background image

FCC WARNINGS

ESPRIT

708/ 718/728L/ 728/738/ 748/ 748ES

IMPORTANT INFORMATION

This equipment complies with Part 68 of the FCC rules. Inside the cover of this equipment is a label that contains,
among other information, the FCC registration number of this equipment.

NOTIFICATION TO TELEPHONE COMPANY

Upon request, customer shall notify telephone company of particular line to which the connection will be made, and
provide the FCC registration number and the ringer equivalence of the protective circuit.

FCC 

REGISTRATION NUMBER

:

5A7CAN-22633 - AL - E

RINGER EQUIVALENCE NUMBER

:

0.0B

USOC 

JACK

:

RJ31X (USA), CA31A (CANADA)

TELEPHONE CONNECTION REQUIREMENTS

Except for telephone company-provided ringers, all connections to the telephone network shall be made through standard plugs
and telephone company-provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal
equipment. Standard jacks shall be so arranged that, if plug connected thereto is withdrawn, no interference to operation of
equipment at customer's premises which remains connected to telephone network shall occur by reason of such withdrawal.

INCIDENCE OF HARM

Should terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where
practicable, notify customer that temporary disconnection of service may be required; however, where prior notice is
not practicable, the telephone company may temporarily discontinue service if action is deemed reasonable in cir-
cumstances. In case of temporary discontinuance, telephone company shall promptly notify customer and will be
given opportunity to correct the situation.

CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES

The telephone company may make changes in its communication facilities, equipment operations or procedures,
where such actions are reasonably required and proper in its business. Should any such changes render customer's
terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice
to effect the modifications to maintain uninterrupted service.

GENERAL

This equipment shall not be used on coin telephone lines. Connection to party line service is subject to state tariffs.

RINGER EQUIVALENCE NUMBER

(

REN

)

The 

REN

is useful to determine the quantity of devices that you may connect to your telephone line and still have all of

those devices ring when your telephone number is called. In most, but not all areas, sum of the 

REN

's of all devices

connected to one line should not exceed five (5.0). To be certain of the number of devices that you may connect to
your line, you may want to contact your local telephone company.

EQUIPMENT MAINTENANCE FACILITY

If you experience trouble with this telephone equipment, please contact facility indicated below for information on
obtaining service or repairs. The telephone company may ask that you disconnect this equipment from network until
problem is corrected or until you are sure that the equipment is not malfunctioning.

U

.

S

POINT OF CONTACT

:

Paradox U.S.
1717 Minnesota Avenue
Winter Park, Florida
32789 USA  1-800-786-9321

FCC PART

15, 

WARNINGS

INFORMATION TO USER

This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to equipment intermittently, the user is encouraged to try to correct the interference by
one or more of the following measures: (1) reorient or relocate the receiving antenna; (2) increase the separation
between the equipment and receiver; (3) connect the equipment to an outlet on a circuit other than the one to which
the receiver is connected, or (4) consult the dealer or an experienced radio/tv technician for assistance.

CAUTION

Changes or modifications not expressly approved by 

PARADOX SECURITY SYSTEMS 

could void the user's authority

to operate the equipment.

34

IM8

Содержание Esprit 718

Страница 1: ...Installation Manual P R D O X P R D O X S E C U R I T Y S Y S T E M S S E C U R I T Y S Y S T E M S ESPRIT 718 728L 728 738 748 748ES 718 728L 728 738 748 748ES IM8 960715 0000...

Страница 2: ...ended application 2 If the installation is a FIRE ALARM application refer to NFPA Standard 74 for details on locating smoke detectors There must be at least one UL Listed Indoor Fire Alarm Warning Sig...

Страница 3: ...K UP 9 BATTERY TEST 9 ZONE WIRING CONFIGURATIONS AND OPTIONS 9 12 LOOP CONFIGURATIONS AND ZONE CONNECTION 9 ATZ Zone Identification Table 9a Resistor Guides 9a Advanced Technology Zoning 10 11 Single...

Страница 4: ...ERS 22 PC download telephone number 22 Central station telephone numbers 22 System account codes 22 REPORTING CODES 23 24 General 23 Arming codes disarming codes 23 Zone alarm codes 23 Zone restoratio...

Страница 5: ...on Tamper wire Fault 30 No tamper bypass 30 Only bypass code reported on bypass arming 30 Advanced Technology Zoning ATZ 30 Audible Trouble Warning 30 Keypad zone supervision 30 31 ZONE DEFINITION 31...

Страница 6: ...phone line monitor and fast formats Model 718 does not provide fast formats Esprit 718 UL ULC listed Up to 5 hardwire zone control panel Comprised of 3 onboard single zone inputs up to 2 additional ke...

Страница 7: ...er on a single pair of wires as well as wire fault recognition ATZ simplifies the task of meeting the zone requirements of any application and at the same time reduces installation costs 5 Advanced Te...

Страница 8: ...nd or report only Programmable Outputs Almost any control panel status situation may be used to activate the Esprit s programmable outputs Once a panel status mode is selected for a PGM to follow the...

Страница 9: ...ttery Charger 360mA with active Battery test Aux power 400 mA UL ULC installations Fuseless electronic shut down at 1A Automatic restore Bell Out 1A Fuseless electronic shut down at 3A Automatic resto...

Страница 10: ...al is the connection for the positive lead Bell terminal is the connection for the neg ative lead The bell output supplies 12V upon alarm It can support two 20 watt or two 30 watt sirens Above 1A batt...

