ATTACHMENT LIMITATION NOTICE

ESPRIT

708/ 718/728L/ 728/738/ 748/ 748ES

The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain
telecommunications network protective, operational and safety requirements. The Department does not guarantee
the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. The
customer should be aware that compliance with the above conditions may not prevent degradation of service in
some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the
supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone
lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly
important in rural areas.

CAUTION

Users should not attempt to make such connections themselves, but should contact the appropriate electri-

cal inspection authority, or electrician, as appropriate.

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to
a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any
combination of devices subject only to the requirement that the total of the Load Numbers of all of the devices does
not exceed 100. The Load Number of this unit is 7.

Industry Canada certification is only applicable to installation of devices which include transformers approved by the
Canadian Standards Association (CSA).

RESTRICTIONS CONCERNANT LE RACCORDEMENT DE MATÉRIEL

L'étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à
certaines normes de protection, d'exploitation et de sécurité des réseaux de télécommunications. Le Ministère n'as-
sure toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.

Avant d'installer ce matériel, l'utilisateur doit s'assuré qu'il est permis de le raccorder aux installations de l'entreprise
locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de raccorde-
ment. L'abonné ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus n'em-
pêchent pas la dégradation du service dans certaines situations. 

Les réparations de matériel homologué doivent être effectuées par un centre d'entretien canadien autorisé désigné
par le fournisseur. La compagnie de télécommunications peut demander à l'utilisateur de débrancher un appareil à la
suite de réparations ou de modifications effectués par l'utilisateur ou à cause d’un mauvais fonctionnement.

Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'energie élec-
trique, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette
précaution est particulièrement importante dans les régions rurales.

AVERTISSEMENT

L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoit recours à une ser-

vice d'inspection des installations électriques, ou à un électricien, selon le cas.

"L'indice de charge (IC) assigné à chaque dispositif indique, pour éviter toute surcharge, le pourcentage de la charge
totale qui peut être raccordée à un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit
bouclé peut être constituée de n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de
charge de l'ensemble des dispositifs ne dépasse pas 100." L'indice de charge de ce produit est 7.

La certification d'Industrie Canada s'applique seulement aux installations d'appareils utilisant un transformateur
approuvé par l'Association Canadienne de Normalisation (CSA).

35

IM8

Содержание Esprit 718

Страница 1: ...Installation Manual P R D O X P R D O X S E C U R I T Y S Y S T E M S S E C U R I T Y S Y S T E M S ESPRIT 718 728L 728 738 748 748ES 718 728L 728 738 748 748ES IM8 960715 0000...

Страница 2: ...ended application 2 If the installation is a FIRE ALARM application refer to NFPA Standard 74 for details on locating smoke detectors There must be at least one UL Listed Indoor Fire Alarm Warning Sig...

Страница 3: ...K UP 9 BATTERY TEST 9 ZONE WIRING CONFIGURATIONS AND OPTIONS 9 12 LOOP CONFIGURATIONS AND ZONE CONNECTION 9 ATZ Zone Identification Table 9a Resistor Guides 9a Advanced Technology Zoning 10 11 Single...

Страница 4: ...ERS 22 PC download telephone number 22 Central station telephone numbers 22 System account codes 22 REPORTING CODES 23 24 General 23 Arming codes disarming codes 23 Zone alarm codes 23 Zone restoratio...

Страница 5: ...on Tamper wire Fault 30 No tamper bypass 30 Only bypass code reported on bypass arming 30 Advanced Technology Zoning ATZ 30 Audible Trouble Warning 30 Keypad zone supervision 30 31 ZONE DEFINITION 31...

Страница 6: ...phone line monitor and fast formats Model 718 does not provide fast formats Esprit 718 UL ULC listed Up to 5 hardwire zone control panel Comprised of 3 onboard single zone inputs up to 2 additional ke...

Страница 7: ...er on a single pair of wires as well as wire fault recognition ATZ simplifies the task of meeting the zone requirements of any application and at the same time reduces installation costs 5 Advanced Te...

Страница 8: ...nd or report only Programmable Outputs Almost any control panel status situation may be used to activate the Esprit s programmable outputs Once a panel status mode is selected for a PGM to follow the...

Страница 9: ...ttery Charger 360mA with active Battery test Aux power 400 mA UL ULC installations Fuseless electronic shut down at 1A Automatic restore Bell Out 1A Fuseless electronic shut down at 3A Automatic resto...

Страница 10: ...al is the connection for the positive lead Bell terminal is the connection for the neg ative lead The bell output supplies 12V upon alarm It can support two 20 watt or two 30 watt sirens Above 1A batt...

Страница 11: ...blocked if the battery test fails if programmed Test failure causes trouble indicator key 1 to illuminate indicating that battery capacity is insufficient When the panel runs on battery power with or...

Страница 12: ...mper signals SINGLE ZONE connection without EOL resistor N C contacts address 208 key MEM on key 10 off default key 11 off default address 210 key 8 off N C contacts see Figure 1 Note Keypad zones alw...

