PARA Dox CR-R880-BL Скачать руководство пользователя страница 9

CR-R880-BL 7

Mounting on Metal

Although metal may decrease the read range, the CR-
R880-BL card reader can be mounted on metal. 
However, do not box in or surround the card reader with 
any kind of metal. If the reader must be installed in a 
metal enclosure, ensure that the face of the card reader 
is not covered and that there's at least 4cm (1.6") 
between the card reader and the metal on all sides of the 
card reader.

Wiring

Using the recommended cables listed in the technical 
specifications on page 3, splice these cables together 
with the pigtail of the reader and seal the splice. Route 
the cable from the reader to the host controller. Do not 
wire the CR-R880-BL cables in the same conduit with AC 
power cables, lock power, or signal wiring. Maintain all 
reader wiring a minimum of 30cm (12") away from other 
wiring such as: AC power, computer data wiring, 
telephone wiring, wiring to electric lock devices, etc. 
Connect the cables as shown in Figure 2 on page 10 for 
Wiegand connections, or Figure 3 on page 11 for ABA 
connections. Trim and cover all conductors.

Important Installation Notes

Do not connect the shield wires together at 
the reader cable splice. With the shield wire 
already terminated at the reader, simply 
terminate the shield at the controller. Do not 
connect the shield to the black wire at the 
reader cable splice. (refer to Figure 2 on 
page 10 and Figure 3 on page 11).

Содержание CR-R880-BL

Страница 1: ...CR R880 BL Indoor Outdoor Proximity Reader with 10cm 4in read range Installation Manual...

Страница 2: ......

Страница 3: ...Face Light 4 Audible Tone 5 Weather Resistant 5 SwiftRead 5 Diagnostic Test 5 Installation 5 Important Notes on Selecting an Installation Site 5 Mounting 6 Mounting on Metal 7 Wiring 7 Card Presentati...

Страница 4: ...ard The card will then transmit its unique identification ID number to the Indoor Outdoor Proximity Reader with 10cm 4in read range CR R880 BL After receiving the signal the reader verifies the validi...

Страница 5: ...Pulse Modulated Receive Low Frequency 12 500 KHz Receive High Frequency 15 625 KHz Operating Temperature Minimum 35 C 31 F Maximum 65 C 149 F Output Formats 26 Bit Wiegand 37 Bit Wiegand ABA Custom Ca...

Страница 6: ...BL reader includes a tricolour LED display red green and amber used to indicate the reader s status When the orange wire is pulled low the red LED will illuminate When the yellow wire is pulled low th...

Страница 7: ...L readers perform a self diagnostic test to ensure proper operation at start up and verify the integrity of the data lines Every time power is applied to the reader the green LED will flash twice to i...

Страница 8: ...otential sources of RF signal transmitters such as cellular telephones two way radios etc Mounting After selecting the appropriate mounting position for the reader use the reader s mounting plate refe...

Страница 9: ...he cable from the reader to the host controller Do not wire the CR R880 BL cables in the same conduit with AC power cables lock power or signal wiring Maintain all reader wiring a minimum of 30cm 12 a...

Страница 10: ...g an amber colour an oscillation of 1KHz is required Pull the brown wire low to activate the beeper Follow the recommended cable types and lengths listed in the technical specifications on page 3 For...

Страница 11: ...CR R880 BL 9 controller has responded accordingly To read the card again remove and re insert the card into the reader s field...

Страница 12: ...10 Installation Manual Figure 2 Wiegand Output Wiring Diagram...

Страница 13: ...CR R880 BL 11 Figure 3 ABA Output Wiring Diagram...

Страница 14: ...12 Installation Manual Dimensions Figure 4 Regular Mounting Plate...

Страница 15: ...CR R880 BL 13 Figure 5 Gang Box Mounting Plate...

Страница 16: ...l the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stol...

Страница 17: ...NOTES...

Страница 18: ......

Страница 19: ......

Страница 20: ...780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 2313 www paradox ca PRINTED IN CANADA 05 2005 CR880 EI06...