Keypad 1 zone supervision
(Address 210, key [11])
Keypad 2 zone supervision
(Address 210, key [12])
(“on” = enabled)
(“off” = disabled)
When activating zone supervision for only one keypad, by turning “on” either key [11] or [12], the other
keypad zone supervision “activation” key must be disabled. (Ex.: if key [11] is “on”, key [12] must be “off”.)
When connecting more than two keypads on one system, all keypads that are not using a keypad zone
must have their keypad zone terminal shorted.
***Keypad zone supervision should be used only on keypads with software versions 4.0
onward and/or the Esprit 640 LCD keypad, with keypad zone supervision enabled
(Address 32, key [3] “on”.
ZONE DEFINITION
(Addresses 212-242)
Zone definition is assigned during "feature selection" programming. Turning zone key "on" or "off" at
addresses 212-242 assigns a particular definition to the zone. (See Programming Work Sheets.)
Slow/fast
(Addresses 212, 214)
"Open" zone status of a slow zone (keys "off") and alarm will only be communicated after a programmed time
period between 15 and 4000 milliseconds has elapsed. (Slow response time programmed at address 251.)
Fast zones (keys "on") provide detection after 20 milliseconds if a zone is opened.
Silent/audible
(Addresses 216, 218)
Silent zones (keys "on") report alarms without triggering bells/sirens.
Audible zones (keys "off ") will trigger a bell or siren upon alarm generation.
24 hour - fire/regular
(Addresses 220, 222)
"24 hour" zones (keys "on") generate alarms whenever the zone is open, even if the system is not armed.
Zone 3 becomes a fire zone when defined "24 hour". (Zone 12 for software versions prior to 0.98). The
fire zone should always be connected with a green (1K
OHM
) EOL resistor. If there is a line short in the
fire zone, a fire alarm will be generated. If the line is "open", a fire trouble report (if assigned at address
182) will be sent to the central, and trouble indicator [11] and fire zone key [3] illuminate on the key-
pad. (Key [12] for software versions prior to 0.98). Alarms in a fire zone generate an intermittent out-
put signal, regardless of system arming status. ("24 hour/fire" zone definition takes priority over
"instant", "follow", "stay", Delay 1 and Delay 2 definition.)
Instant
(Addresses 224, 226)
"Instant" zones (keys "on") will immediately generate an alarm when opened while the system is armed.
There is no entry delay.
Follow
(Addresses 228, 230)
"Follow" zones (key "on") are "instant" zones that switch to "delay" definition during entry delay.
Delay 2
(Addresses 232, 234)
One of two different zone delays (delay 1 and delay 2) can be assigned to each zone. Zones activated at
these addresses are assigned "Delay 2" definition. The length of zone entry delays is programmed at
addresses 248-249. Any zones that are not activated at addresses 220-234 are assigned "Delay 1" zone
definition.
Note:
When more than one zone definition is selected, zone definition priority will be assigned
in this order (1) 24 hr., (2) instant, (3) follow, (4) delay 2 and (5) delay 1.
31
IM8
Note: Addresses 214, 218, 222, 226, 230, 234, 238 define zones 13-24, which are not available
on the 718, 728L and 728.
On the 738, only zones 13 and 19 are used.
Default definition of all zones is "Delay 1", unless otherwise programmed at addresses 220-234.