ACCULINK 316x DSU/CSU
4-14
December 1996
3160-A2-GB22-10
Aborting Test Patterns
Use the Abort command to stop all test patterns or any
selected test pattern active on the DSU/CSU.
To abort test patterns,
1. Press F2 to select Test from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. From the Test screen, press F3 to select Ptrns.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Patterns screen, press F1 to select Abort.
F1
Patterns:
Abort
Send
Mon
F2
F3
4. From the Patterns Abort screen, press the desired
function key to abort either All active test patterns,
active Send test patterns, or the active Monitor
(Mon) test pattern.
F1
Patterns: Abort
All
Send
Mon
F2
F3
If you select All, the DSU/CSU terminates all
active test patterns and displays the message
Command Complete. Skip Step 5.
NOTE
Be careful when selecting a specific
test pattern to abort. If you mistakenly
choose to abort a test pattern that is
not currently running, a Command
Complete message still displays and
the test pattern currently active still
runs. You can use the TStat branch of
the menu to view the test status to
determine if the abort was successful.
5. From the Abort screen, press the function key that
corresponds to the network or port for which you
want to abort a test pattern. Use the scroll keys, if
necessary.
F1
Abort:
Send or Mon
NET
Prt1
Prt2
F2
F3
The DSU/CSU terminates the selected test pattern
and displays the message Command Complete.
Lamp Test
Use the Lamp Test commands to start and stop a test of
the DSU/CSU front panel LEDs. This feature is only
available from the front panel.
Starting a Lamp Test
To start a Lamp test,
1. Press F2 to select Test from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
Содержание ACCULINK 316x
Страница 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Страница 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Страница 38: ...Installation 2 15 3160 A2 GB22 10 December 1996 Figure 2 13 3160 3164 DSU CSU Cabling Configurations...
Страница 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Страница 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Страница 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Страница 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...
Страница 175: ...Pin Assignments D 11 3160 A2 GB22 10 December 1996 Figure D 7 EIA 530A to RS449 Adapter Cable Feature Number 3100 F1 580...
Страница 177: ...Pin Assignments D 13 3160 A2 GB22 10 December 1996 Figure D 8 EIA 530A to V 35 Adapter Cable Feature Number 3100 F1 570...