ESPRIT 748ES
WIRING DIAGRAM
BLACK
RED
Caution:
Disconnect battery before replacing fuse.
BRN
GRY
GRN
RED
"TLM" LED
Short flash = OK
Long flash = Fault
OFF
= Disabled
Constant = On Line
COM
COM
Z1
Z2
Z3
Z4
Z5
Z6
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
AC
AUX
AUX
AUX
AUX
AUX
BELL
PG1 PG2
N.C.
N.0.
BATT
GRN YEL
+
AC
AC
BATT
5 AMP
DIALER
Warning:
Disconnect telephone
line before servicing.
xxx-xx
xxx
Zone
13 or 14
KEYSWITCH CONNECTION
KEYSWITCH
KYPD GRN
KYPD BLK
220
W
N.C.
N.O.
1K
EOL
W
*
Zone 13
Zone 14
Keypad software versions prior to
4.0
Keypad supervision must be
OFF
}
Keypad software versions
onward
4.0
Keypad supervision must be
ON
}
*
(See Address
, key
)
090
[11] [12]
FIRE RESET
To program PGM1 to conduct 4 second smoke detector reset when
and
are pressed simultaneously:
[
]
[
]
CLEAR
ENTER
Address
=
(first digit)
Address
=
039
[
]
040
[5] [10]
BYP
Address
=
Address
=
042
[2 ] [6]
056
[10] [10] [4]
ND
For resistor values,
refer to 639
installation manuals.
Keyswitch can be used in
parallel with keypad (Not on
UL systems).
GROUND START CIRCUIT
RNG
WHT
BLK
RED
YEL
MR3-UL
+AUX
PGM
FIRE ALARM ZONE CONNECTIONS
*
PGM maximum 50mA
Smoke detector
power supervision
relay, 12VDC
COM
Smoke
detector
Smoke
detector
PGM
Z3
AUX
+
1K
EOL
W
Smoke detector must be 4 wire latching -
UL Falcon model 5454, ULC BRK 2412.
Power supervision relay model MR3-UL.
*
WHT
BLK
RED
MR3-UL
+AUX
PGM
PGM OUTPUT RELAY
YEL
BRN
COM
N.C. N.O.
780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (450) 491-2313 http://www.paradox.ca
Paradox Security Systems Graphic Dept
PRINTED IN CANADA - 09/01
To metallic enclosure
and grounding rod
TRANSFO
A.C.
POWER
16VAC 75VA
UL: K12 Model T16 V75
ULC: Frost Model FTC 7516Q
Warning:
Improper connection may
result in damage to the system.
BELL OUTPUT 1A max.
UL/ULC: 650mA max.24 hr. stanby. Bell output
will shut down if current exceeds 3A.
Smoke and heat detectors
EOL
RES
N.O. contacts
*
Zone 3 = Fire zone if zone
definition is "24 hour".
1K
W
GREEN
Can be used as additional
aux. power terminals
AUX POWER 1.2A max.
UL/ULC 225mA max. for 24 hr. standby.
If you have additional wiring to connect to
auxiliary power, you can use the red (+) and
black (-) keypad connectors. Aux. power will
shut down if current exceeds 3A.
BELL
SIREN
Battery charging current
Jumper off: 350mA
Jumper on: 700mA
Charging
and
battery test
LED
(every 60 seconds)
SERIAL
OUTPUT
RESET
JUMPER
DIALER
RELAY
+
UL /ULC: Wheelock 46T-12
KEYPAD
639
MAX 2 per system
KEYPAD
616/636/646
MAX 5 per system
Not permitted on UL listed systems
NOTE:
Keypad zones should
be
programmed as 24hr. zones.
not
**
**