TVP-2914
24
3.2
Definitions of the registers
Description of service and factory registers
Register Name Range
Description
Default
Value
01
HSh
00 63 Horizontal shift
45
02
VSD
00 00 Vertical screen
0
03
VSl
00 63 Vertical slope
30
04
VAm
00 63 Vertical amplitude
44
05
VSh
00 63 Vertical shift
32
06
SC
00 63 S-correction
14
The registers bellow
must be
set to the
default values
.
Register
Name
Range
Description
Default Value
10
TWBl
00 255 Timing of ‘wide blanking’
88
11
PWLi
00
63 Peak white limiting
08
12
OSIF
00
63 Off-set IF demodulator
20
13
HzPl
00
63 Horizontal parallelogram
32
14
HBow
00
63 Horizontal bow
32
15
HSh
00
63 Horizontal shift
45
16
EW
00
63 EW width
34
17
PW
00
63 EW parabola/width
35
18
EWUC 00
63 EW upper corner parabola
35
19
EWLC
00
63 EW lower corner parabola
35
20
TC
00
63 EW trapezium
33
21
VSl
00
63 Vertical slope
30
22
VAm
00
63 Vertical amplitude
44
23
SC
00
63 S-correction
14
24
VSh
00
63 Vertical shift
32
25
VX
00
63 Vertical zoom
25
26
VOT
00
63 Vertical Offset
28
27
TAS
00
63 Text Area Start
13
28
OEA
00 127 Odd Even Alignment
60
29
BLOR
00
63 Black level offset R
32
30
BLOG
00
63 Black level offset G
32
31
WPR
00
63 White point R
32
32
WPG
00
63 White point G
32
33
WPB
00
63 White point B
32
34
PkFr
00
3
Peaking Frequency
1
35
YDl
00
15 Luminance delay time
10
36
AGC
00
63 AGC take-over
25
37
CDc0
00
15 Colour decoder 0
6
38
CDc1
00
7
Colour decoder 1
0
39
AVS0
00 127 AV-switch 0
64
40
AVS1
00
7
AV-switch 1
0
41
Syn0
00 127 Synchronisation 0
0
42
Syn1
00
63 Synchronisation 1
16
Содержание TVP-2914
Страница 1: ...Service Manual Model TVP 2914 CODE 1 01 72434 50...
Страница 51: ......