Spectra 1727 7
4.5.2
O
NE
-
TOUCH
A
RMING
Section [19] options [3] and [5]
The One-touch Arming Feature allows users to Regular or Stay Arm the system without having to enter access codes. To arm the system, press
and hold the
[
ENTER
]
key for approximately 2 seconds. For more information concerning Regular and Stay Arming see section 6.2 and section
6.3.
Option
[3]
OFF
:
One-touch Arming is Regular Arming (default)
Option
[3]
ON
:
One-touch Arming is Stay Arming
Option
[5]
OFF
:
One-touch Arming is disabled (default)
Option
[5]
ON
:
One-touch Arming is enabled
4.5.3
S
TAY
A
RMING
WITH
D
ELAY
Section [19] option [8]
When Stay Arming (see section 6.3) with this option enabled, all armed zones become Entry Delay zones. For example: the system is Stay
Armed and you trigger a motion detector that is not a Stay Zone. Normally the system would go into alarm, but, since all armed zones are Entry
Delay Zones, the system starts the Entry Delay Timer to allow you time to disarm the system.
Option
[8]
OFF
:
Stay Arming with Delay disabled (default)
Option
[8]
ON
:
Stay Arming with all armed zones as Entry Delay zones
4.6
RESET JUMPER
Section [20] option [1]
Performing a jumper reset will clear and reset the Installer Code. To do so:
1)
Enable option
[1]
in section
[20]
.
2)
Remove battery and AC power from the control panel.
3)
Set the
RESET
jumper to on by placing a jumper on the
RESET
pins of the control panel.
4)
Re-connect AC and battery power to the control panel.
5)
Wait 10 seconds and remove the jumper.
6)
Disable option
[1]
in section
[20]
(Recommended).
Option
[1]
OFF
:
Reset Jumper disabled
Option
[1]
ON
:
Reset Jumper enabled (default)
As a preventive measure, we recommend that you remove the jumper, or turn off option
[1]
to avoid losing the Installer Code in the case
of an unexpected power loss.
4.7
BELL RELAY OPTION
Section [20] option [3]
When option
[3]
is enabled, the Bell Relay remains in its normal state. When an alarm occurs, it will toggle to its opposite state. When option
[3]
is disabled, the Bell Relay remains in its opposite state. When an alarm occurs, it will toggle to its normal state.
Option
[3]
OFF
: The Bell Relay deactivates upon alarm
Option
[3]
ON
:
The Bell Relay activates upon alarm (default)
5:
ACCESS CODES
5.1
ACCESS CODE LENGTH
Section [19] = System Options
Option
[4]
OFF
:
6-Digit Access Codes (default)
Option
[4]
ON
:
4-Digit Access Codes
All the access codes can be set to lengths of 4-or 6-digits. When the 4-digit option is selected, entering a 4-digit code will allow access. If the 6-
digit option is selected, a 6-digit access code is required. If the Access Code Length is changed from four digits to six digits when access codes
have already been programmed, the control panel will automatically add 00 to the end of the code. For example, if the access code is 1234 and
you switch to 6 digits, the code will become 123400. Be sure to verify the access codes after switching from 4-digit access codes to 6-digit codes.
When switching from six digits to four digits, the control panel will simply remove the final two digits of the access code. For example, 123456 will
become 1234.
5.2
INSTALLER CODE (DEFAULT: 0000/000000)
The
Installer Code
is used to enter the control panel's programming mode (see section 1.3) and program section
[01]
and sections
[10]
to
[20]
. The
Installer Code
can be 4 or 6 digits in length (see section 5.1) where each digit can be any value from 0 to 9. The
Installer Code
cannot
be used to program the
Master
or
User Access Codes
. To program the
Installer Code
press:
[
ENTER
]
+
[
CURRENT
INSTALLER
CODE
]
+
[01]
+
new 4- or 6-digit Installer Code
5.3
SYSTEM MASTER CODE (DEFAULT 1234/123400)
The
System Master Code
can program the
User Access Codes
in sections
[02]
to
[09]
,
but not the
User Code Options
see Table 4 on page 10
since they are pre-programmed and cannot be changed. The
System Master Code
can be 4 or 6 digits in length (see section 5.1), where each
digit can be any digit from 0 to 9. To change the
System Master Code
press:
[
ENTER
]
+
[
CURRENT
SYSTEM
MASTER
CODE
]
+
[02]
+
new 4- or 6-digit System Master Code
Содержание SPECTRA 1686H
Страница 1: ...SPECTRA 1727 V1 10 1727 COMPLETE INSTALLATION MANUAL Reference Installation and Programming...
Страница 2: ......
Страница 15: ...Spectra 1727 13 8 HARDWARE CONNECTIONS Figure 8 1 PCB Layout...
Страница 16: ...14 Complete Installation Manual Figure 8 2 Zone Connections Figure 8 3 PGM Connections...
Страница 18: ...16 Complete Installation Manual Notes...
Страница 19: ......
Страница 20: ......