Rate configuration option is discussed in the MUX Configurat...

Страница 104: ...with TDM or MCMP the DATAPHONE II System Controller cannot configure the TDM ports or set port speeds Only the COMSPHERE 6700 or 6800 Series NMS can fully support TDM digital bridge and MCMP capabili...

Страница 105: ...twork configuration options as well as access sophisticated alarm tracking reports The carrier mounted Model 3611 DSU or the standalone Model 3610 DSU can receive the SNA Diagnostic Interface firmware...

Страница 106: ...terface option passes LPDA 2 commands via Port 1 of the TDM or MCMP NOTE For MCMP the channel assigned to Port 1 at the control DSU control tributary must also be assigned to Port 1 at each tributary...

Страница 107: ...wed to respond to the LPDA Call Out and Disconnect LPDA 2 commands The Call Out command instructs the DSU to set up dial backup from the control site and switch to the PSTN line The Disconnect command...

Страница 108: ...ommodate LPDA 2 monitoring on Port 1 NetView treats the TDM as a single point to point circuit and the MCMP as a single multipoint circuit For TDM LPDA 2 commands issued from NetView only affect Port...

Страница 109: ...Principles of Operation 4 57 3610 A2 GB41 70 July 1999 Figure 4 44 Multiplexing with TDM LPDA 2 Monitoring Figure 4 45 Multiplexing with MCMP LPDA 2 Monitoring...

Страница 110: ...rom the NetView operator s perspective the digital sharing feature appears as a unique DSU connected to each DTE The LPDA 2 address is set to the lowest PU address The DTE with the lowest PU address i...

Страница 111: ...Principles of Operation 4 59 3610 A2 GB41 70 July 1999 Figure 4 47 Digital Sharing in a Multipoint Circuit...

Страница 112: ...COMSPHERE 3600 Series Data Service Units 4 60 July 1999 3610 A2 GB41 70 Figure 4 48 Digital Sharing in a TDM Circuit LPDA 2 Monitoring...

Страница 113: ...Principles of Operation 4 61 3610 A2 GB41 70 July 1999 Figure 4 49 Digital Sharing in an MCMP Circuit LPDA 2 Monitoring...

Страница 114: ...COMSPHERE 3600 Series Data Service Units 4 62 July 1999 3610 A2 GB41 70...

Страница 115: ...regate Switch 5 13 Bridge 5 13 Test Branch 5 14 Abort 5 15 Device Test 5 15 Loopback 5 17 Local Loopback 5 17 DTE Loopback 5 19 Digital Loopback 5 20 Remote Digital Loopback 5 22 Bilateral Loopback 5...

Страница 116: ...ys indicate the key you should press to display the next screen in the example provided or the next screen in the procedure Refer to the COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 O...

Страница 117: ...faceplate provides additional device status and port selection information Table 5 1 describes the function of the TDM and MCMP faceplate indicators The DBM V DBM S and DBM D circuit cards are used wi...

Страница 118: ...3611 496 12349 01 Figure 5 2 Model 3611 DSU and MCMP Faceplates TXD RXD RTS CTS DSR DTR LSD 103 104 105 106 107 108 109 OK Alrm Test Dial Status Front Panel DBM S 3600 TXD RXD RTS CTS DSR DTR LSD 103...

Страница 119: ...s When the reload procedure is completed the Alrm LED goes Off and the TDM or MCMP OK LED comes ON Port 1 2 3 4 5 or 6 Green In TDM or MCMP mode 1 shows which port is being monitored the status of the...

Страница 120: ...nterface circuit designations Control circuit active or Data circuit SPACE ing For the DSU with TDM or MCMP the circuit external lead states for any of the TDM or MCMP ports can be selected from the D...

Страница 121: ...SU may vary depending upon the operating mode MUX Funct configuration option and the port selected Local Remote Menu Subbranches The Local branch menu has five subbranches and the Remote branch menu h...

Страница 122: ...fer to the menu in Appendix A You will see Port Select under some of the menu selections which means that a Port Number screen will appear when operating in TDM MCMP or Bridge mode Use the F1 and F2 k...

