background image

2

Step 2: To program features

Press [ENTER] [2828] or [282828] , you are in the programming mode, ENTER key is flashing

[key in 088], [ON key 1,2,3,4,5,6,7,8, 9 &12] & [OFF key MEM]
[key in 090], [ON key 11 or/and 12], for keypad zone

[key in 049], [enter 060], for exit delay 60 seconds
[key in 050], [enter 060], for entry delay 60 seconds
[key in 053], [enter 003], for zone speed 45 ms. (for vibration sensor). 004 for 60 ms, 005 for 75 ms.

* Choose either Step 3A or 3B

Step 3A: To call CMS

Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing

[key in 038][press 10 then 10], contact ID format
[key in 086][ON key 7 & 12][ENTER][CLEAR], to call CMS phone.
[key in 090][ON key 10][ENTER][CLEAR], to enable Duress signal.

[key in 046][enter 001], for daily test
[key in 047][enter HHH], for hour
[key in 048][enter HHH], for minutes

Press [ENTER] [2828] or [282828] ,then [7], you are in the streamline programming mode, ENTER key
and 2ND are flashing.

[key in 04][enter phone number 1][ENTER][CLEAR], CMS phone number 1
[key in 06][enter phone number 2][ENTER][CLEAR], CMS phone number 2
[key in 08][enter 8888 8888][ENTER][CLEAR], account number

Note: to clear phone number, replace digit with [2ND]

Step 3B: To call Handphone

Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing

[

key in 037][enter 7 then 2ND], waits for 15 rings call duration

[key in 038][enter TRBL then TRBL], pager format
[key in 086][ON key 7, 11 & 12][ENTER][CLEAR],

to call phone 1 and phone 2 each ONE time

Note: if only [ON key 7 & 12, OFF key 11][ENTER][CLEAR], to call ONLY phone 1 one time

[key in 090][ON key MEM],

Press [ENTER] [2828] or [282828] ,then [7], you are in the streamline programming mode, ENTER key
and 2ND are flashing.

[key in 36][enter 33333333], to report zone 1 to 4
[key in 37][enter 33333333], to report zone 5 to 8 (program only if these zones are used)
[key in 38][enter 3333], to report zone 9 to 10

[key in 64][enter 2ND 2ND 333333][ENTER][CLEAR], to report panics

[key in 04][enter phone number 1][ENTER][CLEAR], handphone number 1
[key in 06][enter phone number 2][ENTER][CLEAR], handphone number 2
[key in 08][enter 8888 8888], account number

Содержание ESPRIT 728 ULT

Страница 1: ...es that are not selected in 100 to 108 automatically become delay zone key in 096 ON key wants to be SILENT zone key in 116 ON key wants to be STAY zone key in 124 ON all zone to allow for bypass Exam...

Страница 2: ...number 1 ENTER CLEAR CMS phone number 1 key in 06 enter phone number 2 ENTER CLEAR CMS phone number 2 key in 08 enter 8888 8888 ENTER CLEAR account number Note to clear phone number replace digit wit...

Страница 3: ...ch Connect a 500 ohm resistor in series with AUX of keypad black wire another wire connect to GRN of keypad green wire 500 ohm resistor 3 Partitioning key in 086 ON key 8 ENTER CLEAR to enable partiti...

Страница 4: ...setting in address 053 should be 004 and above to avoid false alarm caused by vibration sensors For Fire zone connections using 4 wire smoke detector Once zone 3 is enable as FIRE zone in this zone d...

Страница 5: ...r 3 seconds For Fire zone connections using 2 wire smoke detector Z1 Z2 Z3 Z4 Note Maximum up to 5 pcs 2 wire smoke detector 1 K 2 2 K 1 C 2 3 C 2 wire Smoke detector NO PGM AUX AUX 1 K 2 2 K 1 K 2 2...

Страница 6: ...in the programming mode ENTER key is flashing Press ENTER 2828 8 CLEAR to activate walk test mode Press ENTER 2828 8 CLEAR to de activate walk test mode To reset panel back to factory default 1 Remove...

Страница 7: ...0 10 button for 3 seconds One touch STAY arming Press hold the key 11 STAY button for 3 seconds One touch INSTANT arming Press hold the key 11 STAY button for 3 seconds then again Press hold again th...

Страница 8: ...me for zone Press hold any button from 1 to 6 for 3 seconds Button 1 for zone 1 button 2 for zone 2 To activate deactivate chime for keypad zone Press hold button 8 To activate deactivate Buzzer Mute...