Configuration Option Tables
A-2
7612-A2-GB20-00
June 1997
Select . . .
To Access the . . .
To Configure the . . .
System
System Options
, Table A-1
General system
options
Network
Network Interface Options
, Table A-2
DDS network interface
Data Port
Data Port Options
, Table A-3
DTE port
Ethernet Port
Ethernet Port Options
, Table A-4
10BaseT port
Terminal Port
Terminal Port Options
, Table A-5
Terminal port
Telnet Session
Telnet Session Options
, Table A-6
Telnet user interface
SNMP
General SNMP Management Options
,
Table A-7
SNMP NMS Security Options
, Table A-8
SNMP Traps Options
, Table A-9
Management support
through SNMP
All changes to configuration options must be saved. Refer to
Saving
Configuration Options
in Chapter 3.
System Options Menu
For System Options, refer to Table A-1. To access the System Options screen,
follow this menu selection sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
Edit
→
System
Table A-1.
System Options (1 of 3)
Operating Mode
Possible Settings: DDS, LADS
Default Setting: DDS
The unit’s operating mode depends upon the DSU’s application.
DDS – Standard DDS network operation. The operating rate is either 56 kbps or
64 kbps CC.
LADS – The Local Area Data Set operating mode requires that the local and remote
units are connected directly to each other. This is a point-to-point application; also
known as LDM.