Installing POTS Splitter Modules in the POTS Splitter Chassis

Procedure

If POTS splitter modules are not installed in the chassis:

1. From the front of the chassis, slide a module into a free bay while holding the 

plastic locking tab in the downward, unlocked position. 

2. Ensure that the bottom of the locking tab enters its slot in the base of the 

chassis as you slide in the module.

3. Press the locking tab into its upright, locked position.

4. Repeat for all the modules you have to install.

Figure 1.

5910 POTS Splitter – Front

Figure 2.

5910 POTS Splitter – Rear

DSL

DSL

DSL

DSL

DSL

DSL

DSL

DSL

05-17653

Locking Tab

DSL 

Connector

05-17654

PSTN

Line

Line

Содержание 5910

Страница 1: ...s addresses specific issues that affect video flow such as crosstalk and ring trip problems The 5900 Series is environmentally hardened to handle such locations as remote cabinets as well as Central Offices Product Related Documents Paradyne documents are available on the World Wide Web at www paradyne com Select Library Technical Manuals To order a paper copy of a Paradyne document or to speak wi...

Страница 2: ...ever take proper static control precautions to prevent damage to equipment If you are not sure of the proper static control precautions contact your nearest sales or service representative The installation location should be well ventilated clean and free of environmental extremes Allow clearance at the front and back of the POTS splitter chassis to provide access to the cables Read the Important ...

Страница 3: ...h the self retaining nuts 5 Holding the chassis in place loosely install the bottom screws first and then the top screws 6 Tighten all screws firmly using a Phillips screwdriver Repeat the process for each POTS splitter chassis POTS splitter chassis can be mounted directly on top of each other Installation into a Rack with Threaded Screw Holes Procedure To install a chassis in a rack with threaded...

Страница 4: ...the plastic locking tab in the downward unlocked position 2 Ensure that the bottom of the locking tab enters its slot in the base of the chassis as you slide in the module 3 Press the locking tab into its upright locked position 4 Repeat for all the modules you have to install Figure 1 5910 POTS Splitter Front Figure 2 5910 POTS Splitter Rear DSL DSL DSL DSL DSL DSL DSL DSL 05 17653 Locking Tab DS...

Страница 5: ...your modem documentation Grounding To comply with the Network Equipment Building Systems NEBS requirements a suitable ground must be provided The 5910 can be grounded to the rack through the mounting brackets eliminating the need for a separate ground wire Grounding lugs are provided on the rear of the splitter modules to provide an accessible termination point for cable shield 25th pair grounds O...

Страница 6: ...each module 50 Position Telco Connector POTS Splitter Pin Ring Pin Tip 1 1 26 2 2 27 3 3 28 4 4 29 5 5 30 6 6 31 7 7 32 8 8 33 9 9 34 10 10 35 11 11 36 12 12 37 13 13 38 14 14 39 15 15 40 16 16 41 17 17 42 18 18 43 19 19 44 20 20 45 21 21 46 22 22 47 23 23 48 24 24 49 Pin 25 98 15482 01 Pin 1 Pin 50 Pin 26 ...

Страница 7: ... telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone l...

Страница 8: ...www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyn...

Отзывы: