Monitoring the DSU
6-8
7612-A2-GB20-00
June 1997
Table 6-1.
Health and Status Messages (2 of 2)
Message
What To Do
What Message Indicates
In-band Mgmt
Channel Fail
The IMC is not operational.
Enable the IMC on the remote unit.
Device Fail
yyyyyyyy
An internal error has been
detected by the operating
software.
yyyyyyyy indicates
the 8-digit hexadecimal failure
code.
1. Provide the 8-digit failure code
shown (
yyyyyyyy ) to your service
representative.
2. Use the Clear command to clear
the message.
3. Reset the DSU to clear the
condition and message.
Ethernet Link
Down
The DSU detects no electrical
activity on the 10BaseT port.
1. Verify that the Ethernet cable is
securely attached at both ends.
2. Contact your LAN support
technician if problem persists.
DSU Operational
The DSU is functioning
properly and there are no
status messages to display.
No action required.
Self-Test Results
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 6-2.
Self-Test Results Messages
Message
What Message Indicates
What To Do
Device Fail
One or more of the DSU’s integrated
circuit chips has failed device-level
testing.
1. Reset the DSU and try again.
2. Use the Clear command to
clear the message.
3 Call your service
Memory Fail
DSU failed memory verification.
3. Call your service
representative for assistance if
the message reappears.
Passed
The DSU has been plugged in or
reset and has passed the diagnostic
test. There are no other status
messages.
No action required.