Страница 11: ...blocked if the battery test fails if programmed Test failure causes trouble indicator key 1 to illuminate indicating that battery capacity is insufficient When the panel runs on battery power with or...

Страница 12: ...mper signals SINGLE ZONE connection without EOL resistor N C contacts address 208 key MEM on key 10 off default key 11 off default address 210 key 8 off N C contacts see Figure 1 Note Keypad zones alw...

Страница 13: ...ition wire fault short circuit recognition N C contacts address 208 key MEM off key 10 key 11 address 210 key 8 on Tamper fault transmits separate code Each zone transmits separate alarm code Wire fau...

Страница 14: ...our the tamper definition follows the audible silent alarm arm definition of the 24 hour zone Tamper recognition addresses Tamper report and restoration codes should be programmed at addresses 191 and...

Страница 15: ...unting Dead Air Space The smoke from a fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the ceiling The corner where the ceiling and wall meet is...

Страница 16: ...ature The AWAY key should be pressed followed by a valid access code address 202 The ready light does not have to be on but all open zones must be bypass enabled addresses 236 and 238 Once the exit de...

Страница 17: ...allotted entry time expires If the access code is entered incorrectly press CLEAR and re enter it The armed light will extinguish and the sounder will change to the CONF beep series of short beeps be...

Страница 18: ...that can bypass zones When a code is activated at both addresses 200 and 202 it can do the following 1 The code can fully arm the system If the code is entered when systems A and B are disarmed it wi...

Страница 19: ...nes have been bypassed To cancel the zone bypass status just entered press BYP user code CLEAR Zone bypasses are automatically cancelled every time the system is disarmed except in 24 hour zones If a...

Страница 20: ...ve power failure from trouble display 2ND key should be on at address 210 Key 3 AC power failure software versions prior to 1 4 Inadequate AC power is going to panel Report can also be sent to central...

Страница 21: ...key listed below corresponding to the feature you wish to enable KEY 9 Program auto arming time accessible to Master and User 1 only Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes...

Страница 22: ...ECIAL TIMING FUNCTIONS The time programmed at addresses 245 246 can be used to 1 Auto arm the system and if programmed transmit the arming code at address 188 SECTION 32 2 Specify the time of day for...

Страница 23: ...nel will not answer Default value is 2ND 8 UPLOAD PANEL IDENTIFIER Addresses 001 002 DIRECT ADDRESS This four digit code identifies the control panel to the PC before uploading can be initiated Each p...

Страница 24: ...uffer is full and call PC feature is enabled 208 2ND on this number will be dialed in order to download the event list Related features Upload Panel ID 001 002 PC password 003 004 Central Station Tele...

Страница 25: ...ming the control panel to the central monitoring station Each user code can be assigned an arm disarm report code Espload and the master code can be assigned a report code at addresses 188 189 see spe...

Страница 26: ...Espload Using Espload to disarm the system will generate a special report code Disarm with master code Using the master code to disarm the system will generate a special report code Two digit hexa cod...

Страница 27: ...t at 514 491 2313 SYSTEM OPTIONS Default off for addresses 200 242 Code priority Addresses 200 to 204 Key 1 represents user code 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 BYP 13 MEM 14 TRBL...

Страница 28: ...ay be programmed to arm at the same time every day Program both the hour and minute addresses 245 246 for arming This will also be the auto test report time if enabled A late closing code may be progr...

Страница 29: ...on reporting or disarm On split reporting silent zones panic are reported to Telephone 1 The Contact ID report for all zones is burglary Dialing pulse rates for Espload Address 206 key 10 This selecti...

Страница 30: ...y key 7 Double reporting dialing procedure 2 2 2 2 2 2 2 2 communicator report failure 1 1 1 1 1 1 1 1 communicator report failure Note To stop communication attempts until the next reportable event p...

Страница 31: ...stay arm system for 2 seconds User access code length Address 208 Key 9 off 6 digit user access codes and installer code Key 9 on 4 digit user access codes and installer code Tamper wire Fault Defini...

Страница 32: ...ilure Low Voltage is present Arm inhibit on Tamper wire Fault Address 210 key 5 Key on system will not arm if Tamper fault is present MUST BE RESET BY INSTALLER BEFORE SYSTEM CAN BE ARMED AGAIN No tam...

Страница 33: ...armed Zone 3 becomes a fire zone when defined 24 hour Zone 12 for software versions prior to 0 98 The fire zone should always be connected with a green 1K OHM EOL resistor If there is a line short in...

Страница 34: ...m the system on time if enabled at address 206 key 5 3 Send a late to close code programmed at address 190 If the system is not armed at this time and if address 253 no movement time is disabled by pr...

Страница 35: ...l reset without powering down the installer code is required Panel reset without power down 1 Connect a jumper between reset jumper pins 2 Press ENTER installer code STAY 3 Remove jumper The factory d...

Страница 36: ...cations to maintain uninterrupted service GENERAL This equipment shall not be used on coin telephone lines Connection to party line service is subject to state tariffs RINGER EQUIVALENCE NUMBER REN Th...

Страница 37: ...CTIONS CONCERNANT LE RACCORDEMENT DE MAT RIEL L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme certaines normes de protection d exploit...

Страница 38: ...configurations and zone connection 9 Master and user codes 19 No movement report 20 No tamper bypass 30 One Key arming enable 29 One key user programming commands 19 Only bypass code reported on bypas...

Отзывы: