background image

[2    ]

ND

[2    ]

ND

[2    ]

ND

Streamline

section

Data

Description

Address

___/___
___/___

/

___/___

___ ___

Future use
1st digit: value must be entered i.e.
2nd digit: time correction (See table)
1st digit: telephone 1 format
2nd digit: telephone 2 format
1st digit: PGM 1 type
2nd digit: PGM 2 type

[2

]

ND

036
037

038

039

09

PGM 1
PGM 2
PGM mask 1
PGM mask 2

040
041
042
043

___/___
___/___

/

___/___

___ ___

10

TIME CORRECTION:

(address        second digit)

037

[2

]

[1]
[2]
[3]
[4]
[5]
[6]
[7]

ND

- No adjustment
- Plus    4 sec.
- Plus    8 sec.
- Plus  12 sec.
- Plus  16 sec.
- Plus  20 sec.
- Plus  24 sec.
- Plus  28 sec.

[8]
[9]
[10]
[11]
[12]
[

]

[

]

[

]

- Minus    4 sec.
- Minus    8 sec.
- Minus  12 sec.

- Minus  16 sec.
- Minus  20 sec.
- Minus  24 sec.
- Minus  28 sec.

- Minus  32 sec.

BYP

MEM

TRBL

COMMUNICATOR FORMATS

Key

[2

]

[1]
[2]
[3]
[4]
[5]

ND

[6]
[7]
[8]
[9]

[10]

[

]

TRBL

=

slow (1400Hz, 1900Hz, 10bps)

= (1400Hz, 1800Hz, 10bps)
=

fast (1400Hz, 1900Hz, 20bps)

=

(2300Hz, 1800Hz, 20bps)

=                      (40bps with 1400Hz handshake)
=                      (40bps with 2300Hz handshake)

ADEMCO

SILENT KNIGHT
SESCOA
RADIONICS
RADIONICS

=                      with PARITY (1400Hz, 40bps)
=                      with PARITY (2300Hz, 40bps)
=

express

=

contact ID (programmable codes)

=

contact ID (all codes)

=

- no handshake (personal dialing)

RADIONICS
RADIONICS
ADEMCO
ADEMCO
ADEMCO
DTMF

- 3 -

PG748ES

For addresses

to

, see pages 7 to 10.

044

126

CID

100:
110:
111:
112:
113
114:
115:
116:
117:
118:
120:
121:
122:
123:
130:
131:
132:
133:
136:
137:
138:
140:
150:
151:
152:
153:
154:
155:
156:
157:
158:
159:
161:

CID

300:
301:
302
305:
306:
309:
320:
321:
323:
350:
351:
354:
370:
371:
372:
373:
382:
383:
400:
401:
402:
403:
404:
407:
410:
441:
570:
572:
573:
574:
601:
602:
625:

P

ROG. VALUE

[2

] / [1]

[2

] / [2]

[2

] / [3]

[2

] / [4]

[2

] / [5]

[2

] / [6]

[2

] / [7]

[2

] / [8]

[2

] / [9]

[2

] / [10]

[2

] / [11]

[2

] / [12]

[2

] / [

]

[2

] / [

]

[2

] / [

]

[1] / [2

]

[1] / [1]
[1] / [2]
[1] / [3]
[1] / [4]
[1] / [5]
[1] / [6]
[1] / [7]
[1] / [8]
[1] / [9]
[1] / [10]
[1] / [11]
[1] / [12]
[1] / [

]

[1] / [

]

[1] / [

]

[2] / [2

]

[2] / [1]

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

BYP

ND

MEM

ND

TRBL

ND

BYP

MEM

TRBL

ND

P

ROG. VALUE

[2] / [2]
[2] / [3]
[2] / [4]
[2] / [5]
[2] / [6]
[2] / [7]
[2] / [8]
[2] / [9]
[2] / [10]
[2] / [11]
[2] / [12]
[2] [

]

[2] [

]

[2] [

]

[3] / [2

]

[3] / [1]
[3] / [2]
[3] / [3]
[3] / [4]
[3] / [5]
[3] / [6]
[3] / [7]
[3] / [8]
[3] / [9]
[3] / [10]
[3] / [11]
[3] / [12]
[3] [

]

[3] [

]

[3] [

]

[4] / [2

]

[4] / [1]
[4] / [2]

