128-9108
9 of 24
Page 9
Setting Up The System Programmable Features:
Bank 1 Transmitter Programming Channels
Start with the system disarmed, turn the ignition switch to the on position then:
1) Press and release the push button valet/program switch 3 times.
Siren Chirps once and or Lights flash one time indicating the transmitter program mode
successfully entered.
See Owners Manual for transmitter programming.
Turn the ignition switch off then on to access Bank 2 Keyless / Alarm feature selec-
tions. 1 chirp +1 long chirp +1 flash then the ignition transitions off, followed by 1 long
chirp / 2 lights flashes when the key is turned on indicates that you are in feature
selection of bank 2
When the key transitions off and 2 long chirps / 3 light flashes when the key transitions
on.
Press the pushbutton switch:
1 time to access the first selection as shown below. Use the lock button of the
transmitter to change the feature selection or press the pushbutton to advance to the
next selectable feature.
Bank 2
Feature
1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash
Default
1stDoor Lock/UL 1S/1S 3.5 S/3.5S 1 S/Dbl 1 S. Dbl 1/1 S Dbl 1/Dbl 1 1S L/350mS ul
1S/1S.
2nd Accy Lock Auto Lock On Auto Lock Off
Auto Lock Off
3rd Accy. UL Auto UL On Auto UL Off
Auto UL Off
4th Horn Chirp 10mS 16mS 30mS
40mS
50mS
16mS
5
th
Chp Del TX On
Off
Off
6th Park Lights Normal On 15 Sec On 15 Sec On 15 Sec.
Normal
With Lock With U/L
w/ L & U/L
When finished setting the keyless/alarm selectable features, turn the ignition off then
on to advance to Bank 3, Remote Start Selectable Features.
1 Flash when the key transitions off and 3 chirps/light flashes when the key transitions on.
Press the pushbutton switch one time to access the first selection as shown below.
Use the lock button of the transmitter to change the feature selection or press the
pushbutton to advance to the next selectable feature.
Feature
1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash Default
1 RF Start Chirp Off On
On
2 Run Time
5 Min. 10 Min. 15Min. 20 Min. 10 Min
3 Park Lights On Steady Flash Steady
4 Input Check Voltage Tach
DBI Tach
Tach
5 Voltage Level > 0.5V B4 Start < 0.5V B4 Start
> 0.5
6 Ign. 2 Select Off With Crank On With Crank Same As Accy On With Crank
7 Diagnostics Off On
Off
8 Crank Time 0.8Sec 1.0 Sec 1.5 Sec 2.0 Sec 1.0
9 Gas/Diesel Gas Diesel 10 Diesel 15 Diesel 20 Gas
10 Green/Black Single Pulse As D/UL Pulse Single
(Aux O/P)
11 DBI Select ADS DBI
ADS
12 Time Start 2 Hours 4 Hours
4 Hours
Содержание PA-620C