Chapter 1: Introduction
Thank you for purchasing this power protection product. It has been
designed and manufactured to provide many years of trouble-free service.
Please read this manual before installing your EXR UPS Series, models
EXR750RT2U, EXR1000RT2U, EXR1500RT2U, EXR2000RT2U,
EXR3000RT2U, EXR1500RTHV, EXR3000RTHV as it provides important
information that should be followed during the installation and the
maintenance of the UPS system allowing you to correctly set up your system
for the maximum safety and performance. Included is information on
customer support and factory service if it is required. If you experience a
problem with the UPS system, please refer to the Troubleshooting guide in
this manual to correct the problem or collect enough information so that the
Technical Support Department can assist you.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
CONSIGNES DE SÉCURITÉ IMPORTANTES
SAUVEGARDEZ CES CONSIGNES!
Veuillez lire ce manuel avant l'installation de l'onduleur modèles
EXR750RT2U, EXR1000RT2U, EXR1500RT2U, EXR2000RT2U,
EXR3000RT2U, EXR1500RTHV, EXR3000RTHV. Il contient de l'information
importante qui doit être respectée au cours de l'installation et de l'entretien
de l'onduleur et des batteries. Cette information vous permettra de
correctement installer le système pour atteindre son rendement maximum
en toute sécurité.
CAUTION!
The maximum ambient operating temperature for this UPS
series is 40°C (“0 ~ 40°C” for Ambient Operation).
The external vents and openings on the UPS are provided for ventilation.
To ensure reliable operation of the UPS and to protect the UPS from
over-heating, these vents and openings must not be blocked or covered.
Do not insert any object into any of the vents or openings that may
hinder the ventilation.
Install the UPS system in a well-ventilated area, away from excess
moisture, heat, dust, flammable gas, or explosives.
Leave adequate space (at least 20cm) around all sides of the UPS
system for proper ventilation.
Do not mount the UPS system with its front or rear panel facing down at
any angle.
Before usage, you must allow the UPS system to adjust to room
temperature (20°C~25°C or 68°F~77°F) for at least one hour to avoid
moisture condensing inside the UPS.
3
CAUTION!
This UPS series is
ONLY
intended to be installed in an
indoor temperature-controlled environment that is free of conductive
contaminants. This UPS series is not intended for use in a computer room
as defined in the Standard for the Protection of Electronic Computer/Data
Processing Equipment ANSI/NFPA 75.
CAUTION!
Connect the UPS to a two pole, three wire, grounded, utility
power AC wall outlet. The receptacle must be connected to the appropriate
branch protection (circuit breaker or fuse). Connection to any other type of
receptacle may result in a shock hazard and violate local electrical codes.
Do not use extension cords, adapter plugs, or surge strips.
CAUTION!
To reduce the risk of fire, connect only to a utility power
circuit provided with 20 / 30 amperes maximum branch circuit over-current
protection in accordance with the National Electric Code, ANSI/NFPA 70.
CAUTION!
To reduce the risk of electrical shock with the installation of
this UPS equipment and the connected equipment, the user must ensure
that the combined sum of the AC leakage current does not exceed 3.5mA.
CAUTION!
To reduce the risk of electrical shock in conditions where the
load equipment grounding cannot be verified, disconnect the UPS from the
AC wall outlet before installing a computer interface cable. Reconnect the
power cord only after all signaling connections are made.
WARNING:
This Uninterruptible Power Supply contains potentially
hazardous voltages. Do not attempt to disassemble the UPS beyond the
battery replacement procedure. This UPS contains no user serviceable
parts. Repairs and battery replacement must be performed by
QUALIFIED
SERVICE PERSONNEL ONLY.
WARNING:
Qualified Service Personnel ONLY
must perform the
Installation and Servicing of these UPS systems. MINUTEMAN accepts no
liabilities and is not limited to injury to the Service Personnel, or damages to;
the UPS, or the connected equipment caused by the incorrect installation or
servicing of the UPS system.
WARNING:
Risk of Electrical Shock. Hazardous live parts inside these
power supplies are energized from the battery even when the AC input is
disconnected.
CAUTION! DO NOT USE THE MOUNTING BRACKETS TO LIFT THE
UPS.
The mounting brackets are
ONLY
for securing the UPS to the rack.