/
/
/

/
/
/

BYP

MEM

TRBL

ND

BYP

MEM

TRBL

ND

R

EPORTING CODE

AUXILIARY ALARM
FIRE ALARM
FIRE SMOKE
COMBUSTION
WATER FLOW
HEAT
PULLSTATION
DUCT
FLAME
NEAR ALARM
PANIC ALARM
DURESS
SILENT PANIC
AUDIBLE PANIC
BURGLARY
PERIMETER BURG.
INTERIOR BURG.
24HR BURGLARY
BURGLARY OUTDOOR
BURGLARY TAMPER
BURGLARY NEAR ALARM
GENERAL ALARM
24 HOUR AUX
GAS DETECTED
REFRIGERATION
LOSS OF HEAT
WATER LEAKAGE
FOIL BREAK ALARM
DAY TROUBLE ALARM
LOW GAS LEVEL
HIGH TEMPERATURE
LOW TEMPERATURE
LOSS AIR FLOW

R

EPORTING CODE

SYSTEM TROUBLE
AC LOSS
LOW SYSTEM BATTERY
SYSTEM RESET
PROGRAM CHANGED
BATTERY TEST FAIL
SOUNDER/RELAY TROUBLE
BELL 1 TROUBLE
ALARM RELAY TROUBLE
COMMUNICATION TROUBLE
TELCO 1 FAULT
FAIL TO COMMUNICATE
PROTECTION LOOP TROUBLE
PROTECTION LOOP OPEN
PROTECTION LOOP SHORT
FIRE LOOP TROUBLE
SENSOR TROUBLE
SENSOR TAMPER
OPEN/CLOSE
OPEN/CLOSE BY USER #
GROUP OPEN/CLOSE
AUTOMATIC OPENING/CLOSING
LATE TO OPEN/CLOSE
REMOTE ARM DOWNLOAD
REMOTE ACCESS
OPEN/CLOSE - STAY MODE
BYPASS
24 HOUR ZONE BYPASS
BURGLARY BYPASS #
GROUP BYPASS
MANUAL TEST
PERIODIC TEST
TIME/DATE RESET

PROGRAMMABLE CONTACT ID EVENT CODES

All addresses from

to

(sections

to

) programmed with values other than

will report the contact

ID codes corresponding to the values programmed. Values to be programmed should be selected from this table.

300

527

11

67

[2    ] [2    ]

ND

ND

Содержание Esprit 748ES

Страница 1: ...ON PROGRAMMING Can be used to program sections 00 to 67 addresses 000 to 043 and 300 to 527 Press ENTER installer code and 7 2ND and ENTER keys alternately flash Enter a 2 digit section number followe...

Страница 2: ...RAL STATION TELEPHONE NUMBER 2 View at addresses 024 to 031 06 __ __ __ __ __ __ __ __ 07 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ACCOUNT A AND B View at addresses 032 to 035 08...

Страница 3: ...2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 2 2 1 2 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 1 1 2 2 2 1 ND ND ND ND ND ND ND ND ND ND ND ND ND BYP ND MEM ND TRBL ND BYP MEM TRBL ND P...

Страница 4: ...6 304 305 306 307 ___ ___ ___ ___ _ ___ ___ ___ __ User code 27 User code 28 User code 29 User code 30 328 329 330 331 12 18 User code 7 User code 8 User code 9 User code 10 User code 15 User code 16...

Страница 5: ...9 User code 20 360 361 362 363 368 369 370 371 26 28 User code 33 User code 34 User code 35 User code 36 User code 41 User code 42 User code 43 User code 44 User code 45 User code 46 User code 47 User...

Страница 6: ...__ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 44 50 46 52 Zone 21 Zone 22 Zone 23 Zone 24 Zone 21 Zone 22 Zone 23 Zone 24 444 445 446 447 468 469 470 471 ___ _...

Страница 7: ...value will be displayed on keypad 4 Enter 3 digit DECIMAL value 5 Repeat from step 2 onward for next address To exit programming mode press CLEAR 044 ___ ___ ___ hours Auto arm time between 000 and 0...

Страница 8: ...conds and 129 to 255 for minutes factory default 5 seconds Add 128 to desired value in minutes i e for 5 minutes enter 5 128 133 057 ___ ___ ___ Intellizone delay in seconds minimum 10 seconds factory...

Страница 9: ...s 4 6 keys 7 9 Address 086 Key 2 1 ND REPORTING OPTIONS Regular reporting Reporting disabled Split reporting Alarms System report Double reporting 1 2 1 2 1 2 1 2 fail to comm 1 1 1 1 1 1 1 1 fail to...

Страница 10: ...nter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes MEM Panel time and clear trouble 8 all 3 codes Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes BYP Te...

Страница 11: ...ff reset key 11 off reset N C and or N O contacts see Figure 2 ZONE connection without EOL resistor with tamper recognition N C contacts address 088 key MEM on key 10 key 11 Tamper transmits separate...

Страница 12: ...detector PGM Z3 AUX 1K EOL W Smoke detector must be 4 wire latching UL Falcon model 5454 ULC BRK 2412 Power supervision relay model MR3 UL WHT BLK RED MR3 UL AUX PGM PGM OUTPUT RELAY YEL BRN COM N C...