ACCULINK 316x DSU/CSU
3-16
December 1996
3160-A2-GB22-10
Table 3-6
Test Jack Functions
Test Jack Name
Function
Net In
(Network In)
A break-in and test jack that allows a signal to be inserted toward the network by
external test equipment. The signal is inserted on the DSX-1 side of the
DSU/CSU.
Net Out
(Network Out)
A break-in and test jack that interrupts the signal coming from the network and
allows it to be terminated by the external test equipment.
Net Mon In
(Monitor Network)
A monitor jack that nonintrusively monitors the incoming signal from the network.
Net Mon Out
(Monitor DSX-1)
A monitor jack that nonintrusively monitors the incoming signal from the DSX-1.
Eqp Mon Net
(Equipment In)
A break-in and test jack that allows a signal to be inserted toward the DSX-1 by
external test equipment.
Eqp Mon Eq
(Equipment Out)
A break-in and test jack that interrupts the signal coming from the DSX-1 and
allows it to be terminated by the external test equipment.
Configuring the DSU/CSU
You have the option of customizing your 316x
DSU/CSU for optimum performance in your network. To
do so, use the DSU/CSU configuration options.
Appendix G contains a set of blank worksheets to use
when configuring your 316x DSU/CSU in the network.
Configuration Option Areas
The 316x DSU/CSU offers four sets of configuration
options located in the following areas:
•
Active (Activ). The configuration option set active
for the DSU/CSU is stored here. Before a set of
configuration options become active for the
DSU/CSU, you must save the set to the Active area.
When the DSU/CSU is shipped from the factory,
the Active configuration option set is identical to
both the Customer and the Factory 1 sets. This area
can be written to and controls the current operation
of the device.
•
Customer (Cust). This is the set of
customer-defined configuration options. Customer
set is identical to the Factory 1 set when the
DSU/CSU is shipped from the factory. This area
can be written to.
•
Factory 1 (Fact1). This is a set of configuration
options preset at the company. This set is
determined by what is considered to be the most
common configuration used in the DSU/CSU
market. Factory 1 options are read-only.
•
Factory 2 (Fact2). This is a set of configuration
options preset at the company. This set is
determined by what is considered to be the second
most common configuration used in the DSU/CSU
market. Factory 2 options are read-only.
Configuration Options
The configuration options are divided into seven
functional groups. Appendix C contains a list of the
configuration options and defaults. These groups are:
•
DTE (DSX-1) Interface (see Table C-1)
•
Port (see Table C-2)
•
Network Interface (see Table C-3)
•
Channel (see Tables C-4 and C-5)
•
General (see Table C-6)
•
User Interface (see Table C-7)
•
Alarm (see Table C-8)
•
General SNMP (see Table C-9)
•
SNMP Trap (see Table C-10)
Содержание ACCULINK 316x
Страница 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Страница 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Страница 38: ...Installation 2 15 3160 A2 GB22 10 December 1996 Figure 2 13 3160 3164 DSU CSU Cabling Configurations...
Страница 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Страница 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Страница 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Страница 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...
Страница 175: ...Pin Assignments D 11 3160 A2 GB22 10 December 1996 Figure D 7 EIA 530A to RS449 Adapter Cable Feature Number 3100 F1 580...
Страница 177: ...Pin Assignments D 13 3160 A2 GB22 10 December 1996 Figure D 8 EIA 530A to V 35 Adapter Cable Feature Number 3100 F1 570...