Страница 123: ...ke the following selections Local F1 or Remot F2 and Address Stat H S Devic Results When the digital circuit is the active link the first line displays a running normal operation timer hhh mm ss The s...

Страница 124: ...Stat DTE NOTE If there is only one port the DTE Status screen is displayed If there is more than one port the Port screen is displayed prior to the DTE Status screen If using FEP port sharing select...

Страница 125: ...est to send RTS lead and reports the DTE powered ON if the voltage is approximately less than 3V or greater than 3V for both EIA 232 and V 35 interfaces To access the Terminal Power report from the to...

Страница 126: ...e Options Applications Guide DBM DBM V DBM S DBM D This section discusses the full set of commands available in the Backup branch when a DBM is installed NOTE References to DBM in this guide also appl...

Страница 127: ...s when Bckup is selected With the addition of the TDM or MCMP circuit card the DCP operation remains unchanged while in Idle mode for the following Enabling disabling or placing the DBM in Dial Backup...

Страница 128: ...ate data stream test the entire bandwidth Therefore during aggregate tests in band secondary channel transport communication is lost For tests such as aggregate Digital Loopback DL the control DSU rep...

Страница 129: ...e DSU sends out polls to determine whether the DBM and MUX circuit cards are installed MUX indicates a TDM or MCMP The DSU then initiates a Device Test on itself and each of the available circuit card...

Страница 130: ...d of Pass Also the Alarm Alrm status indicator lights and the failure is reported in the DSU s Health and Status The Alarm indicator remains lit and the failure continues to be reported until the Devi...

Страница 131: ...o the DSU and verify that the DSU is functioning properly Figure 5 5 This test cannot be performed by the DBM Local loopback is used with the DTE test after the DSU passes the Device Test If you issue...

Страница 132: ...conclusion NOTE When Nondisruptive Diagnostics is enabled Diag Type NonD Local Loopback disrupts secondary channel transport communications For a control DSU the DSU may report No Response or Tributa...

Страница 133: ...access the DTE Loopback from the top level menu make the following selections Local F1 Test DSU or DBM select active core Lpbk DTE Port selection Results The test result is a message telling you whet...

Страница 134: ...ircuit between two DSUs DTE connections to the DSUs are not required For the DBM Digital Loopback is used to determine whether the DBM connection to the dial network is functioning properly Digital Lo...

Страница 135: ...ocal F1 Remot F2 and Address Test DSU or DBM select active core Lpbk DL Port Select when not operating in single port mode NOTE When the local DSU initiates Digital Loopback to a remote DSU via Remote...

Страница 136: ...trol or tributary DSU originates Remote Digital Loopback both originating and targeted DSUs enter Test mode On a multipoint circuit all tributaries are placed in Test mode No other test can be run at...

Страница 137: ...elections Local F1 Test DBM select active core Lpbk RL Port Select when not operating in single port mode Trib Address multipoint control DBM only For TDM or MCMP mode the following additional menu ap...

Страница 138: ...guration choice see the General Configuration Option Table in Chapter 6 of the COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Operator s Guide NOTE If the Bilat Lpbk Bilateral Loopback...

Страница 139: ...l transport data is not allowed to avoid disrupting in band secondary channel transport communications Selecting Prt1 allows both the test pattern and in band secondary channel transport data to propa...

Страница 140: ...COMSPHERE 3600 Series Data Service Units 5 26 July 1999 3610 A2 GB41 70 Figure 5 10 Digital Test...

Страница 141: ...tal Test results refer to the COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Dial Backup Module and SNA Diagnostic Interface Options Applications Guide End to End Test The End to End EE...

Страница 142: ...dule and SNA Diagnostic Interface Options Applications Guide Table 5 7 End to End Test Results Results Reported By1 Information Displayed Time Local and remote DBM Running test timer The Clr selection...

Страница 143: ...e BERT Port Select when not operating in single port mode or Aggr Selecting Aggr Aggregate allows the test pattern data to propagate the data path This is the same loopback configuration as Basic mode...

Страница 144: ...COMSPHERE 3600 Series Data Service Units 5 30 July 1999 3610 A2 GB41 70 Figure 5 12 Bit Error Rate Tests in TDM or MCMP Mode...

Страница 145: ...f any character indicator appears nonfunctional the DCP should be replaced If any of the LEDs do not work the circuit card should be replaced Pressing any key except the key will stop the LCD portion...

Страница 146: ...hat Usr1 and Usr2 are storage areas for user defined configuration option sets and that Usr3 is shipped from the factory loaded with the configuration option sets for a DBM V DBM S or DBM D Usr3 can b...

Страница 147: ...ration and access the MUX Setup submenu F1 Chang MUX Opts Copy Setup Prt1 F2 F3 Prt3 Prt4 Prt5 Prt6 Prt2 The Setup selection displays the first configuration option in the Setup option set MUX Funct w...

Страница 148: ...ds are set in the PrtSp submenu The DSU will not save configuration option selections if there is a mismatch in option settings Refer to the COMSPHERE 3600 Series Data Service Units Models 3610 and 36...

Страница 149: ...DSU Operations 5 35 3610 A2 GB41 70 July 1999 Figure 5 13 Choosing Mode of Operation and Setting Configuration Options...

Страница 150: ...st set to Disab Lowest Port Select lowest port number in the second digital sharing group X X1 Ignored Ports in Gp Select number of ports to be in the second digital sharing group X X1 Ignored Port Cn...

Страница 151: ...lues normally available to that option still appear but changes made have no effect the configuration option s value is not overwritten in software The Copy selection allows the set of configuration o...

Страница 152: ...tion is also called pseudo controlled carrier PCC mode X X Forced to Const RxCarrSel Enable the receiving DSU to look for V 13 codes on an individual channel that indicate transitions of RTS at the re...

Страница 153: ...you to change the primary and backup port speed configurations for TDM mode and the primary port speed and channel to port assignment configurations for MCMP mode For single port operation this option...

Страница 154: ...ndisruptive and mixed diagnostics To access PList from the top level menu make the following selections Local F1 Confg PList The following appears F1 Poll List Displ Clr Chang F2 F3 Acq Add Press the...

Страница 155: ...F2 F3 F1 Acquir Poll List Command Complete F2 F3 All tributary addresses have been acquired Directory The DSU s dial backup Directory Dir is available only if a DBM is installed and only from the Loc...

Страница 156: ...a remote site A local telephone number can contain any of the characters listed in Table 5 12 Remember that the telephone number cannot contain any separating characters or spaces although other vali...

Страница 157: ...DBM can be disabled if it is addressed from the Remote branch The Control branch menu has three selections Table 5 13 lists the selections on the Control branch menu Table 5 13 Control Branch Menu Op...

Страница 158: ...e top level menu make the following selections Local F1 or Remot F2 and Address Ctrl TxCtl The Transmitter Control submenu in Local mode differs from the one in Remote mode Assume Local mode in the fo...

Страница 159: ...s previously demonstrated LEDs The LEDs selection is only available from the Local branch This selection allows you to monitor any of the TDM or MCMP ports at any given time When a port is selected it...

Страница 160: ...port to a new selection You must select Save to have the entry accepted Results The DSU displays the following indicating that the command has been put into effect F1 Save LEDs Port 2 Command Complet...

Страница 161: ...A 1 3610 A2 GB41 70 July 1999 Data Service Unit Menu A...

Страница 162: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB41 70...

Страница 163: ...Data Service Unit Menu A 3 3610 A2 GB41 70 July 1999...

Страница 164: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB41 70...

Страница 165: ...M or MCMP operating in Bridge mode A Configuration Worksheet summarizes the DSU TDM s or DSU MCMP s option sets configuration options and configuration option values An explanation for each configurat...

Страница 166: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB41 70 This page intentionally left blank...

Страница 167: ...CC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab Antistream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on Tst Enab D...

Страница 168: ...18 0 16 8 14 4 12 0 9 6 9 2 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt6 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 9 2 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Underspeed Disab Prt1 Prt2 Prt3 Prt4 Prt5 Prt6...

Страница 169: ...8 9 10 Hardware Straps Value DDD Interface Permissive Programmable Frame Ground Signal Ground Connected Disconnected Test Mode Indication Enabled Disabled ChgMd Options Value Mode DPII ADp DMC Not ava...

Страница 170: ......

Страница 171: ...Mark PCC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab Antistream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on Tst...

Страница 172: ...ue Prt1 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt2 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt3 56 48 38 4 32 28 8...

Страница 173: ...Options Value Auto Bckup Enab Disab Backup Dir Chang 1 10 BckupOnCMI Enab Disab AutoRestor Enab Disab NtwkTimOut Chang min and sec RestorTimOut Chang min TriesTimeOut Chang min MultiCall Enab Disab H...

Страница 174: ......

Страница 175: ...rl Mark PCC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab Antistream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on T...

Страница 176: ...LatchLpbk On Off AggrSwitch Enab Disab AgSw Timing Int Aggr Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 V 54 Lpbk Enab Disab LPDA 2 Options Value LPDA 2 Enab Disab LPDA Address Chang 1 256 SNA Backup Enab Disab Cod...

Страница 177: ...r Type 2500 2600 3600s 3600e Br56 Diagnostic DBM Options Value Diag Type NonD Disr Mixed None 2nd Ch bps 100 400 800 1200 1600 RemoteDiag V 54 Enhan 2500 Diagnostic General Options Value Position Cntr...

Страница 178: ...or DBM D only DBM D only General Options Value DTE Port EIA232 V 35 RTS Cntrl FrcOn DTE CTS Cntrl Std RTS AnitStream Chang Disab 1 100 sec async terminal 1 100 LSD Lead Std Delay FrcOn CTS Lead Std De...

Страница 179: ...IA 232 D V 24 and V 35 connector pin assignments for Port 1 for all DSU TDMs and DSU MCMPs Figure C 4 and Figure C 5 show the V 35 adapters that are used with the standalone TDM DSD MCMP DSD TDM Flex...

Страница 180: ...1 1 of 3 Time Division Multiplexer Connector Used with Non Modular TDM 60 Position High Density Connector 25 Position Socket D Sub P1 Pin Port 1 Pin 01 J3 05 02 J3 17 03 J3 08 04 J3 06 05 J3 12 06 J3...

Страница 181: ...Position Socket D Sub P1 Pin Port 1 Pin 16 J2 20 17 J2 24 18 J3 07 19 J2 04 20 J5 02 21 J5 08 22 J2 12 23 J5 04 24 J6 07 25 J6 08 26 J6 06 27 J6 17 28 J6 03 29 J6 12 30 J4 07 31 J4 17 32 J4 02 33 J4...

Страница 182: ...plexer Connector Used with Non Modular TDM 60 Position High Density Connector 25 Position Socket D Sub P1 Pin Port 1 Pin 46 J2 06 47 J2 17 48 J2 05 49 J2 03 50 J5 06 51 J5 05 52 J5 17 53 J5 24 54 J5 2...

Страница 183: ...of 3 Digital Bridge Connector Used with Non Modular TDM MCMP 60 Position High Density Connector 25 Position Plug D Sub P1 Pin Port1 Pin 01 NC2 NC2 02 P3 24 03 P3 04 04 P3 20 05 NC2 NC2 06 P3 17 07 P3...

Страница 184: ...lug D Sub P1 Pin Port1 Pin 14 P2 03 15 NC2 NC2 16 P2 06 17 P2 17 18 P3 07 19 P2 08 20 P5 03 21 P5 04 22 NC2 NC2 23 P5 08 24 P6 07 25 P6 04 26 P6 20 27 P6 24 28 P6 02 29 NC2 NC2 30 P4 07 31 P4 24 32 P4...

Страница 185: ...MCMP 60 Position High Density Connector 25 Position Plug D Sub P1 Pin Pin Port1 45 NC2 NC2 46 P2 20 47 P2 24 48 NC2 NC2 49 P2 02 50 P5 20 50 P5 20 51 NC2 NC2 52 P5 24 53 P5 17 54 P5 06 55 NC2 NC2 56 N...

Страница 186: ...COMSPHERE 3600 Series Data Service Units C 8 July 1999 3610 A2 GB41 70 Figure C 3 Pin Locations on the 60 Position High Density Connector of the Non Modular Carrier Mounted TDM MCMP Circuit Card...

Страница 187: ...5 40 36 44 55 DB 114 Transmitter Signal Element Timing DCE Source 47 2 31 52 27 DD 115 Receiver Signal Element Timing DCE Source 16 7 39 54 59 CD 108 2 Data Terminal Ready DTR 17 6 38 53 60 DA 113 Tra...

Страница 188: ...E Source alternate external control lead II 15 DB 114 Transmitter Signal Element Timing DCE Source 17 DD 115 Receiver Signal Element Timing DCE Source 18 LL 141 Local Loopback LL 191 Data Signal Rate...

Страница 189: ...eady DSR F CF 109 Received Line Signal Detect LSD H CD 108 2 Data Terminal Ready DTR HH Positive Test Voltage KK Negative Test Voltage U W DA 113a b Transmitter Signal Element Timing DTE Source Y AA D...

Страница 190: ...COMSPHERE 3600 Series Data Service Units C 12 July 1999 3610 A2 GB41 70 99 16294 Figure C 4 Modular DSU V 35 Adapter Plug Figure C 5 Modular DSU V 35 Adapter Cable Feature Number 3000 F1 510...

Страница 191: ...est to Send RTS 5 D Clear to Send CTS 6 E Data Set Ready DSR 8 F Received Line Signal Detect LSD 20 H Data Terminal Ready DTR 21 J Ring Indicator RI 24 11 P S Transmit Data TXD 23 22 R T Received Data...

Страница 192: ...COMSPHERE 3600 Series Data Service Units C 14 July 1999 3610 A2 GB41 70 Figure C 6 6 Port Connector Module Part Number 870 1700 0011...

Страница 193: ...al Element Timing DCE Source 17 DD 115 Receiver Signal Element Timing DCE Source 20 CD 108 2 Data Terminal Ready DTR 24 DA 113 Transmitter Signal Element Timing DTE Source 1 EIA 232 refers to EIA 232...

Страница 194: ...COMSPHERE 3600 Series Data Service Units C 16 July 1999 3610 A2 GB41 70 Figure C 7 6 Port V 35 Interconnect Cable Feature Number 3600 F3 500...

Страница 195: ...E Data Set Ready DSR 8 F Received Line Signal Detect LSD 20 H Data Terminal Ready DTR 22 J Ring Indicator RI 1 18 L Local Loopback LL 21 N Remote Digital Loopback RL 2 14 P S Transmit Data TXD 3 16 R...

Страница 196: ...COMSPHERE 3600 Series Data Service Units C 18 July 1999 3610 A2 GB41 70...

Страница 197: ...ption settings needed to support that scenario Refer to Chapter 5 for additional configuration information When reviewing the configuration options keep the following in mind A set of configuration op...

Страница 198: ...ntral site and the terminals and printer at the remote site The second scenario shows full backup of TDM circuits using Switched 56 DBMs TDM Scenario 1 Using Two Synchronous Channels In this configura...

Страница 199: ...Disab P3 4 FEPSh Disab P5 6 FEPSh Disab Prt1 and Prt2 Prt3 through Prt6 N A Async Sync Disab TxCarrSel Const RxCarrSel Const Elast Stor Disab RTS CTS Del 0 AntiStream Disab PrtSp DSU Prt1 7 2 Prt2 2...

Страница 200: ...red for automatic dial backup and automatic restoration for both the control and the tributary and LPDA 2 is enabled Make sure that you enter at least 2 minutes difference between the control s Networ...

Страница 201: ...control Trib for tributary LinkConfig Pt Pt Diag Conn CC for control N A for tributary DBM AutoAnswer Enab Call Setup Pswrd RxPwd enter received password TxPwd enter transmit password V 13 Signl Disab...

Страница 202: ...gital bridge The control and tributary DSUs are configured for mixed diagnostics Tributary DBMs are configured for 9 6 kbps operation automatic backup no fallback backup on network fault Network Time...

Страница 203: ...bps It is not likely that backup can be accomplished before the network has timed out and the affected tributaries have been taken off the host s active list However if they are placed on an FEP s sl...

Страница 204: ...and DBM are configured for password security Call Setup PsWrd the DBM V s outgoing password TxPwd must be the same as the tributary DBM s incoming password RxPwd The network can be tested by performin...

Страница 205: ...ime Gen DTE Port EIA232 Set configuration options for automatic partial backup using the DBM V as follows Configuration Worksheet for Basic DBM V DBM S or DBM D Mode Diag DBM Diag Type Disr RemoteDiag...

Страница 206: ...EIA232 RTS Cntrl DTE CTS Cntrl Std Bkup Auto Bckup Enab Backup Dir enter Dir number 1 to 10 BckupOnCMI Enab AutoRestor Enab NtwkTimOut enter 1 minute RestorTimOut enter 5 minutes TriesTimOut enter 1...

Страница 207: ...nnected the pair of DBMs perform a handshake and exchange passwords then enter Data mode ready to send data After the tributary DSU DBM has set up the call each DSU switches the DTE s data to its DBM...

Страница 208: ...e nondisruptive diagnostics configuration Please note that all DBM Ss here should be configured the same only the passwords and telephone numbers should differ The same holds true for the tributary DS...

Страница 209: ...56 TxClkSource DDS AggrSwitch Disab Diag DSU Diag Type NonD Disr Type Br56 Diag DBM Diag Type NonD RemoteDiag Enhan Diag Gen Position Trib LinkConfig M Pt Resp Period 1 M Pt SymPrt Disab DBM PrtSp Kbp...

Страница 210: ...ol DSU and a Tributary Time out alarm for each tributary DSU and DBM It is assumed that a failure in the DDS network is not between the control DSU and the central office The control DSU still receive...

Страница 211: ...Configuration Scenarios D 15 3610 A2 GB41 70 July 1999 Figure D 7 Extended Bridge Configuration Automatic Partial Backup Dial Backup Not Active...

Страница 212: ...COMSPHERE 3600 Series Data Service Units D 16 July 1999 3610 A2 GB41 70 Figure D 8 Extended Bridge Configuration Automatic Partial Backup Active Dial Backup Active for All Drops...

Страница 213: ...Configuration Scenarios D 17 3610 A2 GB41 70 July 1999 Figure D 9 Extended Bridge Configuration Automatic Partial Backup Active Dial Backup Active for Two Drops...

Страница 214: ...ommunicating when the switch occurs Pertinent configuration options for the central site bridge and the extended bridge that support the configuration scenario just described follow The configuration...

Страница 215: ...tributary DSUs are configured for nondisruptive diagnostics with a 400 bps in band secondary channel transport speed Seven central site DBM Vs are dedicated to the control DSU and are connected to it...

Страница 216: ...COMSPHERE 3600 Series Data Service Units D 20 July 1999 3610 A2 GB41 70 Figure D 10 NMS Controlled Full Backup Configuration Dial Backup Not Active...

Страница 217: ...Configuration Scenarios D 21 3610 A2 GB41 70 July 1999 Figure D 11 NMS Controlled Full Backup Configuration Dial Backup Active...

Страница 218: ...backup circuit and the host computer can restart the network polling When backup is completed the FEP line may be restarted if necessary During backup the DSU still reports the facility alarm to the N...

Страница 219: ...nD 2nd Ch bps 400 Disr Type 3600 Diag Gen Position Cntrl LinkConfig M Pt Trib TimOut enter amount of time Diag Conn CC M Pt SymPrt Disab Gen DTE Port V 35 Set the extended bridge configuration options...

Страница 220: ...RTS Cntrl FrcOn CTS Cntrl Std Bkup Auto Bckup Disab AutoRestor Disab Set the configuration options for multipoint full dial backup of a tributary DSU as follows Configuration Worksheet for Basic Mode...

Страница 221: ...s services automated teller machines ATMs Channel C In addition the low speed application extended via the FEP port sharing feature of the control DSU and a dedicated multipoint circuit services sever...

Страница 222: ...COMSPHERE 3600 Series Data Service Units D 26 July 1999 3610 A2 GB41 70 Figure D 12 MCMP using FEP Port Sharing Configuration...