Страница 13: ...ition wire fault short circuit recognition N C contacts address 208 key MEM off key 10 key 11 address 210 key 8 on Tamper fault transmits separate code Each zone transmits separate alarm code Wire fau...

Страница 14: ...our the tamper definition follows the audible silent alarm arm definition of the 24 hour zone Tamper recognition addresses Tamper report and restoration codes should be programmed at addresses 191 and...

Страница 15: ...unting Dead Air Space The smoke from a fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the ceiling The corner where the ceiling and wall meet is...

Страница 16: ...ature The AWAY key should be pressed followed by a valid access code address 202 The ready light does not have to be on but all open zones must be bypass enabled addresses 236 and 238 Once the exit de...

Страница 17: ...allotted entry time expires If the access code is entered incorrectly press CLEAR and re enter it The armed light will extinguish and the sounder will change to the CONF beep series of short beeps be...

Страница 18: ...that can bypass zones When a code is activated at both addresses 200 and 202 it can do the following 1 The code can fully arm the system If the code is entered when systems A and B are disarmed it wi...

Страница 19: ...nes have been bypassed To cancel the zone bypass status just entered press BYP user code CLEAR Zone bypasses are automatically cancelled every time the system is disarmed except in 24 hour zones If a...

Страница 20: ...ve power failure from trouble display 2ND key should be on at address 210 Key 3 AC power failure software versions prior to 1 4 Inadequate AC power is going to panel Report can also be sent to central...

Страница 21: ...key listed below corresponding to the feature you wish to enable KEY 9 Program auto arming time accessible to Master and User 1 only Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes...

Страница 22: ...ECIAL TIMING FUNCTIONS The time programmed at addresses 245 246 can be used to 1 Auto arm the system and if programmed transmit the arming code at address 188 SECTION 32 2 Specify the time of day for...

Страница 23: ...nel will not answer Default value is 2ND 8 UPLOAD PANEL IDENTIFIER Addresses 001 002 DIRECT ADDRESS This four digit code identifies the control panel to the PC before uploading can be initiated Each p...

Страница 24: ...uffer is full and call PC feature is enabled 208 2ND on this number will be dialed in order to download the event list Related features Upload Panel ID 001 002 PC password 003 004 Central Station Tele...

Страница 25: ...ming the control panel to the central monitoring station Each user code can be assigned an arm disarm report code Espload and the master code can be assigned a report code at addresses 188 189 see spe...

Страница 26: ...Espload Using Espload to disarm the system will generate a special report code Disarm with master code Using the master code to disarm the system will generate a special report code Two digit hexa cod...

Страница 27: ...t at 514 491 2313 SYSTEM OPTIONS Default off for addresses 200 242 Code priority Addresses 200 to 204 Key 1 represents user code 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 BYP 13 MEM 14 TRBL...

Страница 28: ...ay be programmed to arm at the same time every day Program both the hour and minute addresses 245 246 for arming This will also be the auto test report time if enabled A late closing code may be progr...

Страница 29: ...on reporting or disarm On split reporting silent zones panic are reported to Telephone 1 The Contact ID report for all zones is burglary Dialing pulse rates for Espload Address 206 key 10 This selecti...

Страница 30: ...y key 7 Double reporting dialing procedure 2 2 2 2 2 2 2 2 communicator report failure 1 1 1 1 1 1 1 1 communicator report failure Note To stop communication attempts until the next reportable event p...

Страница 31: ...stay arm system for 2 seconds User access code length Address 208 Key 9 off 6 digit user access codes and installer code Key 9 on 4 digit user access codes and installer code Tamper wire Fault Defini...

Страница 32: ...ilure Low Voltage is present Arm inhibit on Tamper wire Fault Address 210 key 5 Key on system will not arm if Tamper fault is present MUST BE RESET BY INSTALLER BEFORE SYSTEM CAN BE ARMED AGAIN No tam...

Страница 33: ...armed Zone 3 becomes a fire zone when defined 24 hour Zone 12 for software versions prior to 0 98 The fire zone should always be connected with a green 1K OHM EOL resistor If there is a line short in...

Страница 34: ...m the system on time if enabled at address 206 key 5 3 Send a late to close code programmed at address 190 If the system is not armed at this time and if address 253 no movement time is disabled by pr...

Страница 35: ...l reset without powering down the installer code is required Panel reset without power down 1 Connect a jumper between reset jumper pins 2 Press ENTER installer code STAY 3 Remove jumper The factory d...

Страница 36: ...cations to maintain uninterrupted service GENERAL This equipment shall not be used on coin telephone lines Connection to party line service is subject to state tariffs RINGER EQUIVALENCE NUMBER REN Th...

Страница 37: ...CTIONS CONCERNANT LE RACCORDEMENT DE MAT RIEL L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme certaines normes de protection d exploit...

Страница 38: ...configurations and zone connection 9 Master and user codes 19 No movement report 20 No tamper bypass 30 One Key arming enable 29 One key user programming commands 19 Only bypass code reported on bypas...

Отзывы: