CAUTION!  

To de-energize the outputs of the UPS: 

1.  If the UPS is on press and release the On/Off/Test button.  

NOTE:

 Turn the 

input circuit breaker (on the rear panel) off for the 208V models. 

2.  Disconnect the UPS from the AC wall outlet. 
3.  To de-energize the UPS completely, disconnect the battery. 

 

ON / OFF / TEST BUTTON:  

Press and release the On/Off/Test 

button during the audible alarm's first beep to turn the UPS On.  
Once the UPS successfully passes the twenty second self-test the 
load will be powered.   

NOTE:

    The input circuit breaker (on the rear 

panel) MUST be in the on position for the 208V models. 
 
Press and release the On/Off/Test button during the audible alarm's 
first beep to turn the UPS Off.    The UPS will continue to charge the 
batteries whenever it is plugged into a wall outlet and there is an 
acceptable AC voltage present. 

 

To perform a ten second battery test:  With the UPS in the AC 
normal mode, press and hold the On/Off/Test button until the audible 
alarm sounds four beeps, and then release.  During the test, the 
UPS will switch to the Battery mode, the On-Battery icon will 
illuminate, and the alarm will sound. 

 

NOTICE:  

This equipment has been tested and found to comply with the limits for a 

Class B computing device in accordance with the specifications in Subpart J of Part 
15 of FCC Rules and the Class B limits for radio noise emissions from digital 
apparatus set out in the Radio Interference of the Canadian Department of 
Communications.  These limits are designed to provide reasonable protection 
against such interference in a residential installation.  This equipment generates and 
uses radio frequency and if not installed and used properly, that is, in strict 
accordance with the manufacturer's instructions, this equipment may cause 
interference to radio and television reception.  If this equipment does cause 
interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one 
or more of the following measures: 

 

Reorient the receiving antenna.   

 

Relocate the computer with respect to the receiver. 

 

Move the computer away from the receiver. 

 

Plug the computer into a different outlet so that the computer and receiver are on 
different branch circuits. 

 

Shielded communications interface cables must be used with this product. 

 

WARNING:  

Changes or modifications to this unit not expressly approved by the 

party responsible for compliance could void the user's authority to operate the 
equipment. 
 

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batteries 

must be connected before putting these UPSs into service.  Refer to Section 3 
"Installation" for connecting the batteries. 
 

 
 
 
 
 
 
 
 

Receiving Inspection

 

After removing your UPS from its carton, it should be inspected for damage 
that may have occurred in shipping.  Immediately notify the carrier and 
place of purchase if any damage is found.  Warranty claims for damage 
caused by the carrier will not be honored.    The packing materials that your 
UPS was shipped in are carefully designed to minimize any shipping 
damage.  In the unlikely case that the UPS needs to be returned to the 
manufacturer, please use the original packing material.  Since the 
manufacturer is not responsible for shipping damage incurred when the 
system is returned, the original packing material is inexpensive insurance.  

PLEASE SAVE THE PACKING MATERIALS!

 

 

Life Support Policy

 

As a general policy, we do not recommend the use of any of our products in 
life support applications where failure or malfunction of the product can be 
reasonably expected to cause failure of the life support device or to 
significantly affect its safety or effectiveness.  We do not recommend the 
use of any of our products in direct patient care.    We will not knowingly sell 
our products for use in such applications unless Para Systems receives, in 
writing, assurances satisfactory to us that (a) the risks of injury or damage 
have been minimized, (b) the customer assumes all such risks, and (c) our 
liability is adequately protected under the circumstances. 
 

© COPYRIGHT 2020 BY PARA SYSTEMS, INC.

 

All Rights Reserved. All rights of this User Manual (“Manual”), including but 
not limited to the content, information, and figures are solely owned and 
reserved by Para Systems, Inc. (“Para Systems”). The Manual can only be 
applied to the operation or the use of this product. Any disposition, 
duplication, dissemination, reproduction, modification, translation, extraction, 
or usage of this Manual in whole or in part is prohibited without the prior 
written permission of Para Systems. Given that Para Systems will 
continuously improve and develop the product, changes may be made to the 
information in this Manual at any time without obligation to notify any person 
of such revision or changes. Para Systems will make all possible efforts to 
secure the accuracy and the integrity of this Manual. Para Systems 
disclaims any kinds or forms of warranty, guarantee, or undertaking, either 
expressly or implicitly, including but not limited to the completeness, 
faultlessness, accuracy, non-infringement, merchantability, or fitness for a 
particular purpose of the Manual. 

Содержание MinuteMan EXR Series

Страница 1: ...Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000537 R2 User s Manual...

Страница 2: ...ls and Indicators 6 3 Installation 11 4 Operation 17 5 Configurable Parameters Settings 21 6 Obtaining Service 22 7 Troubleshooting 23 8 Replacing the Battery 24 9 Specifications 27 10 Limited product...

Страница 3: ...0 C 25 C or 68 F 77 F for at least one hour to avoid moisture condensing inside the UPS 3 CAUTION This UPS series is ONLY intended to be installed in an indoor temperature controlled environment that...

Страница 4: ...authority to operate the equipment NOTE These UPSs are shipped with the batteries disconnected The batteries must be connected before putting these UPSs into service Refer to Section 3 Installation f...

Страница 5: ...ing in the AC normal Boost and Buck modes 6 The Multi function On Off Test button is used to turn the UPS on or off or to perform a self test 7 The Fault icon illuminates when the UPS detects an inter...

Страница 6: ...ts the changes to the Configuration back to the factory default settings Must be in the Standby mode 7 Service Mode The UPS must be in the Standby mode to enter the Service mode Enter the password def...

Страница 7: ...be installed in an indoor temperature controlled environment that is free of conductive contaminants DO NOT operate the UPS in extremely dusty and or unclean areas locations near heating devices water...

Страница 8: ...FIG 1 FIG 2 13 RACKMOUNT CONFIGURATION This UPS series comes with mounting brackets for the standard 19 46 5cm rack pre installed on the UPS The mounting brackets to fit a 23 59 2cm rack and Rail Kit...

Страница 9: ...n of the UPS has been determined place the UPS on a flat surface and remove the rackmount brackets from the UPS 15 2 The LCD panel can be rotated to read in the upright position Use a small flat blade...

Страница 10: ...PTIONAL The Power Monitoring Software and interface cables can be used with the UPS Use only the interface cables that come with these UPSs Connect the interface cable Serial or USB to the appropriate...

Страница 11: ...ilenced during a general fault alarm SERVICE MODE The UPS has a Service mode function activated through the LCD screen The Service mode items are Output Voltage Adjustment Load Shedding Function Passw...

Страница 12: ...overloaded UPS will shutdown This alarm and error message will remain on until the excess load is removed or the UPS s self protection circuit shuts the UPS down If the UPS shuts down because of an O...

Страница 13: ...6 Return the unit by insured prepaid carrier to Para Systems Inc MINUTEMAN UPS 1809 W Frankford Road Suite 150 Carrollton TX 75007 ATTN RMA _______ 23 Chapter 7 Troubleshooting Symptom Error Message C...

Страница 14: ...the battery terminals 6 Determine if the battery is inadvertently grounded If the battery is remove the source of the grounding Contact with any part of a grounded battery can result in an electrical...

Страница 15: ...Acceptable Input voltage 0 165VAC 0 300VAC Voltage Range 80 164VAC 150 271VAC Frequency Limits 50 or 60 Hz 6Hz autosensing Low Voltage Transfer Point 80V 150V resets to Utility Power at 85V 157V or h...

Страница 16: ...overs faulty parts Para Systems products that are depot repaired or replaced pursuant to this warranty shall only be warranted for the unexpired portion of the warranty applying to the original produc...

Страница 17: ...Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No EXR750RT2U Y EXR1000...

Отзывы: