background image

should be programmed. The installer code has access to all fea-

tures programming but can't use any system functions

(arming/disarming, bypassing, master and user codes program-

ming). The factory-set installer code can be modified by following

the instructions outlined in "Changing the installer code". If the

new code is forgotten, the factory default code can be reset,

unless the "installer code lock" has been enabled.

When entering information on the keypad, pressing 

[

CLEAR

]

eras-

es the last keypad entries and returns panel to its previous status.

If no key is pressed within 2 minutes, the unit automatically clears

its memory and returns to normal status. Pressing 

[

ENTER

]

accepts keyed-in data into memory.

For all keypad/programming operations, key 

[10]

represents the

digit "

0

".

Installer code programming:

To activate the programming mode for the first time, the factory

default installer code must be entered on the keypad. To do so,

press 

[

ENTER

]

, followed by the 4-digit default installer code 

0000

. The

"

ENTRY

" beep will sound and the 

[

ENTER

]

light will 

flash

to indicate

that the system is in programming mode, waiting for address entry.

Changing the installer code: (address 00, 01, 02)

The system default installer code contains four digits. (Based on

your customers' requirements. It can also be modified to contain

six digits.) While in programming mode, a new installer code can

be created using the installer code memory address 

00

01

and

02

. If the four digit default code length is to be used, "00" is the

memory address corresponding to the 1st 2 digits of the new

installer code and address 

01

corresponds to the last two digits.

The digits 

[0][0] 

(

[10][10]

) can be then entered in the third memo-

ry address 

02

so that code reset will not be necessary if the panel

code length is switched back to 6 digits.

Example: To change the system installer code 0000 to 9876:

Enter programming mode. Press 

[

ENTER

]

+

[0][0] [0][0]

. "

CONFIRMATION

"

beep sounds and 

[

ENTER

]

key flashes, indicating that the panel is in

"

ENTER ADDRESS

" mode. Press 

[0] + [0]

(address for 1st 2 digits of

new installer code). "

CONF

" beep will sound. 

[

ENTER

]

will light up and

remain on, indicating  that the system is in "

ENTER DATA

" mode.

Key in the first 2 digits of your new code. In this example: 

[9]

[8]

[

ENTER

]

. "

CONF

" beep is heard. The system returns to "

ENTER

ADDRESS

" mode, and the 

[

ENTER

]

key flashes.

Press 

[0]

[1]

(address for last pair of digits of the new installer

code). "

CONF

" beep follows, and the system is back in "

ENTER

DATA

" mode. Key in the 3rd + 4th digits of your new code. In this

example: 

[7]

[6]

[

ENTER

]

. "

CONF

" beep sounds.

Press 

[0]

[2]

(address for mandatory pair of digits of the new

installer code). "

CONF

" beep follows, and the system is back in

"

ENTER DATA

" mode.

Key in 

[0][0]

[

ENTER

]

. "

CONF

" beep sounds.

The installer code 9876 has been entered into memory. The sys-

tem remains in programming mode, with the 

[

ENTER

]

key flashing.

(If a six digit installer code is required, same steps are followed, but

the mandatory 00 digits are replaced by the third pair of digits of

the six digit code.) More programming data can now be entered or

programming mode can be exited by pressing 

[

CLEAR

]

. After exiting

programming mode, the "

END

/

REJECTION

" beep will sound.

Restoring the factory default installer code:

If a new installer code is lost or forgotten, the control panel can be

returned to the factory-set default code by following these steps:

(1) Remove AC and battery to power down the unit.

(2) Connect a jumper between the EEPROM reset pins.

(3) Connect AC or battery.

(4) Wait for 5 seconds, then remove jumper.

The default installer code has now been restored. All other pro-

grammed data remains the same. If an installer wishes to disable

the factory default "reset" feature, this can be done by activating

the "installer code lock".

"

Installer code lock

"

: (address 37)

The memory address for this feature is 

37

. In program mode,

when address 

37

is entered, the status of the "installer code lock"

will be displayed on key 

[1]

. The "installer code lock" function can

be modified by selecting this key.

Key 

[1]

on: System returns to default installer code upon reset

Key 

[1]

off: Installer code 

locked

. (will not revert to system

default upon reset) 

Important

: if the installer code

lock is activated, and the new installer code is subse-

quently lost or forgotten, there is no way to return the

system to programming mode. The panel must be

returned to Paradox Security Systems for installer

code reset. There is a charge for this service.

Code Priority:

There are several different types of system access codes and

each has been assigned a priority which determines which sys-

tem functions and features it can activate. The Installer Code

(Priority 1)

can be use to program all system features but has no

access to arming/disarming and access code programming. (This

is the only code that can access installer code programming.) The

Master User Code 

(priority 2)

can arm/disarm the system (using

all arming options), activate zone bypassing and reprogram mas-

ter and user codes. User Codes 1-3 

(priority 3)

can be used to

arm/disarm the system, activate "stay" and "away" arming, and

zone bypassing. User Codes 4-6 

(priority 4)

can arm/disarm the

system. User Code 7 

(priority 5)

is an "Arm only" access code.

Master and User Code programming:

To program the master and all user codes:

Press 

[

ENTER

]

+ master code + 1 digit access code new

4 or 6 digit code + 

[

ENTER

]

.

Note

: If only 2 or 4 digits are entered, digits "00" will be automati-

cally enter in the remaining memory space.

Master code:

[1]

Arm, disarm, bypass, away, stay, reprogram mas-

ter and user codes (

default/reset code 010101)

User code 1:

[2]

Arm, disarm, bypass, away, stay

User code 2:

[3]

Arm, disarm, bypass, away, stay

User code 3:

[4]

Arm, disarm, bypass, away, stay

User code 4:

[5]

Arm, disarm

User code 5:

[6]

Arm, disarm

User code 6:

[7]

Arm, disarm

User code 7:

[8]

Arm only

"

ARM ONLY

"

CODE:

Can only be used to arm the system. No

other system features can be accessed, and the system cannot

be disarmed using the "Arm Only" code, unless it is used during

the exit delay period.

Deleting a user code: 

Pressing the 

[2

ND

]

key, followed by

[

ENTER

]

while in any user code address, will delete that user code.

Exit delay/entry delay/alarm duration programming:

The memory addresses for exit and entry delay, and alarm dura-

tion are:

"

27

" exit (00-99seconds)

"

28

" entry (00-99 seconds)

"

29

" alarm (00-99 minutes)

PROGRAMMABLE OUTPUTS: (address 30)

The memory address for programmable output options is 

30

. The

next two digits entered assign the conditions which cause PGM

output to ground. The first digit entered corresponds to PGM 1,

and the second digit to PGM 2.

2