background image

[5]

[2]

[4]

[2

]

ND

[1]

[3]

[6]

[11]

[11]

[8]

[10]

[10]

[7]

[9]

[12]

[12]

- 9 -

stay arm / System A

enabled
enabled

Bell squawk on arm/disarm
Auto zone shutdown

See "Reporting" table

(1:1.5) Pulse USA

(1:2) Pulse Europe

enabled

enabled
enabled

Auto arm on time
Auto arm on no movement

[5]

[2]

Keyswitch = regular arm

[4]

enabled

Call back

[2

]

ND

[1]

See "TLM" table

[3]

enabled

Keyswitch arming

[6]

generates only a report

Silent zone/panic generates a silent alarm

[11]

[11]

[8]

[10]

[10]

[7]

Pulse dialing
Partitioning

Tone dialing (DTMF)
enabled

[9]

[12]

[12]

086:

KEY

OFF

/

ON

OFF

/

ON

only after alarm

audible

enabled

audible

enabled

fire

on zone closure

4 digit

enabled
enabled

enabled

088:

OFF

/

ON

OFF

/

ON

enabled

enabled

KEY

no EOL

Report zone restore on bell cut-off

Tamper Recognition

Automatic event buffer transmission

Always report disarm

Panic 2 silent

Panic 1 silent

Panic 3 silent

6 digit access codes

Key

regular arm

[10]

Key

stay or system A arm

[11]

Beep on exit delay

Zones with EOL (1K )

W

(keys

&

)

[1]

[3]

(keys

&

[4]

[6])

(keys

&

)

[7]

[9]

Address 086, Key [2 ] [1]

ND

REPORTING OPTIONS

Regular reporting

Reporting disabled

Split reporting: Alarms

System report

Double reporting

1,2,1,2,1,2,1,2, fail to comm.

1,1,1,1,1,1,1,1, fail to comm.

2,2,2,2,2,2,2,2, fail to comm.

1,1,1,1,1,1,1,1, fail to comm.,
2,2,2,2,2,2,2,2, fail to comm.

*

On alarm, all reports are made to Tel. #1 until system is disarmed.
(Once disarmed, system reports are made to Tel. #2)

*

Address 086, Key [11] [12]

N/A

N/A

090:

Exclude power failure from trouble display

OFF

/

ON

OFF

/

ON

[3]

[1]

enabled

[2]

stay / System A

Auto arm = regular arm

KEY

[6]

tamper follows zone bypass definition

No tamper bypass

[5]

[4]

enabled

enabled

enabled

enabled

[7]
[8]
[9]

[10]
[11]
[12]

FEATURE SELECT PROGRAMMING

(continued)

(On/off status of key lights determines which feature is selected.)

Keypad 1 zone supervision

Audible trouble warning

Duress

Keypad 2 zone supervision

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A

N/A

Keypad software versions prior to

4.0

Keypad supervision must be

OFF

}

Keypad software versions

onward

4.0

Keypad supervision must be

ON

}

(See Wiring Diagram)

PG748ES

TAMPER / WIRE FAULT DEFINITIONS

**

**

Address 088, Key [10] [11]

*

*

Содержание Esprit 748ES

Страница 1: ...ON PROGRAMMING Can be used to program sections 00 to 67 addresses 000 to 043 and 300 to 527 Press ENTER installer code and 7 2ND and ENTER keys alternately flash Enter a 2 digit section number followe...

Страница 2: ...RAL STATION TELEPHONE NUMBER 2 View at addresses 024 to 031 06 __ __ __ __ __ __ __ __ 07 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ACCOUNT A AND B View at addresses 032 to 035 08...

Страница 3: ...2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 2 2 1 2 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 1 1 2 2 2 1 ND ND ND ND ND ND ND ND ND ND ND ND ND BYP ND MEM ND TRBL ND BYP MEM TRBL ND P...

Страница 4: ...6 304 305 306 307 ___ ___ ___ ___ _ ___ ___ ___ __ User code 27 User code 28 User code 29 User code 30 328 329 330 331 12 18 User code 7 User code 8 User code 9 User code 10 User code 15 User code 16...

Страница 5: ...9 User code 20 360 361 362 363 368 369 370 371 26 28 User code 33 User code 34 User code 35 User code 36 User code 41 User code 42 User code 43 User code 44 User code 45 User code 46 User code 47 User...

Страница 6: ...__ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 44 50 46 52 Zone 21 Zone 22 Zone 23 Zone 24 Zone 21 Zone 22 Zone 23 Zone 24 444 445 446 447 468 469 470 471 ___ _...

Страница 7: ...value will be displayed on keypad 4 Enter 3 digit DECIMAL value 5 Repeat from step 2 onward for next address To exit programming mode press CLEAR 044 ___ ___ ___ hours Auto arm time between 000 and 0...

Страница 8: ...conds and 129 to 255 for minutes factory default 5 seconds Add 128 to desired value in minutes i e for 5 minutes enter 5 128 133 057 ___ ___ ___ Intellizone delay in seconds minimum 10 seconds factory...

Страница 9: ...s 4 6 keys 7 9 Address 086 Key 2 1 ND REPORTING OPTIONS Regular reporting Reporting disabled Split reporting Alarms System report Double reporting 1 2 1 2 1 2 1 2 fail to comm 1 1 1 1 1 1 1 1 fail to...

Страница 10: ...nter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes MEM Panel time and clear trouble 8 all 3 codes Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes BYP Te...

Страница 11: ...ff reset key 11 off reset N C and or N O contacts see Figure 2 ZONE connection without EOL resistor with tamper recognition N C contacts address 088 key MEM on key 10 key 11 Tamper transmits separate...

Страница 12: ...detector PGM Z3 AUX 1K EOL W Smoke detector must be 4 wire latching UL Falcon model 5454 ULC BRK 2412 Power supervision relay model MR3 UL WHT BLK RED MR3 UL AUX PGM PGM OUTPUT RELAY YEL BRN COM N C...