Operation
3-21
3160-A2-GB22-10
December 1996
To protect you from accidentally exiting an edit session
before saving your changes, the system prompts Save
Options? if you select either Main or Cntrl-x from an
edit screen (see Figure 3-18). If you respond No, the
system exits without saving the changes. If you respond
Yes, you are prompted to specify where the changes
should be saved.
Customer ID: New Cust
main/control/miscellaneous
Model: ACCULINK XXXX
Save Main Previous Cntrl–x to Disconnect
Miscellaneous Control Options
Customer Identification Name/Number: _____
Password: _____
Change Password: _____
Re–enter Password: _____
Yes
Figure 3-18. Save Edit screen
NOTE
If you terminate async terminal
control by changing the
configuration interface options,
the async terminal must be
reconfigured on the port.
Selecting/Copying to a Specific Port
You have the capability of selecting a specific port to
configure and to copy the configuration options for one
port to another port or to all ports. You can use the
configuration worksheets provided to note the
configuration options you have chosen (see Figure 3-19).
Selecting a Specific Port
To select a specific port to configure,
1. Press F3 to select Cnfig from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key. Use the scroll keys, if necessary.
F1
Load from:
Activ
Cust
Fact1
F2
F3
3. Press F1 to select Edit.
F1
Choose Funct:
Edit
Save
F2
F3
4. Press F2 to select Port.
F1
Edit:
DTE
Port
NET
F2
F3
5. From the Port Select screen, press the Function
key that corresponds to the desired port. Use the
key to scroll addition ports onto the screen, if
necessary.
F1
Port Select:
Copy
Prt1
Prt2
F2
F3
Содержание ACCULINK 316x
Страница 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Страница 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Страница 38: ...Installation 2 15 3160 A2 GB22 10 December 1996 Figure 2 13 3160 3164 DSU CSU Cabling Configurations...
Страница 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Страница 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Страница 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Страница 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...
Страница 175: ...Pin Assignments D 11 3160 A2 GB22 10 December 1996 Figure D 7 EIA 530A to RS449 Adapter Cable Feature Number 3100 F1 580...
Страница 177: ...Pin Assignments D 13 3160 A2 GB22 10 December 1996 Figure D 8 EIA 530A to V 35 Adapter Cable Feature Number 3100 F1 570...