Страница 223: ...to the extended bridge The central site DBM Ss are configured for disruptive diagnostics Diag Type Disr The extended bridge is configured to operate at 56 kbps automatically taking its timing from any...

Страница 224: ...the Standby Facility State field command followed by a dial and a q command in the Number to Dial field to each DBM S associated with the digital bridge To end the backup session via the SDCP address...

Страница 225: ...Del 0 DTR Alarm Disab DSU TxElastStor Enab AggrSwitch Disab Diag DSU Diag Type Disr Disr Type 3600e Diag Gen Position Cntrl LinkConfig M Pt Gen DTE Port V 35 Set configuration options for automatic p...

Страница 226: ...e DBM s are configured for 14 4 kbps Excess bandwidth must be reserved on the backup configuration so that framing and diagnostic data does not reduce the port speeds Therefore the DBM port speeds are...

Страница 227: ...us use the Sharing Device configuration options Upstream switched carrier configurations must be set TxCarrSel set to Cntrl and RxCarrSel set to Cntrl or Mark in TDM mode use the system default settin...

Страница 228: ...Gen Position Cntrl for control Trib for tributary LinkConfig M Pt DBM Rate Kbps N A for control 14 4 for tributary TxClkSource N A for control RXC for tributary CarrLossDisc N A for control Yes for tr...

Страница 229: ...Sel Const RTS CTS Del 0 DTR Alarm Disab AntiStream Disab PrtSp DSU Prt1 7 2 Prt2 7 2 Prt3 4 8 Prt4 4 8 Prt5 and Prt6 Disab Diag DSU Diag Type NonD 2nd Ch bps 40 Disr Type 3600e Diag Gen Position Cntrl...

Страница 230: ...COMSPHERE 3600 Series Data Service Units D 34 July 1999 3610 A2 GB41 70...

Страница 231: ...ynchronous operation 1 3 1 4 sources 4 6 automatic DDS restoration 4 47 partial backup D 6 D 7 D 15 active D 16 D 17 extended bridge D 14 B backup aggregate switched MCMP circuits 4 34 TDM circuit 4 2...

Страница 232: ...MP 4 26 management 4 23 speeds 1 4 4 23 underspeed 4 6 circuit backbone TDM 4 11 quality 5 11 measurements 5 11 COMSPHERE 3000 Series Carrier rear 3 10 configuration branch 5 7 5 31 options 3 4 mode o...

Страница 233: ...lity 1 5 configuration scenarios D 6 connector C 5 non modular TDM MCMP C 5 DBM V DBM S DBM D interface 4 46 switched LSD operation 4 46 DCE interface 4 33 DSU interface 4 52 inactive central site bri...

Страница 234: ...ring 1 3 1 4 4 14 4 15 4 32 backup D 30 configuration dial backup active D 31 MCMP 4 27 D 25 D 26 flex interface switch 2 6 framing bit 4 6 in band 4 6 management channel 4 23 front panel model 3611 5...

Страница 235: ...ve D 31 flex 2 port 6 port 1 4 independent channels 4 26 initialization 4 25 LPDA 2 interoperability 1 5 mode 4 4 multiplexing 4 56 4 57 operation 4 25 overhead composition 4 23 signal flow 4 24 statu...

Страница 236: ...3 1 5 4 52 full backup configuration D 20 full backup configuration D 21 software configuration 2 11 3 4 non modular carrier mounted pin locations C 8 DSU with TDM MCMP 3 2 TDM connector C 2 TDM MCMP...

Страница 237: ...software configuration DCP or NMS 2 10 SDCP 3 4 speeds channel 4 23 characteristics 4 6 line 4 23 standard features 1 2 status branch 5 7 5 8 codes DTE lead 5 10 indicators 5 3 DBM V DBM S DBM D 5 6 D...

Страница 238: ...7 5 14 device 5 15 digital 5 25 end to end 5 27 lamp 5 31 results bit error rate 5 29 digital 5 27 end to end 5 28 transmission multipoint 4 3 point to point 4 2 transmitter control 5 44 tributary add...